ABAP Select data from SAP table EWASERVDYN into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP EWASERVDYN table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EWASERVDYN. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the EWASERVDYN table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_EWASERVDYN TYPE STANDARD TABLE OF EWASERVDYN, WA_EWASERVDYN TYPE EWASERVDYN, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <EWASERVDYN> TYPE EWASERVDYN. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_EWASERVDYN. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM EWASERVDYN INTO TABLE IT_EWASERVDYN. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM EWASERVDYN * INTO TABLE @DATA(IT_EWASERVDYN2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_EWASERVDYN INDEX 1 INTO DATA(WA_EWASERVDYN2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_EWASERVDYN ASSIGNING <EWASERVDYN>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<EWASERVDYN>-AUFNR = 1.
<EWASERVDYN>-ORDERCODE = 1.
<EWASERVDYN>-IHWERK = 1.
<EWASERVDYN>-TDFORMAT = 1.
<EWASERVDYN>-LONGTEXT = 1.
ENDLOOP. LOOP AT IT_EWASERVDYN INTO WA_EWASERVDYN. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_EWASERVDYN-ROUTE, sy-vline,
WA_EWASERVDYN-VORGANGDAT, sy-vline,
WA_EWASERVDYN-SERV_TYPE, sy-vline,
WA_EWASERVDYN-EORDERNR, sy-vline,
WA_EWASERVDYN-SERVICE_CAT, sy-vline,
WA_EWASERVDYN-ORDER_LAUFNR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EWASERVDYN you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EWASERVDYN TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EWASERVDYN INTO WA_EWASERVDYN. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field AUFNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EWASERVDYN-AUFNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWASERVDYN-AUFNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field ROUTE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EWASERVDYN-ROUTE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWASERVDYN-ROUTE.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field EORDERNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EWASERVDYN-EORDERNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWASERVDYN-EORDERNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field KUNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EWASERVDYN-KUNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWASERVDYN-KUNNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit TPLNR, internal->external for field SERVLOC CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_EWASERVDYN-SERVLOC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWASERVDYN-SERVLOC.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MATN1, internal->external for field BEH_TYPE CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_EWASERVDYN-BEH_TYPE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWASERVDYN-BEH_TYPE.
WRITE:/ 'New Value:', ld_input.
*Conversion exit GERNR, internal->external for field SERNR CALL FUNCTION 'CONVERSION_EXIT_GERNR_OUTPUT' EXPORTING input = WA_EWASERVDYN-SERNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWASERVDYN-SERNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field EQUNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EWASERVDYN-EQUNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWASERVDYN-EQUNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit TPLNR, internal->external for field SERVLOC_ALT CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_EWASERVDYN-SERVLOC_ALT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWASERVDYN-SERVLOC_ALT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MATN1, internal->external for field BEHTYPALT CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_EWASERVDYN-BEHTYPALT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWASERVDYN-BEHTYPALT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit GERNR, internal->external for field SERNR_ALT CALL FUNCTION 'CONVERSION_EXIT_GERNR_OUTPUT' EXPORTING input = WA_EWASERVDYN-SERNR_ALT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWASERVDYN-SERNR_ALT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MATN1, internal->external for field BEHTYPNEU CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_EWASERVDYN-BEHTYPNEU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWASERVDYN-BEHTYPNEU.
WRITE:/ 'New Value:', ld_input.
*Conversion exit GERNR, internal->external for field SERNR_NEU CALL FUNCTION 'CONVERSION_EXIT_GERNR_OUTPUT' EXPORTING input = WA_EWASERVDYN-SERNR_NEU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWASERVDYN-SERNR_NEU.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field EQUNR_ALT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EWASERVDYN-EQUNR_ALT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWASERVDYN-EQUNR_ALT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field EQUNR_NEU CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EWASERVDYN-EQUNR_NEU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWASERVDYN-EQUNR_NEU.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field REMORDERNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EWASERVDYN-REMORDERNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWASERVDYN-REMORDERNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field REMROUTE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EWASERVDYN-REMROUTE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWASERVDYN-REMROUTE.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EWASERVDYN_STR,
AUFNR TYPE STRING,
ORDERCODE TYPE STRING,
IHWERK TYPE STRING,
TDFORMAT TYPE STRING,
LONGTEXT TYPE STRING,
ROUTE TYPE STRING,
VORGANGDAT TYPE STRING,
SERV_TYPE TYPE STRING,
EORDERNR TYPE STRING,
SERVICE_CAT TYPE STRING,
ORDER_LAUFNR TYPE STRING,
KUNNR TYPE STRING,
PARTTXT TYPE STRING,
SERVLOC TYPE STRING,
LOCTXT TYPE STRING,
BEH_TYPE TYPE STRING,
SERNR TYPE STRING,
EQUNR TYPE STRING,
EADAT TYPE STRING,
EADAT_AB TYPE STRING,
SERVLOC_ALT TYPE STRING,
ANZAHL TYPE STRING,
BEHTYPALT TYPE STRING,
SERNR_ALT TYPE STRING,
ANZAHL_NEU TYPE STRING,
BEHTYPNEU TYPE STRING,
SERNR_NEU TYPE STRING,
EQUNR_ALT TYPE STRING,
EQUNR_NEU TYPE STRING,
EINBDAT TYPE STRING,
DELIVER_CONT TYPE STRING,
REMOVE_CONT TYPE STRING,
SWAP_CONT TYPE STRING,
PLDTIM TYPE STRING,
REMORDERNR TYPE STRING,
REMROUTE TYPE STRING,
REMDAT TYPE STRING,
REMTIM TYPE STRING,
REMSERVICE_TYPE TYPE STRING,END OF T_EKKO_STR. DATA: WA_EWASERVDYN_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EWASERVDYN_STR-AUFNR sy-vline
WA_EWASERVDYN_STR-ORDERCODE sy-vline
WA_EWASERVDYN_STR-IHWERK sy-vline
WA_EWASERVDYN_STR-TDFORMAT sy-vline
WA_EWASERVDYN_STR-LONGTEXT sy-vline
WA_EWASERVDYN_STR-ROUTE sy-vline
WA_EWASERVDYN_STR-VORGANGDAT sy-vline
WA_EWASERVDYN_STR-SERV_TYPE sy-vline
WA_EWASERVDYN_STR-EORDERNR sy-vline
WA_EWASERVDYN_STR-SERVICE_CAT sy-vline
WA_EWASERVDYN_STR-ORDER_LAUFNR sy-vline
WA_EWASERVDYN_STR-KUNNR sy-vline
WA_EWASERVDYN_STR-PARTTXT sy-vline
WA_EWASERVDYN_STR-SERVLOC sy-vline
WA_EWASERVDYN_STR-LOCTXT sy-vline
WA_EWASERVDYN_STR-BEH_TYPE sy-vline
WA_EWASERVDYN_STR-SERNR sy-vline
WA_EWASERVDYN_STR-EQUNR sy-vline
WA_EWASERVDYN_STR-EADAT sy-vline
WA_EWASERVDYN_STR-EADAT_AB sy-vline
WA_EWASERVDYN_STR-SERVLOC_ALT sy-vline
WA_EWASERVDYN_STR-ANZAHL sy-vline
WA_EWASERVDYN_STR-BEHTYPALT sy-vline
WA_EWASERVDYN_STR-SERNR_ALT sy-vline
WA_EWASERVDYN_STR-ANZAHL_NEU sy-vline
WA_EWASERVDYN_STR-BEHTYPNEU sy-vline
WA_EWASERVDYN_STR-SERNR_NEU sy-vline
WA_EWASERVDYN_STR-EQUNR_ALT sy-vline
WA_EWASERVDYN_STR-EQUNR_NEU sy-vline
WA_EWASERVDYN_STR-EINBDAT sy-vline
WA_EWASERVDYN_STR-DELIVER_CONT sy-vline
WA_EWASERVDYN_STR-REMOVE_CONT sy-vline
WA_EWASERVDYN_STR-SWAP_CONT sy-vline
WA_EWASERVDYN_STR-PLDTIM sy-vline
WA_EWASERVDYN_STR-REMORDERNR sy-vline
WA_EWASERVDYN_STR-REMROUTE sy-vline
WA_EWASERVDYN_STR-REMDAT sy-vline
WA_EWASERVDYN_STR-REMTIM sy-vline
WA_EWASERVDYN_STR-REMSERVICE_TYPE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.