ABAP Select data from SAP table EWASWA_MULTIWEIGHPROC_F_HD_OP into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP EWASWA_MULTIWEIGHPROC_F_HD_OP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EWASWA_MULTIWEIGHPROC_F_HD_OP. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the EWASWA_MULTIWEIGHPROC_F_HD_OP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_EWASWA_MULTIWEIGHPROC_F_HD_OP TYPE STANDARD TABLE OF EWASWA_MULTIWEIGHPROC_F_HD_OP, WA_EWASWA_MULTIWEIGHPROC_F_HD_OP TYPE EWASWA_MULTIWEIGHPROC_F_HD_OP, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <EWASWA_MULTIWEIGHPROC_F_HD_OP> TYPE EWASWA_MULTIWEIGHPROC_F_HD_OP. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_EWASWA_MULTIWEIGHPROC_F_HD_OP. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM EWASWA_MULTIWEIGHPROC_F_HD_OP INTO TABLE IT_EWASWA_MULTIWEIGHPROC_F_HD_OP. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM EWASWA_MULTIWEIGHPROC_F_HD_OP * INTO TABLE @DATA(IT_EWASWA_MULTIWEIGHPROC_F_HD_OP2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_EWASWA_MULTIWEIGHPROC_F_HD_OP INDEX 1 INTO DATA(WA_EWASWA_MULTIWEIGHPROC_F_HD_OP2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_EWASWA_MULTIWEIGHPROC_F_HD_OP ASSIGNING <EWASWA_MULTIWEIGHPROC_F_HD_OP>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<EWASWA_MULTIWEIGHPROC_F_HD_OP>-WEIGHINGNR = 1.
<EWASWA_MULTIWEIGHPROC_F_HD_OP>-LICENSE_NUM = 1.
<EWASWA_MULTIWEIGHPROC_F_HD_OP>-WDPLANTORDERTYPE = 1.
<EWASWA_MULTIWEIGHPROC_F_HD_OP>-SCHDATUM = 1.
<EWASWA_MULTIWEIGHPROC_F_HD_OP>-SCHUZEIT = 1.
ENDLOOP. LOOP AT IT_EWASWA_MULTIWEIGHPROC_F_HD_OP INTO WA_EWASWA_MULTIWEIGHPROC_F_HD_OP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_EWASWA_MULTIWEIGHPROC_F_HD_OP-PROCESSTYPE, sy-vline,
WA_EWASWA_MULTIWEIGHPROC_F_HD_OP-DELIVERYTYPE, sy-vline,
WA_EWASWA_MULTIWEIGHPROC_F_HD_OP-KUNNR, sy-vline,
WA_EWASWA_MULTIWEIGHPROC_F_HD_OP-CUSTNAME, sy-vline,
WA_EWASWA_MULTIWEIGHPROC_F_HD_OP-CUSTADDRNUM, sy-vline,
WA_EWASWA_MULTIWEIGHPROC_F_HD_OP-WEIGHINGNR_INFO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_EWASWA_MULTIWEIGHPROC_F_HD_OP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EWASWA_MULTIWEIGHPROC_F_HD_OP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EWASWA_MULTIWEIGHPROC_F_HD_OP INTO WA_EWASWA_MULTIWEIGHPROC_F_HD_OP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field WEIGHINGNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EWASWA_MULTIWEIGHPROC_F_HD_OP-WEIGHINGNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWASWA_MULTIWEIGHPROC_F_HD_OP-WEIGHINGNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field KUNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EWASWA_MULTIWEIGHPROC_F_HD_OP-KUNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWASWA_MULTIWEIGHPROC_F_HD_OP-KUNNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field CUSTADDRNUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EWASWA_MULTIWEIGHPROC_F_HD_OP-CUSTADDRNUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWASWA_MULTIWEIGHPROC_F_HD_OP-CUSTADDRNUM.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field WDPLANT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EWASWA_MULTIWEIGHPROC_F_HD_OP-WDPLANT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWASWA_MULTIWEIGHPROC_F_HD_OP-WDPLANT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field CAR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EWASWA_MULTIWEIGHPROC_F_HD_OP-CAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWASWA_MULTIWEIGHPROC_F_HD_OP-CAR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field WEIGHINGNR_EXT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EWASWA_MULTIWEIGHPROC_F_HD_OP-WEIGHINGNR_EXT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWASWA_MULTIWEIGHPROC_F_HD_OP-WEIGHINGNR_EXT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field ORDERNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EWASWA_MULTIWEIGHPROC_F_HD_OP-ORDERNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWASWA_MULTIWEIGHPROC_F_HD_OP-ORDERNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field CONTRACT_VBELN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EWASWA_MULTIWEIGHPROC_F_HD_OP-CONTRACT_VBELN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWASWA_MULTIWEIGHPROC_F_HD_OP-CONTRACT_VBELN.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EWASWA_MULTIWEIGHPROC_F_HD_OP_STR,
WEIGHINGNR TYPE STRING,
LICENSE_NUM TYPE STRING,
WDPLANTORDERTYPE TYPE STRING,
SCHDATUM TYPE STRING,
SCHUZEIT TYPE STRING,
PROCESSTYPE TYPE STRING,
DELIVERYTYPE TYPE STRING,
KUNNR TYPE STRING,
CUSTNAME TYPE STRING,
CUSTADDRNUM TYPE STRING,
WEIGHINGNR_INFO TYPE STRING,
WEIGHINGNR_TYPE TYPE STRING,
WDPLANT TYPE STRING,
CAR TYPE STRING,
WEIGHINGNR_EXT TYPE STRING,
YARDCHECKSTATUS_INFO TYPE STRING,
ORDERNR TYPE STRING,
POBJNR TYPE STRING,
CONTRACT_VBELN TYPE STRING,
CONTRACT_POSNR TYPE STRING,END OF T_EKKO_STR. DATA: WA_EWASWA_MULTIWEIGHPROC_F_HD_OP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EWASWA_MULTIWEIGHPROC_F_HD_OP_STR-WEIGHINGNR sy-vline
WA_EWASWA_MULTIWEIGHPROC_F_HD_OP_STR-LICENSE_NUM sy-vline
WA_EWASWA_MULTIWEIGHPROC_F_HD_OP_STR-WDPLANTORDERTYPE sy-vline
WA_EWASWA_MULTIWEIGHPROC_F_HD_OP_STR-SCHDATUM sy-vline
WA_EWASWA_MULTIWEIGHPROC_F_HD_OP_STR-SCHUZEIT sy-vline
WA_EWASWA_MULTIWEIGHPROC_F_HD_OP_STR-PROCESSTYPE sy-vline
WA_EWASWA_MULTIWEIGHPROC_F_HD_OP_STR-DELIVERYTYPE sy-vline
WA_EWASWA_MULTIWEIGHPROC_F_HD_OP_STR-KUNNR sy-vline
WA_EWASWA_MULTIWEIGHPROC_F_HD_OP_STR-CUSTNAME sy-vline
WA_EWASWA_MULTIWEIGHPROC_F_HD_OP_STR-CUSTADDRNUM sy-vline
WA_EWASWA_MULTIWEIGHPROC_F_HD_OP_STR-WEIGHINGNR_INFO sy-vline
WA_EWASWA_MULTIWEIGHPROC_F_HD_OP_STR-WEIGHINGNR_TYPE sy-vline
WA_EWASWA_MULTIWEIGHPROC_F_HD_OP_STR-WDPLANT sy-vline
WA_EWASWA_MULTIWEIGHPROC_F_HD_OP_STR-CAR sy-vline
WA_EWASWA_MULTIWEIGHPROC_F_HD_OP_STR-WEIGHINGNR_EXT sy-vline
WA_EWASWA_MULTIWEIGHPROC_F_HD_OP_STR-YARDCHECKSTATUS_INFO sy-vline
WA_EWASWA_MULTIWEIGHPROC_F_HD_OP_STR-ORDERNR sy-vline
WA_EWASWA_MULTIWEIGHPROC_F_HD_OP_STR-POBJNR sy-vline
WA_EWASWA_MULTIWEIGHPROC_F_HD_OP_STR-CONTRACT_VBELN sy-vline
WA_EWASWA_MULTIWEIGHPROC_F_HD_OP_STR-CONTRACT_POSNR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.