ABAP Select data from SAP table EWM_MU_I10_MRTRANS into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP EWM_MU_I10_MRTRANS table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to EWM_MU_I10_MRTRANS. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the EWM_MU_I10_MRTRANS table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_EWM_MU_I10_MRTRANS TYPE STANDARD TABLE OF EWM_MU_I10_MRTRANS, WA_EWM_MU_I10_MRTRANS TYPE EWM_MU_I10_MRTRANS, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <EWM_MU_I10_MRTRANS> TYPE EWM_MU_I10_MRTRANS. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_EWM_MU_I10_MRTRANS. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM EWM_MU_I10_MRTRANS INTO TABLE IT_EWM_MU_I10_MRTRANS. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM EWM_MU_I10_MRTRANS * INTO TABLE @DATA(IT_EWM_MU_I10_MRTRANS2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_EWM_MU_I10_MRTRANS INDEX 1 INTO DATA(WA_EWM_MU_I10_MRTRANS2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_EWM_MU_I10_MRTRANS ASSIGNING <EWM_MU_I10_MRTRANS>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<EWM_MU_I10_MRTRANS>-EQUNRNEU = 1.
<EWM_MU_I10_MRTRANS>-MATNR = 1.
<EWM_MU_I10_MRTRANS>-GERAETNEU = 1.
<EWM_MU_I10_MRTRANS>-WANDNR = 1.
<EWM_MU_I10_MRTRANS>-WAND_MATNR = 1.
ENDLOOP. LOOP AT IT_EWM_MU_I10_MRTRANS INTO WA_EWM_MU_I10_MRTRANS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, ENDLOOP. *Add any further fields from structure WA_EWM_MU_I10_MRTRANS you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_EWM_MU_I10_MRTRANS TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_EWM_MU_I10_MRTRANS INTO WA_EWM_MU_I10_MRTRANS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field EQUNRNEU CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_EWM_MU_I10_MRTRANS-EQUNRNEU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWM_MU_I10_MRTRANS-EQUNRNEU.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_EWM_MU_I10_MRTRANS-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWM_MU_I10_MRTRANS-MATNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit GERNR, internal->external for field GERAETNEU CALL FUNCTION 'CONVERSION_EXIT_GERNR_OUTPUT' EXPORTING input = WA_EWM_MU_I10_MRTRANS-GERAETNEU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWM_MU_I10_MRTRANS-GERAETNEU.
WRITE:/ 'New Value:', ld_input.
*Conversion exit GERNR, internal->external for field WANDNR CALL FUNCTION 'CONVERSION_EXIT_GERNR_OUTPUT' EXPORTING input = WA_EWM_MU_I10_MRTRANS-WANDNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWM_MU_I10_MRTRANS-WANDNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MATN1, internal->external for field WAND_MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_EWM_MU_I10_MRTRANS-WAND_MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_EWM_MU_I10_MRTRANS-WAND_MATNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_EWM_MU_I10_MRTRANS_STR,
EQUNRNEU TYPE STRING,
MATNR TYPE STRING,
GERAETNEU TYPE STRING,
WANDNR TYPE STRING,
WAND_MATNR TYPE STRING,END OF T_EKKO_STR. DATA: WA_EWM_MU_I10_MRTRANS_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_EWM_MU_I10_MRTRANS_STR-EQUNRNEU sy-vline
WA_EWM_MU_I10_MRTRANS_STR-MATNR sy-vline
WA_EWM_MU_I10_MRTRANS_STR-GERAETNEU sy-vline
WA_EWM_MU_I10_MRTRANS_STR-WANDNR sy-vline
WA_EWM_MU_I10_MRTRANS_STR-WAND_MATNR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.