ABAP Select data from SAP table FAA_DC_S_PROCESSING_INFO_720 into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP FAA_DC_S_PROCESSING_INFO_720 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FAA_DC_S_PROCESSING_INFO_720. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the FAA_DC_S_PROCESSING_INFO_720 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_FAA_DC_S_PROCESSING_INFO_720 TYPE STANDARD TABLE OF FAA_DC_S_PROCESSING_INFO_720, WA_FAA_DC_S_PROCESSING_INFO_720 TYPE FAA_DC_S_PROCESSING_INFO_720, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <FAA_DC_S_PROCESSING_INFO_720> TYPE FAA_DC_S_PROCESSING_INFO_720. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_FAA_DC_S_PROCESSING_INFO_720. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM FAA_DC_S_PROCESSING_INFO_720 INTO TABLE IT_FAA_DC_S_PROCESSING_INFO_720. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM FAA_DC_S_PROCESSING_INFO_720 * INTO TABLE @DATA(IT_FAA_DC_S_PROCESSING_INFO_7202). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_FAA_DC_S_PROCESSING_INFO_720 INDEX 1 INTO DATA(WA_FAA_DC_S_PROCESSING_INFO_7202). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_FAA_DC_S_PROCESSING_INFO_720 ASSIGNING <FAA_DC_S_PROCESSING_INFO_720>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<FAA_DC_S_PROCESSING_INFO_720>-FYEAR = 1.
<FAA_DC_S_PROCESSING_INFO_720>-FYEAR_TO = 1.
<FAA_DC_S_PROCESSING_INFO_720>-PERIOD_OFFSET = 1.
<FAA_DC_S_PROCESSING_INFO_720>-PERIOD_OFFSET_LAST_YR = 1.
<FAA_DC_S_PROCESSING_INFO_720>-CALC_CLOSED_YEARS = 1.
ENDLOOP. LOOP AT IT_FAA_DC_S_PROCESSING_INFO_720 INTO WA_FAA_DC_S_PROCESSING_INFO_720. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_FAA_DC_S_PROCESSING_INFO_720-CALC_ONLY_EXP_ULIFE, sy-vline,
WA_FAA_DC_S_PROCESSING_INFO_720-GET_PARALLEL_CURRENCIES, sy-vline,
WA_FAA_DC_S_PROCESSING_INFO_720-GET_BCF_VALUES, sy-vline,
WA_FAA_DC_S_PROCESSING_INFO_720-WRITE_TRACE, sy-vline,
WA_FAA_DC_S_PROCESSING_INFO_720-PROCESS, sy-vline,
WA_FAA_DC_S_PROCESSING_INFO_720-STEP, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FAA_DC_S_PROCESSING_INFO_720 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FAA_DC_S_PROCESSING_INFO_720 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FAA_DC_S_PROCESSING_INFO_720 INTO WA_FAA_DC_S_PROCESSING_INFO_720. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit GJAHR, internal->external for field FYEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_FAA_DC_S_PROCESSING_INFO_720-FYEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FAA_DC_S_PROCESSING_INFO_720-FYEAR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit GJAHR, internal->external for field FYEAR_TO CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_FAA_DC_S_PROCESSING_INFO_720-FYEAR_TO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FAA_DC_S_PROCESSING_INFO_720-FYEAR_TO.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FAA_DC_S_PROCESSING_INFO_720_STR,
FYEAR TYPE STRING,
FYEAR_TO TYPE STRING,
PERIOD_OFFSET TYPE STRING,
PERIOD_OFFSET_LAST_YR TYPE STRING,
CALC_CLOSED_YEARS TYPE STRING,
CALC_ONLY_EXP_ULIFE TYPE STRING,
GET_PARALLEL_CURRENCIES TYPE STRING,
GET_BCF_VALUES TYPE STRING,
WRITE_TRACE TYPE STRING,
PROCESS TYPE STRING,
STEP TYPE STRING,
LDGRP TYPE STRING,
T_AREA TYPE STRING,
LEADOBJ_INSTANCE TYPE STRING,
POSTING_INSTANCE TYPE STRING,END OF T_EKKO_STR. DATA: WA_FAA_DC_S_PROCESSING_INFO_720_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FAA_DC_S_PROCESSING_INFO_720_STR-FYEAR sy-vline
WA_FAA_DC_S_PROCESSING_INFO_720_STR-FYEAR_TO sy-vline
WA_FAA_DC_S_PROCESSING_INFO_720_STR-PERIOD_OFFSET sy-vline
WA_FAA_DC_S_PROCESSING_INFO_720_STR-PERIOD_OFFSET_LAST_YR sy-vline
WA_FAA_DC_S_PROCESSING_INFO_720_STR-CALC_CLOSED_YEARS sy-vline
WA_FAA_DC_S_PROCESSING_INFO_720_STR-CALC_ONLY_EXP_ULIFE sy-vline
WA_FAA_DC_S_PROCESSING_INFO_720_STR-GET_PARALLEL_CURRENCIES sy-vline
WA_FAA_DC_S_PROCESSING_INFO_720_STR-GET_BCF_VALUES sy-vline
WA_FAA_DC_S_PROCESSING_INFO_720_STR-WRITE_TRACE sy-vline
WA_FAA_DC_S_PROCESSING_INFO_720_STR-PROCESS sy-vline
WA_FAA_DC_S_PROCESSING_INFO_720_STR-STEP sy-vline
WA_FAA_DC_S_PROCESSING_INFO_720_STR-LDGRP sy-vline
WA_FAA_DC_S_PROCESSING_INFO_720_STR-T_AREA sy-vline
WA_FAA_DC_S_PROCESSING_INFO_720_STR-LEADOBJ_INSTANCE sy-vline
WA_FAA_DC_S_PROCESSING_INFO_720_STR-POSTING_INSTANCE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.