ABAP Select data from SAP table FAC_S_WUPC_PCG_INFO into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP FAC_S_WUPC_PCG_INFO table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FAC_S_WUPC_PCG_INFO. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the FAC_S_WUPC_PCG_INFO table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_FAC_S_WUPC_PCG_INFO TYPE STANDARD TABLE OF FAC_S_WUPC_PCG_INFO, WA_FAC_S_WUPC_PCG_INFO TYPE FAC_S_WUPC_PCG_INFO, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <FAC_S_WUPC_PCG_INFO> TYPE FAC_S_WUPC_PCG_INFO. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_FAC_S_WUPC_PCG_INFO. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM FAC_S_WUPC_PCG_INFO INTO TABLE IT_FAC_S_WUPC_PCG_INFO. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM FAC_S_WUPC_PCG_INFO * INTO TABLE @DATA(IT_FAC_S_WUPC_PCG_INFO2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_FAC_S_WUPC_PCG_INFO INDEX 1 INTO DATA(WA_FAC_S_WUPC_PCG_INFO2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_FAC_S_WUPC_PCG_INFO ASSIGNING <FAC_S_WUPC_PCG_INFO>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<FAC_S_WUPC_PCG_INFO>-CONTEXT = 1.
<FAC_S_WUPC_PCG_INFO>-CONTROLLINGAREA = 1.
<FAC_S_WUPC_PCG_INFO>-PROFITCENTER = 1.
<FAC_S_WUPC_PCG_INFO>-PROFITCENTERNAME = 1.
<FAC_S_WUPC_PCG_INFO>-PROFITCENTERGROUP = 1.
ENDLOOP. LOOP AT IT_FAC_S_WUPC_PCG_INFO INTO WA_FAC_S_WUPC_PCG_INFO. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_FAC_S_WUPC_PCG_INFO-PROFITCENTERGROUPNAME, sy-vline,
WA_FAC_S_WUPC_PCG_INFO-CHILDSETID, sy-vline,
WA_FAC_S_WUPC_PCG_INFO-PROFITCENTERSTANDARDHIERARCHY, sy-vline,
WA_FAC_S_WUPC_PCG_INFO-CREATEDBYUSER, sy-vline,
WA_FAC_S_WUPC_PCG_INFO-CREATIONDATE, sy-vline,
WA_FAC_S_WUPC_PCG_INFO-CREATIONTIME, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FAC_S_WUPC_PCG_INFO you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FAC_S_WUPC_PCG_INFO TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FAC_S_WUPC_PCG_INFO INTO WA_FAC_S_WUPC_PCG_INFO. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field PROFITCENTER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FAC_S_WUPC_PCG_INFO-PROFITCENTER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FAC_S_WUPC_PCG_INFO-PROFITCENTER.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FAC_S_WUPC_PCG_INFO_STR,
CONTEXT TYPE STRING,
CONTROLLINGAREA TYPE STRING,
PROFITCENTER TYPE STRING,
PROFITCENTERNAME TYPE STRING,
PROFITCENTERGROUP TYPE STRING,
PROFITCENTERGROUPNAME TYPE STRING,
CHILDSETID TYPE STRING,
PROFITCENTERSTANDARDHIERARCHY TYPE STRING,
CREATEDBYUSER TYPE STRING,
CREATIONDATE TYPE STRING,
CREATIONTIME TYPE STRING,
LASTCHANGEDBYUSER TYPE STRING,
LASTCHANGEDDATE TYPE STRING,
LASTCHANGETIME TYPE STRING,
VALIDITYSTARTDATE TYPE STRING,
VALIDITYENDDATE TYPE STRING,
FINDIN TYPE STRING,END OF T_EKKO_STR. DATA: WA_FAC_S_WUPC_PCG_INFO_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FAC_S_WUPC_PCG_INFO_STR-CONTEXT sy-vline
WA_FAC_S_WUPC_PCG_INFO_STR-CONTROLLINGAREA sy-vline
WA_FAC_S_WUPC_PCG_INFO_STR-PROFITCENTER sy-vline
WA_FAC_S_WUPC_PCG_INFO_STR-PROFITCENTERNAME sy-vline
WA_FAC_S_WUPC_PCG_INFO_STR-PROFITCENTERGROUP sy-vline
WA_FAC_S_WUPC_PCG_INFO_STR-PROFITCENTERGROUPNAME sy-vline
WA_FAC_S_WUPC_PCG_INFO_STR-CHILDSETID sy-vline
WA_FAC_S_WUPC_PCG_INFO_STR-PROFITCENTERSTANDARDHIERARCHY sy-vline
WA_FAC_S_WUPC_PCG_INFO_STR-CREATEDBYUSER sy-vline
WA_FAC_S_WUPC_PCG_INFO_STR-CREATIONDATE sy-vline
WA_FAC_S_WUPC_PCG_INFO_STR-CREATIONTIME sy-vline
WA_FAC_S_WUPC_PCG_INFO_STR-LASTCHANGEDBYUSER sy-vline
WA_FAC_S_WUPC_PCG_INFO_STR-LASTCHANGEDDATE sy-vline
WA_FAC_S_WUPC_PCG_INFO_STR-LASTCHANGETIME sy-vline
WA_FAC_S_WUPC_PCG_INFO_STR-VALIDITYSTARTDATE sy-vline
WA_FAC_S_WUPC_PCG_INFO_STR-VALIDITYENDDATE sy-vline
WA_FAC_S_WUPC_PCG_INFO_STR-FINDIN sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.