ABAP Select data from SAP table FAGLSKF_PN into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP FAGLSKF_PN table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FAGLSKF_PN. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the FAGLSKF_PN table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_FAGLSKF_PN TYPE STANDARD TABLE OF FAGLSKF_PN, WA_FAGLSKF_PN TYPE FAGLSKF_PN, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <FAGLSKF_PN> TYPE FAGLSKF_PN. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_FAGLSKF_PN. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM FAGLSKF_PN INTO TABLE IT_FAGLSKF_PN. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM FAGLSKF_PN * INTO TABLE @DATA(IT_FAGLSKF_PN2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_FAGLSKF_PN INDEX 1 INTO DATA(WA_FAGLSKF_PN2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_FAGLSKF_PN ASSIGNING <FAGLSKF_PN>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<FAGLSKF_PN>-RCLNT = 1.
<FAGLSKF_PN>-STAGR = 1.
<FAGLSKF_PN>-DATE_FROM = 1.
<FAGLSKF_PN>-DOCNR = 1.
<FAGLSKF_PN>-DOCLN = 1.
ENDLOOP. LOOP AT IT_FAGLSKF_PN INTO WA_FAGLSKF_PN. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_FAGLSKF_PN-DATE_TO, sy-vline,
WA_FAGLSKF_PN-RBUKRS, sy-vline,
WA_FAGLSKF_PN-RCNTR, sy-vline,
WA_FAGLSKF_PN-PRCTR, sy-vline,
WA_FAGLSKF_PN-RFAREA, sy-vline,
WA_FAGLSKF_PN-RBUSA, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FAGLSKF_PN you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FAGLSKF_PN TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FAGLSKF_PN INTO WA_FAGLSKF_PN. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field DOCNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FAGLSKF_PN-DOCNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FAGLSKF_PN-DOCNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field RCNTR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FAGLSKF_PN-RCNTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FAGLSKF_PN-RCNTR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field PRCTR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FAGLSKF_PN-PRCTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FAGLSKF_PN-PRCTR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field SEGMENT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FAGLSKF_PN-SEGMENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FAGLSKF_PN-SEGMENT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field RUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_FAGLSKF_PN-RUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FAGLSKF_PN-RUNIT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field LOGSYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FAGLSKF_PN-LOGSYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FAGLSKF_PN-LOGSYS.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field RVERS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FAGLSKF_PN-RVERS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FAGLSKF_PN-RVERS.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field REFDOCNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FAGLSKF_PN-REFDOCNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FAGLSKF_PN-REFDOCNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field CANC_DOCNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FAGLSKF_PN-CANC_DOCNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FAGLSKF_PN-CANC_DOCNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FAGLSKF_PN_STR,
RCLNT TYPE STRING,
STAGR TYPE STRING,
DATE_FROM TYPE STRING,
DOCNR TYPE STRING,
DOCLN TYPE STRING,
DATE_TO TYPE STRING,
RBUKRS TYPE STRING,
RCNTR TYPE STRING,
PRCTR TYPE STRING,
RFAREA TYPE STRING,
RBUSA TYPE STRING,
KOKRS TYPE STRING,
SEGMENT TYPE STRING,
ACTIV TYPE STRING,
OBART TYPE STRING,
RUNIT TYPE STRING,
LOGSYS TYPE STRING,
RRCTY TYPE STRING,
RVERS TYPE STRING,
MSL TYPE STRING,
REFDOCNR TYPE STRING,
CANC_DOCNR TYPE STRING,
USNAM TYPE STRING,
TIMESTAMP TYPE STRING,
DELTA_IND TYPE STRING,END OF T_EKKO_STR. DATA: WA_FAGLSKF_PN_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FAGLSKF_PN_STR-RCLNT sy-vline
WA_FAGLSKF_PN_STR-STAGR sy-vline
WA_FAGLSKF_PN_STR-DATE_FROM sy-vline
WA_FAGLSKF_PN_STR-DOCNR sy-vline
WA_FAGLSKF_PN_STR-DOCLN sy-vline
WA_FAGLSKF_PN_STR-DATE_TO sy-vline
WA_FAGLSKF_PN_STR-RBUKRS sy-vline
WA_FAGLSKF_PN_STR-RCNTR sy-vline
WA_FAGLSKF_PN_STR-PRCTR sy-vline
WA_FAGLSKF_PN_STR-RFAREA sy-vline
WA_FAGLSKF_PN_STR-RBUSA sy-vline
WA_FAGLSKF_PN_STR-KOKRS sy-vline
WA_FAGLSKF_PN_STR-SEGMENT sy-vline
WA_FAGLSKF_PN_STR-ACTIV sy-vline
WA_FAGLSKF_PN_STR-OBART sy-vline
WA_FAGLSKF_PN_STR-RUNIT sy-vline
WA_FAGLSKF_PN_STR-LOGSYS sy-vline
WA_FAGLSKF_PN_STR-RRCTY sy-vline
WA_FAGLSKF_PN_STR-RVERS sy-vline
WA_FAGLSKF_PN_STR-MSL sy-vline
WA_FAGLSKF_PN_STR-REFDOCNR sy-vline
WA_FAGLSKF_PN_STR-CANC_DOCNR sy-vline
WA_FAGLSKF_PN_STR-USNAM sy-vline
WA_FAGLSKF_PN_STR-TIMESTAMP sy-vline
WA_FAGLSKF_PN_STR-DELTA_IND sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.