ABAP Select data from SAP table FARR_S_ICMI03_BASIC into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FARR_S_ICMI03_BASIC table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FARR_S_ICMI03_BASIC. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FARR_S_ICMI03_BASIC table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FARR_S_ICMI03_BASIC TYPE STANDARD TABLE OF FARR_S_ICMI03_BASIC,
      WA_FARR_S_ICMI03_BASIC TYPE FARR_S_ICMI03_BASIC,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FARR_S_ICMI03_BASIC> TYPE FARR_S_ICMI03_BASIC.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FARR_S_ICMI03_BASIC.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FARR_S_ICMI03_BASIC
  INTO TABLE IT_FARR_S_ICMI03_BASIC.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FARR_S_ICMI03_BASIC
*  INTO TABLE @DATA(IT_FARR_S_ICMI03_BASIC2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FARR_S_ICMI03_BASIC INDEX 1 INTO DATA(WA_FARR_S_ICMI03_BASIC2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FARR_S_ICMI03_BASIC ASSIGNING <FARR_S_ICMI03_BASIC>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FARR_S_ICMI03_BASIC>-KUNNR = 1.
<FARR_S_ICMI03_BASIC>-PARTNER = 1.
<FARR_S_ICMI03_BASIC>-WAERS = 1.
<FARR_S_ICMI03_BASIC>-HWAER = 1.
<FARR_S_ICMI03_BASIC>-HWAE2 = 1.
ENDLOOP.

LOOP AT IT_FARR_S_ICMI03_BASIC INTO WA_FARR_S_ICMI03_BASIC.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FARR_S_ICMI03_BASIC-HWAE3, sy-vline,
WA_FARR_S_ICMI03_BASIC-QUANTITY_REL, sy-vline,
WA_FARR_S_ICMI03_BASIC-FINAL_INVOICE, sy-vline,
WA_FARR_S_ICMI03_BASIC-ORIGDOC_COMP, sy-vline,
WA_FARR_S_ICMI03_BASIC-ORIGDOC_LOGSYS, sy-vline,
WA_FARR_S_ICMI03_BASIC-ORIGDOC_TYPE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FARR_S_ICMI03_BASIC you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FARR_S_ICMI03_BASIC TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FARR_S_ICMI03_BASIC INTO WA_FARR_S_ICMI03_BASIC. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field KUNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FARR_S_ICMI03_BASIC-KUNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FARR_S_ICMI03_BASIC-KUNNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PARTNER CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FARR_S_ICMI03_BASIC-PARTNER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FARR_S_ICMI03_BASIC-PARTNER.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field ORIGDOC_LOGSYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FARR_S_ICMI03_BASIC-ORIGDOC_LOGSYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FARR_S_ICMI03_BASIC-ORIGDOC_LOGSYS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXCRT, internal->external for field EXCHANGE_RATE CALL FUNCTION 'CONVERSION_EXIT_EXCRT_OUTPUT' EXPORTING input = WA_FARR_S_ICMI03_BASIC-EXCHANGE_RATE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FARR_S_ICMI03_BASIC-EXCHANGE_RATE.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXCRT, internal->external for field EXCHANGE_RATE2 CALL FUNCTION 'CONVERSION_EXIT_EXCRT_OUTPUT' EXPORTING input = WA_FARR_S_ICMI03_BASIC-EXCHANGE_RATE2 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FARR_S_ICMI03_BASIC-EXCHANGE_RATE2.
WRITE:/ 'New Value:', ld_input.

*Conversion exit EXCRT, internal->external for field EXCHANGE_RATE3 CALL FUNCTION 'CONVERSION_EXIT_EXCRT_OUTPUT' EXPORTING input = WA_FARR_S_ICMI03_BASIC-EXCHANGE_RATE3 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FARR_S_ICMI03_BASIC-EXCHANGE_RATE3.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PINV_LOGSYS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FARR_S_ICMI03_BASIC-PINV_LOGSYS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FARR_S_ICMI03_BASIC-PINV_LOGSYS.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FARR_S_ICMI03_BASIC_STR,
KUNNR TYPE STRING,
PARTNER TYPE STRING,
WAERS TYPE STRING,
HWAER TYPE STRING,
HWAE2 TYPE STRING,
HWAE3 TYPE STRING,
QUANTITY_REL TYPE STRING,
FINAL_INVOICE TYPE STRING,
ORIGDOC_COMP TYPE STRING,
ORIGDOC_LOGSYS TYPE STRING,
ORIGDOC_TYPE TYPE STRING,
ORIGDOC_ID TYPE STRING,
DUE_DATE TYPE STRING,
POSTING_DATE TYPE STRING,
REVERSAL TYPE STRING,
INVOICE_TYPE TYPE STRING,
EXCHANGE_RATE TYPE STRING,
EXCHANGE_RATE2 TYPE STRING,
EXCHANGE_RATE3 TYPE STRING,
INVOICE_CAT TYPE STRING,
PINV_COMP TYPE STRING,
PINV_LOGSYS TYPE STRING,
PINV_TYPE TYPE STRING,
PINV_ID TYPE STRING,
DELETION_IND TYPE STRING,
BLDAT TYPE STRING,
WWERT TYPE STRING,
XWAERS_CONVERT TYPE STRING,END OF T_EKKO_STR. DATA: WA_FARR_S_ICMI03_BASIC_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FARR_S_ICMI03_BASIC_STR-KUNNR sy-vline
WA_FARR_S_ICMI03_BASIC_STR-PARTNER sy-vline
WA_FARR_S_ICMI03_BASIC_STR-WAERS sy-vline
WA_FARR_S_ICMI03_BASIC_STR-HWAER sy-vline
WA_FARR_S_ICMI03_BASIC_STR-HWAE2 sy-vline
WA_FARR_S_ICMI03_BASIC_STR-HWAE3 sy-vline
WA_FARR_S_ICMI03_BASIC_STR-QUANTITY_REL sy-vline
WA_FARR_S_ICMI03_BASIC_STR-FINAL_INVOICE sy-vline
WA_FARR_S_ICMI03_BASIC_STR-ORIGDOC_COMP sy-vline
WA_FARR_S_ICMI03_BASIC_STR-ORIGDOC_LOGSYS sy-vline
WA_FARR_S_ICMI03_BASIC_STR-ORIGDOC_TYPE sy-vline
WA_FARR_S_ICMI03_BASIC_STR-ORIGDOC_ID sy-vline
WA_FARR_S_ICMI03_BASIC_STR-DUE_DATE sy-vline
WA_FARR_S_ICMI03_BASIC_STR-POSTING_DATE sy-vline
WA_FARR_S_ICMI03_BASIC_STR-REVERSAL sy-vline
WA_FARR_S_ICMI03_BASIC_STR-INVOICE_TYPE sy-vline
WA_FARR_S_ICMI03_BASIC_STR-EXCHANGE_RATE sy-vline
WA_FARR_S_ICMI03_BASIC_STR-EXCHANGE_RATE2 sy-vline
WA_FARR_S_ICMI03_BASIC_STR-EXCHANGE_RATE3 sy-vline
WA_FARR_S_ICMI03_BASIC_STR-INVOICE_CAT sy-vline
WA_FARR_S_ICMI03_BASIC_STR-PINV_COMP sy-vline
WA_FARR_S_ICMI03_BASIC_STR-PINV_LOGSYS sy-vline
WA_FARR_S_ICMI03_BASIC_STR-PINV_TYPE sy-vline
WA_FARR_S_ICMI03_BASIC_STR-PINV_ID sy-vline
WA_FARR_S_ICMI03_BASIC_STR-DELETION_IND sy-vline
WA_FARR_S_ICMI03_BASIC_STR-BLDAT sy-vline
WA_FARR_S_ICMI03_BASIC_STR-WWERT sy-vline
WA_FARR_S_ICMI03_BASIC_STR-XWAERS_CONVERT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.