ABAP Select data from SAP table FBVV_ROC_DEVAL into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP FBVV_ROC_DEVAL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FBVV_ROC_DEVAL. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the FBVV_ROC_DEVAL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_FBVV_ROC_DEVAL TYPE STANDARD TABLE OF FBVV_ROC_DEVAL, WA_FBVV_ROC_DEVAL TYPE FBVV_ROC_DEVAL, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <FBVV_ROC_DEVAL> TYPE FBVV_ROC_DEVAL. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_FBVV_ROC_DEVAL. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM FBVV_ROC_DEVAL INTO TABLE IT_FBVV_ROC_DEVAL. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM FBVV_ROC_DEVAL * INTO TABLE @DATA(IT_FBVV_ROC_DEVAL2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_FBVV_ROC_DEVAL INDEX 1 INTO DATA(WA_FBVV_ROC_DEVAL2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_FBVV_ROC_DEVAL ASSIGNING <FBVV_ROC_DEVAL>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<FBVV_ROC_DEVAL>-MANDT = 1.
<FBVV_ROC_DEVAL>-ACC_PRINCIPLE = 1.
<FBVV_ROC_DEVAL>-RLDNR = 1.
<FBVV_ROC_DEVAL>-BWKEY = 1.
<FBVV_ROC_DEVAL>-BUKRS = 1.
ENDLOOP. LOOP AT IT_FBVV_ROC_DEVAL INTO WA_FBVV_ROC_DEVAL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_FBVV_ROC_DEVAL-BKLAS, sy-vline,
WA_FBVV_ROC_DEVAL-MTART, sy-vline,
WA_FBVV_ROC_DEVAL-RNGE_OF_CVRG, sy-vline,
WA_FBVV_ROC_DEVAL-DEVAL_PRC, sy-vline,
WA_FBVV_ROC_DEVAL-INACTIVE_INDICATOR, sy-vline,
WA_FBVV_ROC_DEVAL-BUTXT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FBVV_ROC_DEVAL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FBVV_ROC_DEVAL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FBVV_ROC_DEVAL INTO WA_FBVV_ROC_DEVAL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field RLDNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FBVV_ROC_DEVAL-RLDNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FBVV_ROC_DEVAL-RLDNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FBVV_ROC_DEVAL_STR,
MANDT TYPE STRING,
ACC_PRINCIPLE TYPE STRING,
RLDNR TYPE STRING,
BWKEY TYPE STRING,
BUKRS TYPE STRING,
BKLAS TYPE STRING,
MTART TYPE STRING,
RNGE_OF_CVRG TYPE STRING,
DEVAL_PRC TYPE STRING,
INACTIVE_INDICATOR TYPE STRING,
BUTXT TYPE STRING,
MTBEZ TYPE STRING,
BKBEZ TYPE STRING,
ACC_PRINCTXT TYPE STRING,END OF T_EKKO_STR. DATA: WA_FBVV_ROC_DEVAL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FBVV_ROC_DEVAL_STR-MANDT sy-vline
WA_FBVV_ROC_DEVAL_STR-ACC_PRINCIPLE sy-vline
WA_FBVV_ROC_DEVAL_STR-RLDNR sy-vline
WA_FBVV_ROC_DEVAL_STR-BWKEY sy-vline
WA_FBVV_ROC_DEVAL_STR-BUKRS sy-vline
WA_FBVV_ROC_DEVAL_STR-BKLAS sy-vline
WA_FBVV_ROC_DEVAL_STR-MTART sy-vline
WA_FBVV_ROC_DEVAL_STR-RNGE_OF_CVRG sy-vline
WA_FBVV_ROC_DEVAL_STR-DEVAL_PRC sy-vline
WA_FBVV_ROC_DEVAL_STR-INACTIVE_INDICATOR sy-vline
WA_FBVV_ROC_DEVAL_STR-BUTXT sy-vline
WA_FBVV_ROC_DEVAL_STR-MTBEZ sy-vline
WA_FBVV_ROC_DEVAL_STR-BKBEZ sy-vline
WA_FBVV_ROC_DEVAL_STR-ACC_PRINCTXT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.