ABAP Select data from SAP table FC00_S_FICLST30SCR into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP FC00_S_FICLST30SCR table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FC00_S_FICLST30SCR. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the FC00_S_FICLST30SCR table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_FC00_S_FICLST30SCR TYPE STANDARD TABLE OF FC00_S_FICLST30SCR, WA_FC00_S_FICLST30SCR TYPE FC00_S_FICLST30SCR, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <FC00_S_FICLST30SCR> TYPE FC00_S_FICLST30SCR. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_FC00_S_FICLST30SCR. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM FC00_S_FICLST30SCR INTO TABLE IT_FC00_S_FICLST30SCR. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM FC00_S_FICLST30SCR * INTO TABLE @DATA(IT_FC00_S_FICLST30SCR2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_FC00_S_FICLST30SCR INDEX 1 INTO DATA(WA_FC00_S_FICLST30SCR2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_FC00_S_FICLST30SCR ASSIGNING <FC00_S_FICLST30SCR>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<FC00_S_FICLST30SCR>-MANDT = 1.
<FC00_S_FICLST30SCR>-RDIMEN = 1.
<FC00_S_FICLST30SCR>-RLDNR = 1.
<FC00_S_FICLST30SCR>-RCONGR = 1.
<FC00_S_FICLST30SCR>-RBUNIT = 1.
ENDLOOP. LOOP AT IT_FC00_S_FICLST30SCR INTO WA_FC00_S_FICLST30SCR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_FC00_S_FICLST30SCR-RITCLG, sy-vline,
WA_FC00_S_FICLST30SCR-RITEM, sy-vline,
WA_FC00_S_FICLST30SCR-SITYP, sy-vline,
WA_FC00_S_FICLST30SCR-SUBIT, sy-vline,
WA_FC00_S_FICLST30SCR-RBUPTR, sy-vline,
WA_FC00_S_FICLST30SCR-CGLVL, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FC00_S_FICLST30SCR you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FC00_S_FICLST30SCR TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FC00_S_FICLST30SCR INTO WA_FC00_S_FICLST30SCR. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field RLDNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FC00_S_FICLST30SCR-RLDNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC00_S_FICLST30SCR-RLDNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit AFIMC, internal->external for field RCONGR CALL FUNCTION 'CONVERSION_EXIT_AFIMC_OUTPUT' EXPORTING input = WA_FC00_S_FICLST30SCR-RCONGR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC00_S_FICLST30SCR-RCONGR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit AFIMC, internal->external for field RBUNIT CALL FUNCTION 'CONVERSION_EXIT_AFIMC_OUTPUT' EXPORTING input = WA_FC00_S_FICLST30SCR-RBUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC00_S_FICLST30SCR-RBUNIT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit BFIMC, internal->external for field RITEM CALL FUNCTION 'CONVERSION_EXIT_BFIMC_OUTPUT' EXPORTING input = WA_FC00_S_FICLST30SCR-RITEM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC00_S_FICLST30SCR-RITEM.
WRITE:/ 'New Value:', ld_input.
*Conversion exit AFIMC, internal->external for field RBUPTR CALL FUNCTION 'CONVERSION_EXIT_AFIMC_OUTPUT' EXPORTING input = WA_FC00_S_FICLST30SCR-RBUPTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC00_S_FICLST30SCR-RBUPTR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit AFIMC, internal->external for field CGLVL CALL FUNCTION 'CONVERSION_EXIT_AFIMC_OUTPUT' EXPORTING input = WA_FC00_S_FICLST30SCR-CGLVL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC00_S_FICLST30SCR-CGLVL.
WRITE:/ 'New Value:', ld_input.
*Conversion exit AFIMC, internal->external for field COICU CALL FUNCTION 'CONVERSION_EXIT_AFIMC_OUTPUT' EXPORTING input = WA_FC00_S_FICLST30SCR-COICU IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC00_S_FICLST30SCR-COICU.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field RVERS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FC00_S_FICLST30SCR-RVERS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC00_S_FICLST30SCR-RVERS.
WRITE:/ 'New Value:', ld_input.
*Conversion exit GJAHR, internal->external for field RYEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_FC00_S_FICLST30SCR-RYEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC00_S_FICLST30SCR-RYEAR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field RUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_FC00_S_FICLST30SCR-RUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC00_S_FICLST30SCR-RUNIT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field DOCNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FC00_S_FICLST30SCR-DOCNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC00_S_FICLST30SCR-DOCNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit GJAHR, internal->external for field YRACQ CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_FC00_S_FICLST30SCR-YRACQ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC00_S_FICLST30SCR-YRACQ.
WRITE:/ 'New Value:', ld_input.
*Conversion exit BFIMC, internal->external for field TOTALIT CALL FUNCTION 'CONVERSION_EXIT_BFIMC_OUTPUT' EXPORTING input = WA_FC00_S_FICLST30SCR-TOTALIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC00_S_FICLST30SCR-TOTALIT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FC00_S_FICLST30SCR_STR,
MANDT TYPE STRING,
RDIMEN TYPE STRING,
RLDNR TYPE STRING,
RCONGR TYPE STRING,
RBUNIT TYPE STRING,
RITCLG TYPE STRING,
RITEM TYPE STRING,
SITYP TYPE STRING,
SUBIT TYPE STRING,
RBUPTR TYPE STRING,
CGLVL TYPE STRING,
COICU TYPE STRING,
RVERS TYPE STRING,
RYEAR TYPE STRING,
POPER TYPE STRING,
RTCUR TYPE STRING,
RUNIT TYPE STRING,
PLEVL TYPE STRING,
BLEVL TYPE STRING,
RPFLG TYPE STRING,
RTFLG TYPE STRING,
DOCTY TYPE STRING,
DOCNR TYPE STRING,
YRACQ TYPE STRING,
PRACQ TYPE STRING,
FLG_CURPER TYPE STRING,
FLG_CURYEAR TYPE STRING,
TOTALIT TYPE STRING,
LCURR TYPE STRING,
GCURR TYPE STRING,END OF T_EKKO_STR. DATA: WA_FC00_S_FICLST30SCR_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FC00_S_FICLST30SCR_STR-MANDT sy-vline
WA_FC00_S_FICLST30SCR_STR-RDIMEN sy-vline
WA_FC00_S_FICLST30SCR_STR-RLDNR sy-vline
WA_FC00_S_FICLST30SCR_STR-RCONGR sy-vline
WA_FC00_S_FICLST30SCR_STR-RBUNIT sy-vline
WA_FC00_S_FICLST30SCR_STR-RITCLG sy-vline
WA_FC00_S_FICLST30SCR_STR-RITEM sy-vline
WA_FC00_S_FICLST30SCR_STR-SITYP sy-vline
WA_FC00_S_FICLST30SCR_STR-SUBIT sy-vline
WA_FC00_S_FICLST30SCR_STR-RBUPTR sy-vline
WA_FC00_S_FICLST30SCR_STR-CGLVL sy-vline
WA_FC00_S_FICLST30SCR_STR-COICU sy-vline
WA_FC00_S_FICLST30SCR_STR-RVERS sy-vline
WA_FC00_S_FICLST30SCR_STR-RYEAR sy-vline
WA_FC00_S_FICLST30SCR_STR-POPER sy-vline
WA_FC00_S_FICLST30SCR_STR-RTCUR sy-vline
WA_FC00_S_FICLST30SCR_STR-RUNIT sy-vline
WA_FC00_S_FICLST30SCR_STR-PLEVL sy-vline
WA_FC00_S_FICLST30SCR_STR-BLEVL sy-vline
WA_FC00_S_FICLST30SCR_STR-RPFLG sy-vline
WA_FC00_S_FICLST30SCR_STR-RTFLG sy-vline
WA_FC00_S_FICLST30SCR_STR-DOCTY sy-vline
WA_FC00_S_FICLST30SCR_STR-DOCNR sy-vline
WA_FC00_S_FICLST30SCR_STR-YRACQ sy-vline
WA_FC00_S_FICLST30SCR_STR-PRACQ sy-vline
WA_FC00_S_FICLST30SCR_STR-FLG_CURPER sy-vline
WA_FC00_S_FICLST30SCR_STR-FLG_CURYEAR sy-vline
WA_FC00_S_FICLST30SCR_STR-TOTALIT sy-vline
WA_FC00_S_FICLST30SCR_STR-LCURR sy-vline
WA_FC00_S_FICLST30SCR_STR-GCURR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.