ABAP Select data from SAP table FC03_S_VAL_BINTREE into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FC03_S_VAL_BINTREE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FC03_S_VAL_BINTREE. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FC03_S_VAL_BINTREE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FC03_S_VAL_BINTREE TYPE STANDARD TABLE OF FC03_S_VAL_BINTREE,
      WA_FC03_S_VAL_BINTREE TYPE FC03_S_VAL_BINTREE,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FC03_S_VAL_BINTREE> TYPE FC03_S_VAL_BINTREE.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FC03_S_VAL_BINTREE.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FC03_S_VAL_BINTREE
  INTO TABLE IT_FC03_S_VAL_BINTREE.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FC03_S_VAL_BINTREE
*  INTO TABLE @DATA(IT_FC03_S_VAL_BINTREE2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FC03_S_VAL_BINTREE INDEX 1 INTO DATA(WA_FC03_S_VAL_BINTREE2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FC03_S_VAL_BINTREE ASSIGNING <FC03_S_VAL_BINTREE>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FC03_S_VAL_BINTREE>-NODE_PTR = 1.
<FC03_S_VAL_BINTREE>-LHS_PTR = 1.
<FC03_S_VAL_BINTREE>-RHS_PTR = 1.
<FC03_S_VAL_BINTREE>-OPERATOR = 1.
<FC03_S_VAL_BINTREE>-KFIG = 1.
ENDLOOP.

LOOP AT IT_FC03_S_VAL_BINTREE INTO WA_FC03_S_VAL_BINTREE.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FC03_S_VAL_BINTREE-FLG_YTD, sy-vline,
WA_FC03_S_VAL_BINTREE-RULENAME, sy-vline,
WA_FC03_S_VAL_BINTREE-CUKY, sy-vline,
WA_FC03_S_VAL_BINTREE-UNIT, sy-vline,
WA_FC03_S_VAL_BINTREE-VALUE_HSL, sy-vline,
WA_FC03_S_VAL_BINTREE-VALUE_KSL, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FC03_S_VAL_BINTREE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FC03_S_VAL_BINTREE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FC03_S_VAL_BINTREE INTO WA_FC03_S_VAL_BINTREE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field UNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_FC03_S_VAL_BINTREE-UNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC03_S_VAL_BINTREE-UNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field VALUE_HSL CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_FC03_S_VAL_BINTREE-VALUE_HSL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC03_S_VAL_BINTREE-VALUE_HSL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field VALUE_KSL CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_FC03_S_VAL_BINTREE-VALUE_KSL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC03_S_VAL_BINTREE-VALUE_KSL.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FC03_S_VAL_BINTREE_STR,
NODE_PTR TYPE STRING,
LHS_PTR TYPE STRING,
RHS_PTR TYPE STRING,
OPERATOR TYPE STRING,
KFIG TYPE STRING,
FLG_YTD TYPE STRING,
RULENAME TYPE STRING,
CUKY TYPE STRING,
UNIT TYPE STRING,
VALUE_HSL TYPE STRING,
VALUE_KSL TYPE STRING,
VALUE_DEF TYPE STRING,
VALUE_MSL TYPE STRING,
GROUP_BY_USED TYPE STRING,
GROUP_BY TYPE STRING,END OF T_EKKO_STR. DATA: WA_FC03_S_VAL_BINTREE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FC03_S_VAL_BINTREE_STR-NODE_PTR sy-vline
WA_FC03_S_VAL_BINTREE_STR-LHS_PTR sy-vline
WA_FC03_S_VAL_BINTREE_STR-RHS_PTR sy-vline
WA_FC03_S_VAL_BINTREE_STR-OPERATOR sy-vline
WA_FC03_S_VAL_BINTREE_STR-KFIG sy-vline
WA_FC03_S_VAL_BINTREE_STR-FLG_YTD sy-vline
WA_FC03_S_VAL_BINTREE_STR-RULENAME sy-vline
WA_FC03_S_VAL_BINTREE_STR-CUKY sy-vline
WA_FC03_S_VAL_BINTREE_STR-UNIT sy-vline
WA_FC03_S_VAL_BINTREE_STR-VALUE_HSL sy-vline
WA_FC03_S_VAL_BINTREE_STR-VALUE_KSL sy-vline
WA_FC03_S_VAL_BINTREE_STR-VALUE_DEF sy-vline
WA_FC03_S_VAL_BINTREE_STR-VALUE_MSL sy-vline
WA_FC03_S_VAL_BINTREE_STR-GROUP_BY_USED sy-vline
WA_FC03_S_VAL_BINTREE_STR-GROUP_BY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.