ABAP Select data from SAP table FC05_S_IUE into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FC05_S_IUE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FC05_S_IUE. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FC05_S_IUE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FC05_S_IUE TYPE STANDARD TABLE OF FC05_S_IUE,
      WA_FC05_S_IUE TYPE FC05_S_IUE,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FC05_S_IUE> TYPE FC05_S_IUE.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FC05_S_IUE.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FC05_S_IUE
  INTO TABLE IT_FC05_S_IUE.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FC05_S_IUE
*  INTO TABLE @DATA(IT_FC05_S_IUE2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FC05_S_IUE INDEX 1 INTO DATA(WA_FC05_S_IUE2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FC05_S_IUE ASSIGNING <FC05_S_IUE>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FC05_S_IUE>-RITEM = 1.
<FC05_S_IUE>-SITYP = 1.
<FC05_S_IUE>-SUBIT = 1.
<FC05_S_IUE>-RBUPTR = 1.
<FC05_S_IUE>-YRACQ = 1.
ENDLOOP.

LOOP AT IT_FC05_S_IUE INTO WA_FC05_S_IUE.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FC05_S_IUE-PRACQ, sy-vline,
WA_FC05_S_IUE-RTCUR, sy-vline,
WA_FC05_S_IUE-RUNIT, sy-vline,
WA_FC05_S_IUE-CNTRY, sy-vline,
WA_FC05_S_IUE-RCOMP, sy-vline,
WA_FC05_S_IUE-GSBER_KONS, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FC05_S_IUE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FC05_S_IUE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FC05_S_IUE INTO WA_FC05_S_IUE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit BFIMC, internal->external for field RITEM CALL FUNCTION 'CONVERSION_EXIT_BFIMC_OUTPUT' EXPORTING input = WA_FC05_S_IUE-RITEM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC05_S_IUE-RITEM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AFIMC, internal->external for field RBUPTR CALL FUNCTION 'CONVERSION_EXIT_AFIMC_OUTPUT' EXPORTING input = WA_FC05_S_IUE-RBUPTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC05_S_IUE-RBUPTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field YRACQ CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_FC05_S_IUE-YRACQ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC05_S_IUE-YRACQ.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field RUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_FC05_S_IUE-RUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC05_S_IUE-RUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RCOMP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FC05_S_IUE-RCOMP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC05_S_IUE-RCOMP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field PRCTR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FC05_S_IUE-PRCTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC05_S_IUE-PRCTR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FC05_S_IUE_STR,
RITEM TYPE STRING,
SITYP TYPE STRING,
SUBIT TYPE STRING,
RBUPTR TYPE STRING,
YRACQ TYPE STRING,
PRACQ TYPE STRING,
RTCUR TYPE STRING,
RUNIT TYPE STRING,
CNTRY TYPE STRING,
RCOMP TYPE STRING,
GSBER_KONS TYPE STRING,
KOKRS TYPE STRING,
PRCTR TYPE STRING,END OF T_EKKO_STR. DATA: WA_FC05_S_IUE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FC05_S_IUE_STR-RITEM sy-vline
WA_FC05_S_IUE_STR-SITYP sy-vline
WA_FC05_S_IUE_STR-SUBIT sy-vline
WA_FC05_S_IUE_STR-RBUPTR sy-vline
WA_FC05_S_IUE_STR-YRACQ sy-vline
WA_FC05_S_IUE_STR-PRACQ sy-vline
WA_FC05_S_IUE_STR-RTCUR sy-vline
WA_FC05_S_IUE_STR-RUNIT sy-vline
WA_FC05_S_IUE_STR-CNTRY sy-vline
WA_FC05_S_IUE_STR-RCOMP sy-vline
WA_FC05_S_IUE_STR-GSBER_KONS sy-vline
WA_FC05_S_IUE_STR-KOKRS sy-vline
WA_FC05_S_IUE_STR-PRCTR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.