ABAP Select data from SAP table FC05I90LST into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP FC05I90LST table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FC05I90LST. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the FC05I90LST table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_FC05I90LST TYPE STANDARD TABLE OF FC05I90LST, WA_FC05I90LST TYPE FC05I90LST, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <FC05I90LST> TYPE FC05I90LST. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_FC05I90LST. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM FC05I90LST INTO TABLE IT_FC05I90LST. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM FC05I90LST * INTO TABLE @DATA(IT_FC05I90LST2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_FC05I90LST INDEX 1 INTO DATA(WA_FC05I90LST2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_FC05I90LST ASSIGNING <FC05I90LST>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<FC05I90LST>-SUMIND = 1.
<FC05I90LST>-DIMEN = 1.
<FC05I90LST>-ITCLG = 1.
<FC05I90LST>-CMETH = 1.
<FC05I90LST>-TXT = 1.
ENDLOOP. LOOP AT IT_FC05I90LST INTO WA_FC05I90LST. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_FC05I90LST-CRIT, sy-vline,
WA_FC05I90LST-SEQNO, sy-vline,
WA_FC05I90LST-LISTNO, sy-vline,
WA_FC05I90LST-SCRTXT, sy-vline,
WA_FC05I90LST-VAL_TXT, sy-vline,
WA_FC05I90LST-VALUE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FC05I90LST you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FC05I90LST TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FC05I90LST INTO WA_FC05I90LST. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit AC172, internal->external for field LIMIT CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_FC05I90LST-LIMIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC05I90LST-LIMIT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit BFIMC, internal->external for field PFITEM CALL FUNCTION 'CONVERSION_EXIT_BFIMC_OUTPUT' EXPORTING input = WA_FC05I90LST-PFITEM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC05I90LST-PFITEM.
WRITE:/ 'New Value:', ld_input.
*Conversion exit BFIMC, internal->external for field PTITEM CALL FUNCTION 'CONVERSION_EXIT_BFIMC_OUTPUT' EXPORTING input = WA_FC05I90LST-PTITEM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC05I90LST-PTITEM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FC05I90LST_STR,
SUMIND TYPE STRING,
DIMEN TYPE STRING,
ITCLG TYPE STRING,
CMETH TYPE STRING,
TXT TYPE STRING,
CRIT TYPE STRING,
SEQNO TYPE STRING,
LISTNO TYPE STRING,
SCRTXT TYPE STRING,
VAL_TXT TYPE STRING,
VALUE TYPE STRING,
DEFLT TYPE STRING,
CRIT1 TYPE STRING,
VERNO TYPE STRING,
SETID TYPE STRING,
SETTITLE TYPE STRING,
ITGIND TYPE STRING,
CRIT2 TYPE STRING,
SETNO TYPE STRING,
FROM_VAL TYPE STRING,
TO_VAL TYPE STRING,
OSIIND TYPE STRING,
OSPIND TYPE STRING,
TCSIND TYPE STRING,
DIFIND TYPE STRING,
CUTYP TYPE STRING,
LIMIND TYPE STRING,
CURR TYPE STRING,
LIMIT TYPE STRING,
PFITEM TYPE STRING,
PFSITYP TYPE STRING,
PFSITEM TYPE STRING,
PTITEM TYPE STRING,
PTSITYP TYPE STRING,
PTSITEM TYPE STRING,END OF T_EKKO_STR. DATA: WA_FC05I90LST_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FC05I90LST_STR-SUMIND sy-vline
WA_FC05I90LST_STR-DIMEN sy-vline
WA_FC05I90LST_STR-ITCLG sy-vline
WA_FC05I90LST_STR-CMETH sy-vline
WA_FC05I90LST_STR-TXT sy-vline
WA_FC05I90LST_STR-CRIT sy-vline
WA_FC05I90LST_STR-SEQNO sy-vline
WA_FC05I90LST_STR-LISTNO sy-vline
WA_FC05I90LST_STR-SCRTXT sy-vline
WA_FC05I90LST_STR-VAL_TXT sy-vline
WA_FC05I90LST_STR-VALUE sy-vline
WA_FC05I90LST_STR-DEFLT sy-vline
WA_FC05I90LST_STR-CRIT1 sy-vline
WA_FC05I90LST_STR-VERNO sy-vline
WA_FC05I90LST_STR-SETID sy-vline
WA_FC05I90LST_STR-SETTITLE sy-vline
WA_FC05I90LST_STR-ITGIND sy-vline
WA_FC05I90LST_STR-CRIT2 sy-vline
WA_FC05I90LST_STR-SETNO sy-vline
WA_FC05I90LST_STR-FROM_VAL sy-vline
WA_FC05I90LST_STR-TO_VAL sy-vline
WA_FC05I90LST_STR-OSIIND sy-vline
WA_FC05I90LST_STR-OSPIND sy-vline
WA_FC05I90LST_STR-TCSIND sy-vline
WA_FC05I90LST_STR-DIFIND sy-vline
WA_FC05I90LST_STR-CUTYP sy-vline
WA_FC05I90LST_STR-LIMIND sy-vline
WA_FC05I90LST_STR-CURR sy-vline
WA_FC05I90LST_STR-LIMIT sy-vline
WA_FC05I90LST_STR-PFITEM sy-vline
WA_FC05I90LST_STR-PFSITYP sy-vline
WA_FC05I90LST_STR-PFSITEM sy-vline
WA_FC05I90LST_STR-PTITEM sy-vline
WA_FC05I90LST_STR-PTSITYP sy-vline
WA_FC05I90LST_STR-PTSITEM sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.