ABAP Select data from SAP table FC05PI85LST into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FC05PI85LST table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FC05PI85LST. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FC05PI85LST table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FC05PI85LST TYPE STANDARD TABLE OF FC05PI85LST,
      WA_FC05PI85LST TYPE FC05PI85LST,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FC05PI85LST> TYPE FC05PI85LST.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FC05PI85LST.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FC05PI85LST
  INTO TABLE IT_FC05PI85LST.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FC05PI85LST
*  INTO TABLE @DATA(IT_FC05PI85LST2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FC05PI85LST INDEX 1 INTO DATA(WA_FC05PI85LST2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FC05PI85LST ASSIGNING <FC05PI85LST>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FC05PI85LST>-BUNIT = 1.
<FC05PI85LST>-BUTXT = 1.
<FC05PI85LST>-BUPTR = 1.
<FC05PI85LST>-PTTXT = 1.
<FC05PI85LST>-RYEAR = 1.
ENDLOOP.

LOOP AT IT_FC05PI85LST INTO WA_FC05PI85LST.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FC05PI85LST-PERID, sy-vline,
WA_FC05PI85LST-PRGRP, sy-vline,
WA_FC05PI85LST-PRGRPTXT, sy-vline,
WA_FC05PI85LST-ITEM, sy-vline,
WA_FC05PI85LST-ITEMTXT, sy-vline,
WA_FC05PI85LST-BKVAL, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FC05PI85LST you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FC05PI85LST TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FC05PI85LST INTO WA_FC05PI85LST. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit AFIMC, internal->external for field BUNIT CALL FUNCTION 'CONVERSION_EXIT_AFIMC_OUTPUT' EXPORTING input = WA_FC05PI85LST-BUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC05PI85LST-BUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AFIMC, internal->external for field BUPTR CALL FUNCTION 'CONVERSION_EXIT_AFIMC_OUTPUT' EXPORTING input = WA_FC05PI85LST-BUPTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC05PI85LST-BUPTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field RYEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_FC05PI85LST-RYEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC05PI85LST-RYEAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit BFIMC, internal->external for field ITEM CALL FUNCTION 'CONVERSION_EXIT_BFIMC_OUTPUT' EXPORTING input = WA_FC05PI85LST-ITEM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC05PI85LST-ITEM.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AU172, internal->external for field BKVAL CALL FUNCTION 'CONVERSION_EXIT_AU172_OUTPUT' EXPORTING input = WA_FC05PI85LST-BKVAL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC05PI85LST-BKVAL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field VLCNL CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_FC05PI85LST-VLCNL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC05PI85LST-VLCNL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field VLCLF CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_FC05PI85LST-VLCLF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC05PI85LST-VLCLF.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AU172, internal->external for field ADDCO CALL FUNCTION 'CONVERSION_EXIT_AU172_OUTPUT' EXPORTING input = WA_FC05PI85LST-ADDCO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC05PI85LST-ADDCO.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field MSEHI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_FC05PI85LST-MSEHI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FC05PI85LST-MSEHI.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FC05PI85LST_STR,
BUNIT TYPE STRING,
BUTXT TYPE STRING,
BUPTR TYPE STRING,
PTTXT TYPE STRING,
RYEAR TYPE STRING,
PERID TYPE STRING,
PRGRP TYPE STRING,
PRGRPTXT TYPE STRING,
ITEM TYPE STRING,
ITEMTXT TYPE STRING,
BKVAL TYPE STRING,
VLCNL TYPE STRING,
VLCLF TYPE STRING,
ADDCO TYPE STRING,
CURR TYPE STRING,
ACPCT TYPE STRING,
QUANT TYPE STRING,
MSEHI TYPE STRING,END OF T_EKKO_STR. DATA: WA_FC05PI85LST_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FC05PI85LST_STR-BUNIT sy-vline
WA_FC05PI85LST_STR-BUTXT sy-vline
WA_FC05PI85LST_STR-BUPTR sy-vline
WA_FC05PI85LST_STR-PTTXT sy-vline
WA_FC05PI85LST_STR-RYEAR sy-vline
WA_FC05PI85LST_STR-PERID sy-vline
WA_FC05PI85LST_STR-PRGRP sy-vline
WA_FC05PI85LST_STR-PRGRPTXT sy-vline
WA_FC05PI85LST_STR-ITEM sy-vline
WA_FC05PI85LST_STR-ITEMTXT sy-vline
WA_FC05PI85LST_STR-BKVAL sy-vline
WA_FC05PI85LST_STR-VLCNL sy-vline
WA_FC05PI85LST_STR-VLCLF sy-vline
WA_FC05PI85LST_STR-ADDCO sy-vline
WA_FC05PI85LST_STR-CURR sy-vline
WA_FC05PI85LST_STR-ACPCT sy-vline
WA_FC05PI85LST_STR-QUANT sy-vline
WA_FC05PI85LST_STR-MSEHI sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.