ABAP Select data from SAP table FCLM_BRM_COND into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FCLM_BRM_COND table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FCLM_BRM_COND. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FCLM_BRM_COND table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FCLM_BRM_COND TYPE STANDARD TABLE OF FCLM_BRM_COND,
      WA_FCLM_BRM_COND TYPE FCLM_BRM_COND,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FCLM_BRM_COND> TYPE FCLM_BRM_COND.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FCLM_BRM_COND.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FCLM_BRM_COND
  INTO TABLE IT_FCLM_BRM_COND.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FCLM_BRM_COND
*  INTO TABLE @DATA(IT_FCLM_BRM_COND2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FCLM_BRM_COND INDEX 1 INTO DATA(WA_FCLM_BRM_COND2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FCLM_BRM_COND ASSIGNING <FCLM_BRM_COND>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FCLM_BRM_COND>-MANDT = 1.
<FCLM_BRM_COND>-CONDAREA = 1.
<FCLM_BRM_COND>-COND = 1.
<FCLM_BRM_COND>-VALIDFROM = 1.
<FCLM_BRM_COND>-CHARGEMETHOD = 1.
ENDLOOP.

LOOP AT IT_FCLM_BRM_COND INTO WA_FCLM_BRM_COND.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FCLM_BRM_COND-CONDCATG, sy-vline,
WA_FCLM_BRM_COND-CONDDIF, sy-vline,
WA_FCLM_BRM_COND-CONDDIF_V1, sy-vline,
WA_FCLM_BRM_COND-CONDDIF_2, sy-vline,
WA_FCLM_BRM_COND-CONDDIF_V2, sy-vline,
WA_FCLM_BRM_COND-CURR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FCLM_BRM_COND you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FCLM_BRM_COND TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FCLM_BRM_COND INTO WA_FCLM_BRM_COND. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FCLM_BRM_COND_STR,
MANDT TYPE STRING,
CONDAREA TYPE STRING,
COND TYPE STRING,
VALIDFROM TYPE STRING,
CHARGEMETHOD TYPE STRING,
CONDCATG TYPE STRING,
CONDDIF TYPE STRING,
CONDDIF_V1 TYPE STRING,
CONDDIF_2 TYPE STRING,
CONDDIF_V2 TYPE STRING,
CURR TYPE STRING,
INTMET TYPE STRING,
STGMETH TYPE STRING,
STGBASIS TYPE STRING,
CALCTYP TYPE STRING,
FLGFROMTO TYPE STRING,
FLGADDDEBI TYPE STRING,
CONDTIME TYPE STRING,
CONDTIME_U TYPE STRING,
TIMEPROPCALC TYPE STRING,
FREECOUNT TYPE STRING,
EXEMPTLIM TYPE STRING,
FLGLOCKED TYPE STRING,
SORTF TYPE STRING,
USEDTILL TYPE STRING,
XSURCHARGE TYPE STRING,
SROUND TYPE STRING,
PRUNIT TYPE STRING,
ADINTMET TYPE STRING,
XZEROLIM TYPE STRING,
CRUSER TYPE STRING,
CRDATE TYPE STRING,
CRTIME TYPE STRING,
CHGUSER TYPE STRING,
CHGDATE TYPE STRING,
CHGTIME TYPE STRING,
RELUSER TYPE STRING,
RELDATE TYPE STRING,
RELTIME TYPE STRING,
X_DUEDATE TYPE STRING,
X_VD_DUEDATE TYPE STRING,END OF T_EKKO_STR. DATA: WA_FCLM_BRM_COND_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FCLM_BRM_COND_STR-MANDT sy-vline
WA_FCLM_BRM_COND_STR-CONDAREA sy-vline
WA_FCLM_BRM_COND_STR-COND sy-vline
WA_FCLM_BRM_COND_STR-VALIDFROM sy-vline
WA_FCLM_BRM_COND_STR-CHARGEMETHOD sy-vline
WA_FCLM_BRM_COND_STR-CONDCATG sy-vline
WA_FCLM_BRM_COND_STR-CONDDIF sy-vline
WA_FCLM_BRM_COND_STR-CONDDIF_V1 sy-vline
WA_FCLM_BRM_COND_STR-CONDDIF_2 sy-vline
WA_FCLM_BRM_COND_STR-CONDDIF_V2 sy-vline
WA_FCLM_BRM_COND_STR-CURR sy-vline
WA_FCLM_BRM_COND_STR-INTMET sy-vline
WA_FCLM_BRM_COND_STR-STGMETH sy-vline
WA_FCLM_BRM_COND_STR-STGBASIS sy-vline
WA_FCLM_BRM_COND_STR-CALCTYP sy-vline
WA_FCLM_BRM_COND_STR-FLGFROMTO sy-vline
WA_FCLM_BRM_COND_STR-FLGADDDEBI sy-vline
WA_FCLM_BRM_COND_STR-CONDTIME sy-vline
WA_FCLM_BRM_COND_STR-CONDTIME_U sy-vline
WA_FCLM_BRM_COND_STR-TIMEPROPCALC sy-vline
WA_FCLM_BRM_COND_STR-FREECOUNT sy-vline
WA_FCLM_BRM_COND_STR-EXEMPTLIM sy-vline
WA_FCLM_BRM_COND_STR-FLGLOCKED sy-vline
WA_FCLM_BRM_COND_STR-SORTF sy-vline
WA_FCLM_BRM_COND_STR-USEDTILL sy-vline
WA_FCLM_BRM_COND_STR-XSURCHARGE sy-vline
WA_FCLM_BRM_COND_STR-SROUND sy-vline
WA_FCLM_BRM_COND_STR-PRUNIT sy-vline
WA_FCLM_BRM_COND_STR-ADINTMET sy-vline
WA_FCLM_BRM_COND_STR-XZEROLIM sy-vline
WA_FCLM_BRM_COND_STR-CRUSER sy-vline
WA_FCLM_BRM_COND_STR-CRDATE sy-vline
WA_FCLM_BRM_COND_STR-CRTIME sy-vline
WA_FCLM_BRM_COND_STR-CHGUSER sy-vline
WA_FCLM_BRM_COND_STR-CHGDATE sy-vline
WA_FCLM_BRM_COND_STR-CHGTIME sy-vline
WA_FCLM_BRM_COND_STR-RELUSER sy-vline
WA_FCLM_BRM_COND_STR-RELDATE sy-vline
WA_FCLM_BRM_COND_STR-RELTIME sy-vline
WA_FCLM_BRM_COND_STR-X_DUEDATE sy-vline
WA_FCLM_BRM_COND_STR-X_VD_DUEDATE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.