ABAP Select data from SAP table FCOV_CHECK1A into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP FCOV_CHECK1A table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FCOV_CHECK1A. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the FCOV_CHECK1A table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_FCOV_CHECK1A TYPE STANDARD TABLE OF FCOV_CHECK1A, WA_FCOV_CHECK1A TYPE FCOV_CHECK1A, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <FCOV_CHECK1A> TYPE FCOV_CHECK1A. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_FCOV_CHECK1A. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM FCOV_CHECK1A INTO TABLE IT_FCOV_CHECK1A. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM FCOV_CHECK1A * INTO TABLE @DATA(IT_FCOV_CHECK1A2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_FCOV_CHECK1A INDEX 1 INTO DATA(WA_FCOV_CHECK1A2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_FCOV_CHECK1A ASSIGNING <FCOV_CHECK1A>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<FCOV_CHECK1A>-MANDT = 1.
<FCOV_CHECK1A>-LEDNR = 1.
<FCOV_CHECK1A>-OBJNR = 1.
<FCOV_CHECK1A>-GJAHR = 1.
<FCOV_CHECK1A>-WRTTP = 1.
ENDLOOP. LOOP AT IT_FCOV_CHECK1A INTO WA_FCOV_CHECK1A. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_FCOV_CHECK1A-VERSN, sy-vline,
WA_FCOV_CHECK1A-KSTAR, sy-vline,
WA_FCOV_CHECK1A-HRKFT, sy-vline,
WA_FCOV_CHECK1A-VRGNG, sy-vline,
WA_FCOV_CHECK1A-VBUND, sy-vline,
WA_FCOV_CHECK1A-PARGB, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FCOV_CHECK1A you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FCOV_CHECK1A TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FCOV_CHECK1A INTO WA_FCOV_CHECK1A. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field LEDNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FCOV_CHECK1A-LEDNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FCOV_CHECK1A-LEDNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit GJAHR, internal->external for field GJAHR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_FCOV_CHECK1A-GJAHR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FCOV_CHECK1A-GJAHR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field WRTTP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FCOV_CHECK1A-WRTTP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FCOV_CHECK1A-WRTTP.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field VERSN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FCOV_CHECK1A-VERSN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FCOV_CHECK1A-VERSN.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field KSTAR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FCOV_CHECK1A-KSTAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FCOV_CHECK1A-KSTAR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field VBUND CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FCOV_CHECK1A-VBUND IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FCOV_CHECK1A-VBUND.
WRITE:/ 'New Value:', ld_input.
*Conversion exit BEKNZ, internal->external for field BEKNZ CALL FUNCTION 'CONVERSION_EXIT_BEKNZ_OUTPUT' EXPORTING input = WA_FCOV_CHECK1A-BEKNZ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FCOV_CHECK1A-BEKNZ.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FCOV_CHECK1A_STR,
MANDT TYPE STRING,
LEDNR TYPE STRING,
OBJNR TYPE STRING,
GJAHR TYPE STRING,
WRTTP TYPE STRING,
VERSN TYPE STRING,
KSTAR TYPE STRING,
HRKFT TYPE STRING,
VRGNG TYPE STRING,
VBUND TYPE STRING,
PARGB TYPE STRING,
BEKNZ TYPE STRING,
TWAER TYPE STRING,
PERBL TYPE STRING,
BUKRS TYPE STRING,
SYSUBRC TYPE STRING,END OF T_EKKO_STR. DATA: WA_FCOV_CHECK1A_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FCOV_CHECK1A_STR-MANDT sy-vline
WA_FCOV_CHECK1A_STR-LEDNR sy-vline
WA_FCOV_CHECK1A_STR-OBJNR sy-vline
WA_FCOV_CHECK1A_STR-GJAHR sy-vline
WA_FCOV_CHECK1A_STR-WRTTP sy-vline
WA_FCOV_CHECK1A_STR-VERSN sy-vline
WA_FCOV_CHECK1A_STR-KSTAR sy-vline
WA_FCOV_CHECK1A_STR-HRKFT sy-vline
WA_FCOV_CHECK1A_STR-VRGNG sy-vline
WA_FCOV_CHECK1A_STR-VBUND sy-vline
WA_FCOV_CHECK1A_STR-PARGB sy-vline
WA_FCOV_CHECK1A_STR-BEKNZ sy-vline
WA_FCOV_CHECK1A_STR-TWAER sy-vline
WA_FCOV_CHECK1A_STR-PERBL sy-vline
WA_FCOV_CHECK1A_STR-BUKRS sy-vline
WA_FCOV_CHECK1A_STR-SYSUBRC sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.