ABAP Select data from SAP table FDM_UI_ATTRIBUTES into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP FDM_UI_ATTRIBUTES table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FDM_UI_ATTRIBUTES. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the FDM_UI_ATTRIBUTES table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_FDM_UI_ATTRIBUTES TYPE STANDARD TABLE OF FDM_UI_ATTRIBUTES, WA_FDM_UI_ATTRIBUTES TYPE FDM_UI_ATTRIBUTES, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <FDM_UI_ATTRIBUTES> TYPE FDM_UI_ATTRIBUTES. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_FDM_UI_ATTRIBUTES. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM FDM_UI_ATTRIBUTES INTO TABLE IT_FDM_UI_ATTRIBUTES. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM FDM_UI_ATTRIBUTES * INTO TABLE @DATA(IT_FDM_UI_ATTRIBUTES2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_FDM_UI_ATTRIBUTES INDEX 1 INTO DATA(WA_FDM_UI_ATTRIBUTES2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_FDM_UI_ATTRIBUTES ASSIGNING <FDM_UI_ATTRIBUTES>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<FDM_UI_ATTRIBUTES>-EXT_KEY = 1.
<FDM_UI_ATTRIBUTES>-EXT_REF = 1.
<FDM_UI_ATTRIBUTES>-CASE_TYPE = 1.
<FDM_UI_ATTRIBUTES>-PRIORITY = 1.
<FDM_UI_ATTRIBUTES>-CATEGORY = 1.
ENDLOOP. LOOP AT IT_FDM_UI_ATTRIBUTES INTO WA_FDM_UI_ATTRIBUTES. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_FDM_UI_ATTRIBUTES-CASE_TITLE, sy-vline,
WA_FDM_UI_ATTRIBUTES-REASON_CODE, sy-vline,
WA_FDM_UI_ATTRIBUTES-PROCESSOR, sy-vline,
WA_FDM_UI_ATTRIBUTES-RESPONSIBLE, sy-vline,
WA_FDM_UI_ATTRIBUTES-FIN_COORDINATOR, sy-vline,
WA_FDM_UI_ATTRIBUTES-FIN_DUE_DATE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FDM_UI_ATTRIBUTES you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FDM_UI_ATTRIBUTES TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FDM_UI_ATTRIBUTES INTO WA_FDM_UI_ATTRIBUTES. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field EXT_KEY CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FDM_UI_ATTRIBUTES-EXT_KEY IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FDM_UI_ATTRIBUTES-EXT_KEY.
WRITE:/ 'New Value:', ld_input.
*Conversion exit TSTPS, internal->external for field CREATE_TIME CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_FDM_UI_ATTRIBUTES-CREATE_TIME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FDM_UI_ATTRIBUTES-CREATE_TIME.
WRITE:/ 'New Value:', ld_input.
*Conversion exit TSTPS, internal->external for field CHANGE_TIME CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_FDM_UI_ATTRIBUTES-CHANGE_TIME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FDM_UI_ATTRIBUTES-CHANGE_TIME.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field FIN_KUNNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FDM_UI_ATTRIBUTES-FIN_KUNNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FDM_UI_ATTRIBUTES-FIN_KUNNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FDM_UI_ATTRIBUTES_STR,
EXT_KEY TYPE STRING,
EXT_REF TYPE STRING,
CASE_TYPE TYPE STRING,
PRIORITY TYPE STRING,
CATEGORY TYPE STRING,
CASE_TITLE TYPE STRING,
REASON_CODE TYPE STRING,
PROCESSOR TYPE STRING,
RESPONSIBLE TYPE STRING,
FIN_COORDINATOR TYPE STRING,
FIN_DUE_DATE TYPE STRING,
PLAN_END_DATE TYPE STRING,
FIN_DISPUTE_CURR TYPE STRING,
FIN_CUSTDISP_AMT TYPE STRING,
FIN_CUSTDISP_CUR TYPE STRING,
FIN_CONTACT_NAME_LABEL TYPE STRING,
FIN_CONTACT_NAME TYPE STRING,
FIN_CONTACT_MAIL TYPE STRING,
FIN_CONTACT_TEL TYPE STRING,
FIN_CONTACT_FAX TYPE STRING,
FIN_CONTACT_FAXC TYPE STRING,
FIN_CONTACT_KEY TYPE STRING,
FIN_PROMISED_BY TYPE STRING,
CREATE_TIME TYPE STRING,
CHANGE_TIME TYPE STRING,
STAT_ORDERNO TYPE STRING,
FIN_KUNNR TYPE STRING,END OF T_EKKO_STR. DATA: WA_FDM_UI_ATTRIBUTES_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FDM_UI_ATTRIBUTES_STR-EXT_KEY sy-vline
WA_FDM_UI_ATTRIBUTES_STR-EXT_REF sy-vline
WA_FDM_UI_ATTRIBUTES_STR-CASE_TYPE sy-vline
WA_FDM_UI_ATTRIBUTES_STR-PRIORITY sy-vline
WA_FDM_UI_ATTRIBUTES_STR-CATEGORY sy-vline
WA_FDM_UI_ATTRIBUTES_STR-CASE_TITLE sy-vline
WA_FDM_UI_ATTRIBUTES_STR-REASON_CODE sy-vline
WA_FDM_UI_ATTRIBUTES_STR-PROCESSOR sy-vline
WA_FDM_UI_ATTRIBUTES_STR-RESPONSIBLE sy-vline
WA_FDM_UI_ATTRIBUTES_STR-FIN_COORDINATOR sy-vline
WA_FDM_UI_ATTRIBUTES_STR-FIN_DUE_DATE sy-vline
WA_FDM_UI_ATTRIBUTES_STR-PLAN_END_DATE sy-vline
WA_FDM_UI_ATTRIBUTES_STR-FIN_DISPUTE_CURR sy-vline
WA_FDM_UI_ATTRIBUTES_STR-FIN_CUSTDISP_AMT sy-vline
WA_FDM_UI_ATTRIBUTES_STR-FIN_CUSTDISP_CUR sy-vline
WA_FDM_UI_ATTRIBUTES_STR-FIN_CONTACT_NAME_LABEL sy-vline
WA_FDM_UI_ATTRIBUTES_STR-FIN_CONTACT_NAME sy-vline
WA_FDM_UI_ATTRIBUTES_STR-FIN_CONTACT_MAIL sy-vline
WA_FDM_UI_ATTRIBUTES_STR-FIN_CONTACT_TEL sy-vline
WA_FDM_UI_ATTRIBUTES_STR-FIN_CONTACT_FAX sy-vline
WA_FDM_UI_ATTRIBUTES_STR-FIN_CONTACT_FAXC sy-vline
WA_FDM_UI_ATTRIBUTES_STR-FIN_CONTACT_KEY sy-vline
WA_FDM_UI_ATTRIBUTES_STR-FIN_PROMISED_BY sy-vline
WA_FDM_UI_ATTRIBUTES_STR-CREATE_TIME sy-vline
WA_FDM_UI_ATTRIBUTES_STR-CHANGE_TIME sy-vline
WA_FDM_UI_ATTRIBUTES_STR-STAT_ORDERNO sy-vline
WA_FDM_UI_ATTRIBUTES_STR-FIN_KUNNR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.