ABAP Select data from SAP table FDT_INC_APPL_0000_DATA into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP FDT_INC_APPL_0000_DATA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FDT_INC_APPL_0000_DATA. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the FDT_INC_APPL_0000_DATA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_FDT_INC_APPL_0000_DATA TYPE STANDARD TABLE OF FDT_INC_APPL_0000_DATA, WA_FDT_INC_APPL_0000_DATA TYPE FDT_INC_APPL_0000_DATA, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <FDT_INC_APPL_0000_DATA> TYPE FDT_INC_APPL_0000_DATA. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_FDT_INC_APPL_0000_DATA. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM FDT_INC_APPL_0000_DATA INTO TABLE IT_FDT_INC_APPL_0000_DATA. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM FDT_INC_APPL_0000_DATA * INTO TABLE @DATA(IT_FDT_INC_APPL_0000_DATA2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_FDT_INC_APPL_0000_DATA INDEX 1 INTO DATA(WA_FDT_INC_APPL_0000_DATA2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_FDT_INC_APPL_0000_DATA ASSIGNING <FDT_INC_APPL_0000_DATA>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<FDT_INC_APPL_0000_DATA>-APPLICATION_COMP = 1.
<FDT_INC_APPL_0000_DATA>-SOFTWARE_COMP = 1.
<FDT_INC_APPL_0000_DATA>-SETTINGS_CLASS = 1.
<FDT_INC_APPL_0000_DATA>-DEVEL_PACKAGE = 1.
<FDT_INC_APPL_0000_DATA>-LOG_OBJECT = 1.
ENDLOOP. LOOP AT IT_FDT_INC_APPL_0000_DATA INTO WA_FDT_INC_APPL_0000_DATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_FDT_INC_APPL_0000_DATA-LOG_SUBOBJECT, sy-vline,
WA_FDT_INC_APPL_0000_DATA-PERSIST_LOG, sy-vline,
WA_FDT_INC_APPL_0000_DATA-LOG_CONSTRAINT, sy-vline,
WA_FDT_INC_APPL_0000_DATA-VERSIONING_MODE, sy-vline,
WA_FDT_INC_APPL_0000_DATA-RULESET_RESTART, sy-vline,
WA_FDT_INC_APPL_0000_DATA-TEXT_DEP_TYPE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FDT_INC_APPL_0000_DATA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FDT_INC_APPL_0000_DATA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FDT_INC_APPL_0000_DATA INTO WA_FDT_INC_APPL_0000_DATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FDT_INC_APPL_0000_DATA_STR,
APPLICATION_COMP TYPE STRING,
SOFTWARE_COMP TYPE STRING,
SETTINGS_CLASS TYPE STRING,
DEVEL_PACKAGE TYPE STRING,
LOG_OBJECT TYPE STRING,
LOG_SUBOBJECT TYPE STRING,
PERSIST_LOG TYPE STRING,
LOG_CONSTRAINT TYPE STRING,
VERSIONING_MODE TYPE STRING,
RULESET_RESTART TYPE STRING,
TEXT_DEP_TYPE TYPE STRING,
DOCU_DEP_TYPE TYPE STRING,
HIDE_EXTERNAL_ID TYPE STRING,
DENIED_MSG_TYPES TYPE STRING,
DBCON_NAME TYPE STRING,
APPL_CURR TYPE STRING,
CURR_CHECK_SEV TYPE STRING,
CATTR1_DOBJ TYPE STRING,
CATTR1_TYPE TYPE STRING,
CATTR2_DOBJ TYPE STRING,
CATTR2_TYPE TYPE STRING,
CATTR3_DOBJ TYPE STRING,
CATTR3_TYPE TYPE STRING,
CATTR4_DOBJ TYPE STRING,
CATTR4_TYPE TYPE STRING,
CATTR5_DOBJ TYPE STRING,
CATTR5_TYPE TYPE STRING,
CATTR6_DOBJ TYPE STRING,
CATTR6_TYPE TYPE STRING,
CATTR7_DOBJ TYPE STRING,
CATTR7_TYPE TYPE STRING,
CATTR8_DOBJ TYPE STRING,
CATTR8_TYPE TYPE STRING,
NUMC_INT_COMPARE TYPE STRING,
PROB_CLASS TYPE STRING,END OF T_EKKO_STR. DATA: WA_FDT_INC_APPL_0000_DATA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FDT_INC_APPL_0000_DATA_STR-APPLICATION_COMP sy-vline
WA_FDT_INC_APPL_0000_DATA_STR-SOFTWARE_COMP sy-vline
WA_FDT_INC_APPL_0000_DATA_STR-SETTINGS_CLASS sy-vline
WA_FDT_INC_APPL_0000_DATA_STR-DEVEL_PACKAGE sy-vline
WA_FDT_INC_APPL_0000_DATA_STR-LOG_OBJECT sy-vline
WA_FDT_INC_APPL_0000_DATA_STR-LOG_SUBOBJECT sy-vline
WA_FDT_INC_APPL_0000_DATA_STR-PERSIST_LOG sy-vline
WA_FDT_INC_APPL_0000_DATA_STR-LOG_CONSTRAINT sy-vline
WA_FDT_INC_APPL_0000_DATA_STR-VERSIONING_MODE sy-vline
WA_FDT_INC_APPL_0000_DATA_STR-RULESET_RESTART sy-vline
WA_FDT_INC_APPL_0000_DATA_STR-TEXT_DEP_TYPE sy-vline
WA_FDT_INC_APPL_0000_DATA_STR-DOCU_DEP_TYPE sy-vline
WA_FDT_INC_APPL_0000_DATA_STR-HIDE_EXTERNAL_ID sy-vline
WA_FDT_INC_APPL_0000_DATA_STR-DENIED_MSG_TYPES sy-vline
WA_FDT_INC_APPL_0000_DATA_STR-DBCON_NAME sy-vline
WA_FDT_INC_APPL_0000_DATA_STR-APPL_CURR sy-vline
WA_FDT_INC_APPL_0000_DATA_STR-CURR_CHECK_SEV sy-vline
WA_FDT_INC_APPL_0000_DATA_STR-CATTR1_DOBJ sy-vline
WA_FDT_INC_APPL_0000_DATA_STR-CATTR1_TYPE sy-vline
WA_FDT_INC_APPL_0000_DATA_STR-CATTR2_DOBJ sy-vline
WA_FDT_INC_APPL_0000_DATA_STR-CATTR2_TYPE sy-vline
WA_FDT_INC_APPL_0000_DATA_STR-CATTR3_DOBJ sy-vline
WA_FDT_INC_APPL_0000_DATA_STR-CATTR3_TYPE sy-vline
WA_FDT_INC_APPL_0000_DATA_STR-CATTR4_DOBJ sy-vline
WA_FDT_INC_APPL_0000_DATA_STR-CATTR4_TYPE sy-vline
WA_FDT_INC_APPL_0000_DATA_STR-CATTR5_DOBJ sy-vline
WA_FDT_INC_APPL_0000_DATA_STR-CATTR5_TYPE sy-vline
WA_FDT_INC_APPL_0000_DATA_STR-CATTR6_DOBJ sy-vline
WA_FDT_INC_APPL_0000_DATA_STR-CATTR6_TYPE sy-vline
WA_FDT_INC_APPL_0000_DATA_STR-CATTR7_DOBJ sy-vline
WA_FDT_INC_APPL_0000_DATA_STR-CATTR7_TYPE sy-vline
WA_FDT_INC_APPL_0000_DATA_STR-CATTR8_DOBJ sy-vline
WA_FDT_INC_APPL_0000_DATA_STR-CATTR8_TYPE sy-vline
WA_FDT_INC_APPL_0000_DATA_STR-NUMC_INT_COMPARE sy-vline
WA_FDT_INC_APPL_0000_DATA_STR-PROB_CLASS sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.