ABAP Select data from SAP table FERC_C0 into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP FERC_C0 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FERC_C0. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the FERC_C0 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_FERC_C0 TYPE STANDARD TABLE OF FERC_C0, WA_FERC_C0 TYPE FERC_C0, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <FERC_C0> TYPE FERC_C0. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_FERC_C0. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM FERC_C0 INTO TABLE IT_FERC_C0. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM FERC_C0 * INTO TABLE @DATA(IT_FERC_C02). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_FERC_C0 INDEX 1 INTO DATA(WA_FERC_C02). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_FERC_C0 ASSIGNING <FERC_C0>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<FERC_C0>-MANDT = 1.
<FERC_C0>-IGN_SCE = 1.
<FERC_C0>-EXT_SET = 1.
<FERC_C0>-NREG_CLRG = 1.
<FERC_C0>-NWA_WBS = 1.
ENDLOOP. LOOP AT IT_FERC_C0 INTO WA_FERC_C0. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_FERC_C0-NO_ZERO, sy-vline,
WA_FERC_C0-HOR_COR, sy-vline,
WA_FERC_C0-THRESHOLD, sy-vline,
WA_FERC_C0-WAIT, sy-vline,
WA_FERC_C0-BTCSYSTEM, sy-vline,
WA_FERC_C0-PRCTR_TRC_0, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FERC_C0 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FERC_C0 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FERC_C0 INTO WA_FERC_C0. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field RLDNR_FROM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FERC_C0-RLDNR_FROM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FERC_C0-RLDNR_FROM.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field RLDNR_TO_1 CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FERC_C0-RLDNR_TO_1 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FERC_C0-RLDNR_TO_1.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FERC_C0_STR,
MANDT TYPE STRING,
IGN_SCE TYPE STRING,
EXT_SET TYPE STRING,
NREG_CLRG TYPE STRING,
NWA_WBS TYPE STRING,
NO_ZERO TYPE STRING,
HOR_COR TYPE STRING,
THRESHOLD TYPE STRING,
WAIT TYPE STRING,
BTCSYSTEM TYPE STRING,
PRCTR_TRC_0 TYPE STRING,
PRCTR_TRC_1 TYPE STRING,
PRCTR_DIR_0 TYPE STRING,
PRCTR_DIR_1 TYPE STRING,
RLDNR_FROM TYPE STRING,
RLDNR_TO_1 TYPE STRING,
LOG_AMODAL TYPE STRING,
LOG_GRID TYPE STRING,
REP_GRID TYPE STRING,
PATHS_MAX TYPE STRING,END OF T_EKKO_STR. DATA: WA_FERC_C0_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FERC_C0_STR-MANDT sy-vline
WA_FERC_C0_STR-IGN_SCE sy-vline
WA_FERC_C0_STR-EXT_SET sy-vline
WA_FERC_C0_STR-NREG_CLRG sy-vline
WA_FERC_C0_STR-NWA_WBS sy-vline
WA_FERC_C0_STR-NO_ZERO sy-vline
WA_FERC_C0_STR-HOR_COR sy-vline
WA_FERC_C0_STR-THRESHOLD sy-vline
WA_FERC_C0_STR-WAIT sy-vline
WA_FERC_C0_STR-BTCSYSTEM sy-vline
WA_FERC_C0_STR-PRCTR_TRC_0 sy-vline
WA_FERC_C0_STR-PRCTR_TRC_1 sy-vline
WA_FERC_C0_STR-PRCTR_DIR_0 sy-vline
WA_FERC_C0_STR-PRCTR_DIR_1 sy-vline
WA_FERC_C0_STR-RLDNR_FROM sy-vline
WA_FERC_C0_STR-RLDNR_TO_1 sy-vline
WA_FERC_C0_STR-LOG_AMODAL sy-vline
WA_FERC_C0_STR-LOG_GRID sy-vline
WA_FERC_C0_STR-REP_GRID sy-vline
WA_FERC_C0_STR-PATHS_MAX sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.