ABAP Select data from SAP table FIAU_S_PTR_OUTPUT into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP FIAU_S_PTR_OUTPUT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FIAU_S_PTR_OUTPUT. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the FIAU_S_PTR_OUTPUT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_FIAU_S_PTR_OUTPUT TYPE STANDARD TABLE OF FIAU_S_PTR_OUTPUT, WA_FIAU_S_PTR_OUTPUT TYPE FIAU_S_PTR_OUTPUT, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <FIAU_S_PTR_OUTPUT> TYPE FIAU_S_PTR_OUTPUT. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_FIAU_S_PTR_OUTPUT. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM FIAU_S_PTR_OUTPUT INTO TABLE IT_FIAU_S_PTR_OUTPUT. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM FIAU_S_PTR_OUTPUT * INTO TABLE @DATA(IT_FIAU_S_PTR_OUTPUT2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_FIAU_S_PTR_OUTPUT INDEX 1 INTO DATA(WA_FIAU_S_PTR_OUTPUT2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_FIAU_S_PTR_OUTPUT ASSIGNING <FIAU_S_PTR_OUTPUT>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<FIAU_S_PTR_OUTPUT>-ENTITY_INFO = 1.
<FIAU_S_PTR_OUTPUT>-NAME = 1.
<FIAU_S_PTR_OUTPUT>-ABN = 1.
<FIAU_S_PTR_OUTPUT>-CONTROLLING_NAME = 1.
<FIAU_S_PTR_OUTPUT>-CONTROLLING_ABN = 1.
ENDLOOP. LOOP AT IT_FIAU_S_PTR_OUTPUT INTO WA_FIAU_S_PTR_OUTPUT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_FIAU_S_PTR_OUTPUT-HEAD_NAME, sy-vline,
WA_FIAU_S_PTR_OUTPUT-HEAD_ABN, sy-vline,
WA_FIAU_S_PTR_OUTPUT-PRIMARY_INDUSTRY, sy-vline,
WA_FIAU_S_PTR_OUTPUT-SUBMITTERS_NAME, sy-vline,
WA_FIAU_S_PTR_OUTPUT-SUBMITTERS_DESG, sy-vline,
WA_FIAU_S_PTR_OUTPUT-SUBMITTERS_PHONE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FIAU_S_PTR_OUTPUT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FIAU_S_PTR_OUTPUT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FIAU_S_PTR_OUTPUT INTO WA_FIAU_S_PTR_OUTPUT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FIAU_S_PTR_OUTPUT_STR,
ENTITY_INFO TYPE STRING,
NAME TYPE STRING,
ABN TYPE STRING,
CONTROLLING_NAME TYPE STRING,
CONTROLLING_ABN TYPE STRING,
HEAD_NAME TYPE STRING,
HEAD_ABN TYPE STRING,
PRIMARY_INDUSTRY TYPE STRING,
SUBMITTERS_NAME TYPE STRING,
SUBMITTERS_DESG TYPE STRING,
SUBMITTERS_PHONE TYPE STRING,
SUBMITTERS_EMAIL TYPE STRING,
APPROVERS_NAME TYPE STRING,
DATE_OF_APPROVAL TYPE STRING,
GOVERNING_BODY_NAME TYPE STRING,
RESPONSIBLE_MEMBER TYPE STRING,
DECLARATION_DATE TYPE STRING,
PAYMENT_DATA TYPE STRING,
REPORTING_PERIOD TYPE STRING,
SHORTEST_SPP TYPE STRING,
LONGEST_SPP TYPE STRING,
NUM_INV_PAID_WITHIN_20 TYPE STRING,
SUM_INV_PAID_WITHIN_20 TYPE STRING,
NUM_INV_PAID_21_30 TYPE STRING,
SUM_INV_PAID_21_30 TYPE STRING,
NUM_INV_PAID_31_60 TYPE STRING,
SUM_INV_PAID_31_60 TYPE STRING,
NUM_INV_PAID_61_90 TYPE STRING,
SUM_INV_PAID_61_90 TYPE STRING,
NUM_INV_PAID_91_120 TYPE STRING,
SUM_INV_PAID_91_120 TYPE STRING,
NUM_INV_PAID_GT_120 TYPE STRING,
SUM_INV_PAID_GT_120 TYPE STRING,
SMALL_BUSINESS_PAYMENT_PROP TYPE STRING,
NUM_INV_PAID_SCFA TYPE STRING,
SUM_INV_PAID_SCFA TYPE STRING,
OTHER_DATA TYPE STRING,
SMALL_BUSINESS_INVOICES TYPE STRING,
SMALL_BUSINESS_PRACTICES TYPE STRING,
NOTIFIABLE_EVENTS TYPE STRING,
ADDITIONAL_INFORMATION TYPE STRING,END OF T_EKKO_STR. DATA: WA_FIAU_S_PTR_OUTPUT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FIAU_S_PTR_OUTPUT_STR-ENTITY_INFO sy-vline
WA_FIAU_S_PTR_OUTPUT_STR-NAME sy-vline
WA_FIAU_S_PTR_OUTPUT_STR-ABN sy-vline
WA_FIAU_S_PTR_OUTPUT_STR-CONTROLLING_NAME sy-vline
WA_FIAU_S_PTR_OUTPUT_STR-CONTROLLING_ABN sy-vline
WA_FIAU_S_PTR_OUTPUT_STR-HEAD_NAME sy-vline
WA_FIAU_S_PTR_OUTPUT_STR-HEAD_ABN sy-vline
WA_FIAU_S_PTR_OUTPUT_STR-PRIMARY_INDUSTRY sy-vline
WA_FIAU_S_PTR_OUTPUT_STR-SUBMITTERS_NAME sy-vline
WA_FIAU_S_PTR_OUTPUT_STR-SUBMITTERS_DESG sy-vline
WA_FIAU_S_PTR_OUTPUT_STR-SUBMITTERS_PHONE sy-vline
WA_FIAU_S_PTR_OUTPUT_STR-SUBMITTERS_EMAIL sy-vline
WA_FIAU_S_PTR_OUTPUT_STR-APPROVERS_NAME sy-vline
WA_FIAU_S_PTR_OUTPUT_STR-DATE_OF_APPROVAL sy-vline
WA_FIAU_S_PTR_OUTPUT_STR-GOVERNING_BODY_NAME sy-vline
WA_FIAU_S_PTR_OUTPUT_STR-RESPONSIBLE_MEMBER sy-vline
WA_FIAU_S_PTR_OUTPUT_STR-DECLARATION_DATE sy-vline
WA_FIAU_S_PTR_OUTPUT_STR-PAYMENT_DATA sy-vline
WA_FIAU_S_PTR_OUTPUT_STR-REPORTING_PERIOD sy-vline
WA_FIAU_S_PTR_OUTPUT_STR-SHORTEST_SPP sy-vline
WA_FIAU_S_PTR_OUTPUT_STR-LONGEST_SPP sy-vline
WA_FIAU_S_PTR_OUTPUT_STR-NUM_INV_PAID_WITHIN_20 sy-vline
WA_FIAU_S_PTR_OUTPUT_STR-SUM_INV_PAID_WITHIN_20 sy-vline
WA_FIAU_S_PTR_OUTPUT_STR-NUM_INV_PAID_21_30 sy-vline
WA_FIAU_S_PTR_OUTPUT_STR-SUM_INV_PAID_21_30 sy-vline
WA_FIAU_S_PTR_OUTPUT_STR-NUM_INV_PAID_31_60 sy-vline
WA_FIAU_S_PTR_OUTPUT_STR-SUM_INV_PAID_31_60 sy-vline
WA_FIAU_S_PTR_OUTPUT_STR-NUM_INV_PAID_61_90 sy-vline
WA_FIAU_S_PTR_OUTPUT_STR-SUM_INV_PAID_61_90 sy-vline
WA_FIAU_S_PTR_OUTPUT_STR-NUM_INV_PAID_91_120 sy-vline
WA_FIAU_S_PTR_OUTPUT_STR-SUM_INV_PAID_91_120 sy-vline
WA_FIAU_S_PTR_OUTPUT_STR-NUM_INV_PAID_GT_120 sy-vline
WA_FIAU_S_PTR_OUTPUT_STR-SUM_INV_PAID_GT_120 sy-vline
WA_FIAU_S_PTR_OUTPUT_STR-SMALL_BUSINESS_PAYMENT_PROP sy-vline
WA_FIAU_S_PTR_OUTPUT_STR-NUM_INV_PAID_SCFA sy-vline
WA_FIAU_S_PTR_OUTPUT_STR-SUM_INV_PAID_SCFA sy-vline
WA_FIAU_S_PTR_OUTPUT_STR-OTHER_DATA sy-vline
WA_FIAU_S_PTR_OUTPUT_STR-SMALL_BUSINESS_INVOICES sy-vline
WA_FIAU_S_PTR_OUTPUT_STR-SMALL_BUSINESS_PRACTICES sy-vline
WA_FIAU_S_PTR_OUTPUT_STR-NOTIFIABLE_EVENTS sy-vline
WA_FIAU_S_PTR_OUTPUT_STR-ADDITIONAL_INFORMATION sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.