ABAP Select data from SAP table FINS_UNIT_MOCKUP_RFC into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FINS_UNIT_MOCKUP_RFC table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FINS_UNIT_MOCKUP_RFC. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FINS_UNIT_MOCKUP_RFC table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FINS_UNIT_MOCKUP_RFC TYPE STANDARD TABLE OF FINS_UNIT_MOCKUP_RFC,
      WA_FINS_UNIT_MOCKUP_RFC TYPE FINS_UNIT_MOCKUP_RFC,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FINS_UNIT_MOCKUP_RFC> TYPE FINS_UNIT_MOCKUP_RFC.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FINS_UNIT_MOCKUP_RFC.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FINS_UNIT_MOCKUP_RFC
  INTO TABLE IT_FINS_UNIT_MOCKUP_RFC.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FINS_UNIT_MOCKUP_RFC
*  INTO TABLE @DATA(IT_FINS_UNIT_MOCKUP_RFC2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FINS_UNIT_MOCKUP_RFC INDEX 1 INTO DATA(WA_FINS_UNIT_MOCKUP_RFC2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FINS_UNIT_MOCKUP_RFC ASSIGNING <FINS_UNIT_MOCKUP_RFC>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FINS_UNIT_MOCKUP_RFC>-IS_ACTIVE = 1.
<FINS_UNIT_MOCKUP_RFC>-COGS_SPLIT_POST_IS_ACTIVE = 1.
<FINS_UNIT_MOCKUP_RFC>-COGS_SPLIT_PROD_CALC = 1.
<FINS_UNIT_MOCKUP_RFC>-PR_COST_KEY = 1.
<FINS_UNIT_MOCKUP_RFC>-COST_COMP = 1.
ENDLOOP.

LOOP AT IT_FINS_UNIT_MOCKUP_RFC INTO WA_FINS_UNIT_MOCKUP_RFC.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FINS_UNIT_MOCKUP_RFC-COST_COMP_CURTP, sy-vline,
WA_FINS_UNIT_MOCKUP_RFC-CURTP_INFO, sy-vline,
WA_FINS_UNIT_MOCKUP_RFC-SPLIT_FACTOR, sy-vline,
WA_FINS_UNIT_MOCKUP_RFC-UT_SPLIT_FACTOR_CURTP, sy-vline,
WA_FINS_UNIT_MOCKUP_RFC-T_ACTUAL_CCS, sy-vline,
WA_FINS_UNIT_MOCKUP_RFC-CFIN_COST_COMP, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FINS_UNIT_MOCKUP_RFC you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FINS_UNIT_MOCKUP_RFC TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FINS_UNIT_MOCKUP_RFC INTO WA_FINS_UNIT_MOCKUP_RFC. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FINS_UNIT_MOCKUP_RFC_STR,
IS_ACTIVE TYPE STRING,
COGS_SPLIT_POST_IS_ACTIVE TYPE STRING,
COGS_SPLIT_PROD_CALC TYPE STRING,
PR_COST_KEY TYPE STRING,
COST_COMP TYPE STRING,
COST_COMP_CURTP TYPE STRING,
CURTP_INFO TYPE STRING,
SPLIT_FACTOR TYPE STRING,
UT_SPLIT_FACTOR_CURTP TYPE STRING,
T_ACTUAL_CCS TYPE STRING,
CFIN_COST_COMP TYPE STRING,
T_CKMLHD TYPE STRING,
T_PRKEKO TYPE STRING,
T_PRKEPH TYPE STRING,
PRED_ITEM_CAT_MOCKUP_DATA TYPE STRING,
PRED_API_IS_ACTIVE TYPE STRING,END OF T_EKKO_STR. DATA: WA_FINS_UNIT_MOCKUP_RFC_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FINS_UNIT_MOCKUP_RFC_STR-IS_ACTIVE sy-vline
WA_FINS_UNIT_MOCKUP_RFC_STR-COGS_SPLIT_POST_IS_ACTIVE sy-vline
WA_FINS_UNIT_MOCKUP_RFC_STR-COGS_SPLIT_PROD_CALC sy-vline
WA_FINS_UNIT_MOCKUP_RFC_STR-PR_COST_KEY sy-vline
WA_FINS_UNIT_MOCKUP_RFC_STR-COST_COMP sy-vline
WA_FINS_UNIT_MOCKUP_RFC_STR-COST_COMP_CURTP sy-vline
WA_FINS_UNIT_MOCKUP_RFC_STR-CURTP_INFO sy-vline
WA_FINS_UNIT_MOCKUP_RFC_STR-SPLIT_FACTOR sy-vline
WA_FINS_UNIT_MOCKUP_RFC_STR-UT_SPLIT_FACTOR_CURTP sy-vline
WA_FINS_UNIT_MOCKUP_RFC_STR-T_ACTUAL_CCS sy-vline
WA_FINS_UNIT_MOCKUP_RFC_STR-CFIN_COST_COMP sy-vline
WA_FINS_UNIT_MOCKUP_RFC_STR-T_CKMLHD sy-vline
WA_FINS_UNIT_MOCKUP_RFC_STR-T_PRKEKO sy-vline
WA_FINS_UNIT_MOCKUP_RFC_STR-T_PRKEPH sy-vline
WA_FINS_UNIT_MOCKUP_RFC_STR-PRED_ITEM_CAT_MOCKUP_DATA sy-vline
WA_FINS_UNIT_MOCKUP_RFC_STR-PRED_API_IS_ACTIVE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.