ABAP Select data from SAP table FINSV_T001_WO_AD into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FINSV_T001_WO_AD table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FINSV_T001_WO_AD. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FINSV_T001_WO_AD table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FINSV_T001_WO_AD TYPE STANDARD TABLE OF FINSV_T001_WO_AD,
      WA_FINSV_T001_WO_AD TYPE FINSV_T001_WO_AD,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FINSV_T001_WO_AD> TYPE FINSV_T001_WO_AD.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FINSV_T001_WO_AD.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FINSV_T001_WO_AD
  INTO TABLE IT_FINSV_T001_WO_AD.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FINSV_T001_WO_AD
*  INTO TABLE @DATA(IT_FINSV_T001_WO_AD2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FINSV_T001_WO_AD INDEX 1 INTO DATA(WA_FINSV_T001_WO_AD2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FINSV_T001_WO_AD ASSIGNING <FINSV_T001_WO_AD>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FINSV_T001_WO_AD>-MANDT = 1.
<FINSV_T001_WO_AD>-BUKRS = 1.
<FINSV_T001_WO_AD>-BUTXT = 1.
<FINSV_T001_WO_AD>-ORT01 = 1.
<FINSV_T001_WO_AD>-LAND1 = 1.
ENDLOOP.

LOOP AT IT_FINSV_T001_WO_AD INTO WA_FINSV_T001_WO_AD.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FINSV_T001_WO_AD-WAERS, sy-vline,
WA_FINSV_T001_WO_AD-SPRAS, sy-vline,
WA_FINSV_T001_WO_AD-KTOPL, sy-vline,
WA_FINSV_T001_WO_AD-WAABW, sy-vline,
WA_FINSV_T001_WO_AD-PERIV, sy-vline,
WA_FINSV_T001_WO_AD-KOKFI, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FINSV_T001_WO_AD you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FINSV_T001_WO_AD TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FINSV_T001_WO_AD INTO WA_FINSV_T001_WO_AD. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ISOLA, internal->external for field SPRAS CALL FUNCTION 'CONVERSION_EXIT_ISOLA_OUTPUT' EXPORTING input = WA_FINSV_T001_WO_AD-SPRAS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FINSV_T001_WO_AD-SPRAS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RCOMP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FINSV_T001_WO_AD-RCOMP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FINSV_T001_WO_AD-RCOMP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field INFMT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FINSV_T001_WO_AD-INFMT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FINSV_T001_WO_AD-INFMT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FINSV_T001_WO_AD_STR,
MANDT TYPE STRING,
BUKRS TYPE STRING,
BUTXT TYPE STRING,
ORT01 TYPE STRING,
LAND1 TYPE STRING,
WAERS TYPE STRING,
SPRAS TYPE STRING,
KTOPL TYPE STRING,
WAABW TYPE STRING,
PERIV TYPE STRING,
KOKFI TYPE STRING,
RCOMP TYPE STRING,
STCEG TYPE STRING,
FIKRS TYPE STRING,
XFMCO TYPE STRING,
XFMCB TYPE STRING,
XFMCA TYPE STRING,
TXJCD TYPE STRING,
FMHRDATE TYPE STRING,
XTEMPLT TYPE STRING,
BUVAR TYPE STRING,
FDBUK TYPE STRING,
XFDIS TYPE STRING,
XVALV TYPE STRING,
XSKFN TYPE STRING,
KKBER TYPE STRING,
XMWSN TYPE STRING,
MREGL TYPE STRING,
XGSBE TYPE STRING,
XGJRV TYPE STRING,
XKDFT TYPE STRING,
XPROD TYPE STRING,
XEINK TYPE STRING,
XJVAA TYPE STRING,
XVVWA TYPE STRING,
XSLTA TYPE STRING,
XFDMM TYPE STRING,
XFDSD TYPE STRING,
XEXTB TYPE STRING,
EBUKR TYPE STRING,
KTOP2 TYPE STRING,
UMKRS TYPE STRING,
BUKRS_GLOB TYPE STRING,
FSTVA TYPE STRING,
OPVAR TYPE STRING,
XCOVR TYPE STRING,
TXKRS TYPE STRING,
WFVAR TYPE STRING,
XBBBF TYPE STRING,
XBBBE TYPE STRING,
XBBBA TYPE STRING,
XBBKO TYPE STRING,
XSTDT TYPE STRING,
MWSKV TYPE STRING,
MWSKA TYPE STRING,
IMPDA TYPE STRING,
XNEGP TYPE STRING,
XKKBI TYPE STRING,
WT_NEWWT TYPE STRING,
PP_PDATE TYPE STRING,
INFMT TYPE STRING,
FSTVARE TYPE STRING,
KOPIM TYPE STRING,
DKWEG TYPE STRING,
OFFSACCT TYPE STRING,
BAPOVAR TYPE STRING,
XCOS TYPE STRING,
XCESSION TYPE STRING,
XSPLT TYPE STRING,
SURCCM TYPE STRING,
DTPROV TYPE STRING,
DTAMTC TYPE STRING,
DTTAXC TYPE STRING,
DTTDSP TYPE STRING,
DTAXR TYPE STRING,
XVATDATE TYPE STRING,
PST_PER_VAR TYPE STRING,
XBBSC TYPE STRING,END OF T_EKKO_STR. DATA: WA_FINSV_T001_WO_AD_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FINSV_T001_WO_AD_STR-MANDT sy-vline
WA_FINSV_T001_WO_AD_STR-BUKRS sy-vline
WA_FINSV_T001_WO_AD_STR-BUTXT sy-vline
WA_FINSV_T001_WO_AD_STR-ORT01 sy-vline
WA_FINSV_T001_WO_AD_STR-LAND1 sy-vline
WA_FINSV_T001_WO_AD_STR-WAERS sy-vline
WA_FINSV_T001_WO_AD_STR-SPRAS sy-vline
WA_FINSV_T001_WO_AD_STR-KTOPL sy-vline
WA_FINSV_T001_WO_AD_STR-WAABW sy-vline
WA_FINSV_T001_WO_AD_STR-PERIV sy-vline
WA_FINSV_T001_WO_AD_STR-KOKFI sy-vline
WA_FINSV_T001_WO_AD_STR-RCOMP sy-vline
WA_FINSV_T001_WO_AD_STR-STCEG sy-vline
WA_FINSV_T001_WO_AD_STR-FIKRS sy-vline
WA_FINSV_T001_WO_AD_STR-XFMCO sy-vline
WA_FINSV_T001_WO_AD_STR-XFMCB sy-vline
WA_FINSV_T001_WO_AD_STR-XFMCA sy-vline
WA_FINSV_T001_WO_AD_STR-TXJCD sy-vline
WA_FINSV_T001_WO_AD_STR-FMHRDATE sy-vline
WA_FINSV_T001_WO_AD_STR-XTEMPLT sy-vline
WA_FINSV_T001_WO_AD_STR-BUVAR sy-vline
WA_FINSV_T001_WO_AD_STR-FDBUK sy-vline
WA_FINSV_T001_WO_AD_STR-XFDIS sy-vline
WA_FINSV_T001_WO_AD_STR-XVALV sy-vline
WA_FINSV_T001_WO_AD_STR-XSKFN sy-vline
WA_FINSV_T001_WO_AD_STR-KKBER sy-vline
WA_FINSV_T001_WO_AD_STR-XMWSN sy-vline
WA_FINSV_T001_WO_AD_STR-MREGL sy-vline
WA_FINSV_T001_WO_AD_STR-XGSBE sy-vline
WA_FINSV_T001_WO_AD_STR-XGJRV sy-vline
WA_FINSV_T001_WO_AD_STR-XKDFT sy-vline
WA_FINSV_T001_WO_AD_STR-XPROD sy-vline
WA_FINSV_T001_WO_AD_STR-XEINK sy-vline
WA_FINSV_T001_WO_AD_STR-XJVAA sy-vline
WA_FINSV_T001_WO_AD_STR-XVVWA sy-vline
WA_FINSV_T001_WO_AD_STR-XSLTA sy-vline
WA_FINSV_T001_WO_AD_STR-XFDMM sy-vline
WA_FINSV_T001_WO_AD_STR-XFDSD sy-vline
WA_FINSV_T001_WO_AD_STR-XEXTB sy-vline
WA_FINSV_T001_WO_AD_STR-EBUKR sy-vline
WA_FINSV_T001_WO_AD_STR-KTOP2 sy-vline
WA_FINSV_T001_WO_AD_STR-UMKRS sy-vline
WA_FINSV_T001_WO_AD_STR-BUKRS_GLOB sy-vline
WA_FINSV_T001_WO_AD_STR-FSTVA sy-vline
WA_FINSV_T001_WO_AD_STR-OPVAR sy-vline
WA_FINSV_T001_WO_AD_STR-XCOVR sy-vline
WA_FINSV_T001_WO_AD_STR-TXKRS sy-vline
WA_FINSV_T001_WO_AD_STR-WFVAR sy-vline
WA_FINSV_T001_WO_AD_STR-XBBBF sy-vline
WA_FINSV_T001_WO_AD_STR-XBBBE sy-vline
WA_FINSV_T001_WO_AD_STR-XBBBA sy-vline
WA_FINSV_T001_WO_AD_STR-XBBKO sy-vline
WA_FINSV_T001_WO_AD_STR-XSTDT sy-vline
WA_FINSV_T001_WO_AD_STR-MWSKV sy-vline
WA_FINSV_T001_WO_AD_STR-MWSKA sy-vline
WA_FINSV_T001_WO_AD_STR-IMPDA sy-vline
WA_FINSV_T001_WO_AD_STR-XNEGP sy-vline
WA_FINSV_T001_WO_AD_STR-XKKBI sy-vline
WA_FINSV_T001_WO_AD_STR-WT_NEWWT sy-vline
WA_FINSV_T001_WO_AD_STR-PP_PDATE sy-vline
WA_FINSV_T001_WO_AD_STR-INFMT sy-vline
WA_FINSV_T001_WO_AD_STR-FSTVARE sy-vline
WA_FINSV_T001_WO_AD_STR-KOPIM sy-vline
WA_FINSV_T001_WO_AD_STR-DKWEG sy-vline
WA_FINSV_T001_WO_AD_STR-OFFSACCT sy-vline
WA_FINSV_T001_WO_AD_STR-BAPOVAR sy-vline
WA_FINSV_T001_WO_AD_STR-XCOS sy-vline
WA_FINSV_T001_WO_AD_STR-XCESSION sy-vline
WA_FINSV_T001_WO_AD_STR-XSPLT sy-vline
WA_FINSV_T001_WO_AD_STR-SURCCM sy-vline
WA_FINSV_T001_WO_AD_STR-DTPROV sy-vline
WA_FINSV_T001_WO_AD_STR-DTAMTC sy-vline
WA_FINSV_T001_WO_AD_STR-DTTAXC sy-vline
WA_FINSV_T001_WO_AD_STR-DTTDSP sy-vline
WA_FINSV_T001_WO_AD_STR-DTAXR sy-vline
WA_FINSV_T001_WO_AD_STR-XVATDATE sy-vline
WA_FINSV_T001_WO_AD_STR-PST_PER_VAR sy-vline
WA_FINSV_T001_WO_AD_STR-XBBSC sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.