ABAP Select data from SAP table FIRUD_PRT_RPITM into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP FIRUD_PRT_RPITM table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FIRUD_PRT_RPITM. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the FIRUD_PRT_RPITM table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_FIRUD_PRT_RPITM TYPE STANDARD TABLE OF FIRUD_PRT_RPITM, WA_FIRUD_PRT_RPITM TYPE FIRUD_PRT_RPITM, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <FIRUD_PRT_RPITM> TYPE FIRUD_PRT_RPITM. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_FIRUD_PRT_RPITM. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM FIRUD_PRT_RPITM INTO TABLE IT_FIRUD_PRT_RPITM. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM FIRUD_PRT_RPITM * INTO TABLE @DATA(IT_FIRUD_PRT_RPITM2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_FIRUD_PRT_RPITM INDEX 1 INTO DATA(WA_FIRUD_PRT_RPITM2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_FIRUD_PRT_RPITM ASSIGNING <FIRUD_PRT_RPITM>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<FIRUD_PRT_RPITM>-MANDT = 1.
<FIRUD_PRT_RPITM>-STATRYRPTGENTITY = 1.
<FIRUD_PRT_RPITM>-STATRYRPTCATEGORY = 1.
<FIRUD_PRT_RPITM>-STATRYRPTRUNID = 1.
<FIRUD_PRT_RPITM>-ITEMID = 1.
ENDLOOP. LOOP AT IT_FIRUD_PRT_RPITM INTO WA_FIRUD_PRT_RPITM. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_FIRUD_PRT_RPITM-COMPANYCODE, sy-vline,
WA_FIRUD_PRT_RPITM-MASTERFIXEDASSET, sy-vline,
WA_FIRUD_PRT_RPITM-FIXEDASSET, sy-vline,
WA_FIRUD_PRT_RPITM-INTERVALSTART, sy-vline,
WA_FIRUD_PRT_RPITM-INTERVALEND, sy-vline,
WA_FIRUD_PRT_RPITM-OKTMO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FIRUD_PRT_RPITM you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FIRUD_PRT_RPITM TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FIRUD_PRT_RPITM INTO WA_FIRUD_PRT_RPITM. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field MASTERFIXEDASSET CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FIRUD_PRT_RPITM-MASTERFIXEDASSET IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FIRUD_PRT_RPITM-MASTERFIXEDASSET.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field FIXEDASSET CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FIRUD_PRT_RPITM-FIXEDASSET IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FIRUD_PRT_RPITM-FIXEDASSET.
WRITE:/ 'New Value:', ld_input.
*Conversion exit OKTMO, internal->external for field OKTMO CALL FUNCTION 'CONVERSION_EXIT_OKTMO_OUTPUT' EXPORTING input = WA_FIRUD_PRT_RPITM-OKTMO IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FIRUD_PRT_RPITM-OKTMO.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FIRUD_PRT_RPITM_STR,
MANDT TYPE STRING,
STATRYRPTGENTITY TYPE STRING,
STATRYRPTCATEGORY TYPE STRING,
STATRYRPTRUNID TYPE STRING,
ITEMID TYPE STRING,
COMPANYCODE TYPE STRING,
MASTERFIXEDASSET TYPE STRING,
FIXEDASSET TYPE STRING,
INTERVALSTART TYPE STRING,
INTERVALEND TYPE STRING,
OKTMO TYPE STRING,
PROPERTYTYPE TYPE STRING,
NBV01 TYPE STRING,
NBV02 TYPE STRING,
NBV03 TYPE STRING,
NBV04 TYPE STRING,
NBV05 TYPE STRING,
NBV06 TYPE STRING,
NBV07 TYPE STRING,
NBV08 TYPE STRING,
NBV09 TYPE STRING,
NBV10 TYPE STRING,
NBV11 TYPE STRING,
NBV12 TYPE STRING,
NBV13 TYPE STRING,
TAXEXEMPTIONID TYPE STRING,
TAXEXEMPTIONCODE TYPE STRING,
TAXEXEMPTIONVALUE TYPE STRING,
TAXEXEMPTIONUNITVALUE TYPE STRING,
TAXRATEREDUCNID TYPE STRING,
TAXRATEREDUCNCODE TYPE STRING,
TAXRATE TYPE STRING,
TAXBASEAMT TYPE STRING,
TAXAMTPERIOD TYPE STRING,
TAXAMTDOWNPAYMENT TYPE STRING,
TAXAMTREDUCNID TYPE STRING,
TAXAMTREDUCNCODE TYPE STRING,
TAXAMTREDUCN TYPE STRING,
CADASTRALVALUE TYPE STRING,
OWNERSHIPMONTHS TYPE STRING,
CADASTRALVALUEMONTHS TYPE STRING,
TAXAMTPAIDABROAD TYPE STRING,
REGION TYPE STRING,
ISMOVABLEPROPERTY TYPE STRING,END OF T_EKKO_STR. DATA: WA_FIRUD_PRT_RPITM_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FIRUD_PRT_RPITM_STR-MANDT sy-vline
WA_FIRUD_PRT_RPITM_STR-STATRYRPTGENTITY sy-vline
WA_FIRUD_PRT_RPITM_STR-STATRYRPTCATEGORY sy-vline
WA_FIRUD_PRT_RPITM_STR-STATRYRPTRUNID sy-vline
WA_FIRUD_PRT_RPITM_STR-ITEMID sy-vline
WA_FIRUD_PRT_RPITM_STR-COMPANYCODE sy-vline
WA_FIRUD_PRT_RPITM_STR-MASTERFIXEDASSET sy-vline
WA_FIRUD_PRT_RPITM_STR-FIXEDASSET sy-vline
WA_FIRUD_PRT_RPITM_STR-INTERVALSTART sy-vline
WA_FIRUD_PRT_RPITM_STR-INTERVALEND sy-vline
WA_FIRUD_PRT_RPITM_STR-OKTMO sy-vline
WA_FIRUD_PRT_RPITM_STR-PROPERTYTYPE sy-vline
WA_FIRUD_PRT_RPITM_STR-NBV01 sy-vline
WA_FIRUD_PRT_RPITM_STR-NBV02 sy-vline
WA_FIRUD_PRT_RPITM_STR-NBV03 sy-vline
WA_FIRUD_PRT_RPITM_STR-NBV04 sy-vline
WA_FIRUD_PRT_RPITM_STR-NBV05 sy-vline
WA_FIRUD_PRT_RPITM_STR-NBV06 sy-vline
WA_FIRUD_PRT_RPITM_STR-NBV07 sy-vline
WA_FIRUD_PRT_RPITM_STR-NBV08 sy-vline
WA_FIRUD_PRT_RPITM_STR-NBV09 sy-vline
WA_FIRUD_PRT_RPITM_STR-NBV10 sy-vline
WA_FIRUD_PRT_RPITM_STR-NBV11 sy-vline
WA_FIRUD_PRT_RPITM_STR-NBV12 sy-vline
WA_FIRUD_PRT_RPITM_STR-NBV13 sy-vline
WA_FIRUD_PRT_RPITM_STR-TAXEXEMPTIONID sy-vline
WA_FIRUD_PRT_RPITM_STR-TAXEXEMPTIONCODE sy-vline
WA_FIRUD_PRT_RPITM_STR-TAXEXEMPTIONVALUE sy-vline
WA_FIRUD_PRT_RPITM_STR-TAXEXEMPTIONUNITVALUE sy-vline
WA_FIRUD_PRT_RPITM_STR-TAXRATEREDUCNID sy-vline
WA_FIRUD_PRT_RPITM_STR-TAXRATEREDUCNCODE sy-vline
WA_FIRUD_PRT_RPITM_STR-TAXRATE sy-vline
WA_FIRUD_PRT_RPITM_STR-TAXBASEAMT sy-vline
WA_FIRUD_PRT_RPITM_STR-TAXAMTPERIOD sy-vline
WA_FIRUD_PRT_RPITM_STR-TAXAMTDOWNPAYMENT sy-vline
WA_FIRUD_PRT_RPITM_STR-TAXAMTREDUCNID sy-vline
WA_FIRUD_PRT_RPITM_STR-TAXAMTREDUCNCODE sy-vline
WA_FIRUD_PRT_RPITM_STR-TAXAMTREDUCN sy-vline
WA_FIRUD_PRT_RPITM_STR-CADASTRALVALUE sy-vline
WA_FIRUD_PRT_RPITM_STR-OWNERSHIPMONTHS sy-vline
WA_FIRUD_PRT_RPITM_STR-CADASTRALVALUEMONTHS sy-vline
WA_FIRUD_PRT_RPITM_STR-TAXAMTPAIDABROAD sy-vline
WA_FIRUD_PRT_RPITM_STR-REGION sy-vline
WA_FIRUD_PRT_RPITM_STR-ISMOVABLEPROPERTY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.