ABAP Select data from SAP table FKC_CA_HEADER_OUT into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP FKC_CA_HEADER_OUT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FKC_CA_HEADER_OUT. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the FKC_CA_HEADER_OUT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_FKC_CA_HEADER_OUT TYPE STANDARD TABLE OF FKC_CA_HEADER_OUT, WA_FKC_CA_HEADER_OUT TYPE FKC_CA_HEADER_OUT, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <FKC_CA_HEADER_OUT> TYPE FKC_CA_HEADER_OUT. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_FKC_CA_HEADER_OUT. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM FKC_CA_HEADER_OUT INTO TABLE IT_FKC_CA_HEADER_OUT. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM FKC_CA_HEADER_OUT * INTO TABLE @DATA(IT_FKC_CA_HEADER_OUT2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_FKC_CA_HEADER_OUT INDEX 1 INTO DATA(WA_FKC_CA_HEADER_OUT2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_FKC_CA_HEADER_OUT ASSIGNING <FKC_CA_HEADER_OUT>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<FKC_CA_HEADER_OUT>-CONTROLLER = 1.
<FKC_CA_HEADER_OUT>-IDENTIFICATION = 1.
<FKC_CA_HEADER_OUT>-CONTROLLER = 1.
<FKC_CA_HEADER_OUT>-INTERNAL_ID = 1.
<FKC_CA_HEADER_OUT>-LEGACY_CONTRACT_ACCOUNT_ID = 1.
ENDLOOP. LOOP AT IT_FKC_CA_HEADER_OUT INTO WA_FKC_CA_HEADER_OUT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_FKC_CA_HEADER_OUT-CONTRACT_ACCOUNT_CATEGORY, sy-vline,
WA_FKC_CA_HEADER_OUT-CONTRACT_ACCOUNT_NAME, sy-vline,
WA_FKC_CA_HEADER_OUT-CREATION_DATE, sy-vline,
WA_FKC_CA_HEADER_OUT-CREATED_BY_USER, sy-vline,
WA_FKC_CA_HEADER_OUT-LAST_CHANGE_DATE, sy-vline,
WA_FKC_CA_HEADER_OUT-LAST_CHANGED_BY_USER, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FKC_CA_HEADER_OUT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FKC_CA_HEADER_OUT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FKC_CA_HEADER_OUT INTO WA_FKC_CA_HEADER_OUT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FKC_CA_HEADER_OUT_STR,
CONTROLLER TYPE STRING,
IDENTIFICATION TYPE STRING,
CONTROLLER TYPE STRING,
INTERNAL_ID TYPE STRING,
LEGACY_CONTRACT_ACCOUNT_ID TYPE STRING,
CONTRACT_ACCOUNT_CATEGORY TYPE STRING,
CONTRACT_ACCOUNT_NAME TYPE STRING,
CREATION_DATE TYPE STRING,
CREATED_BY_USER TYPE STRING,
LAST_CHANGE_DATE TYPE STRING,
LAST_CHANGED_BY_USER TYPE STRING,END OF T_EKKO_STR. DATA: WA_FKC_CA_HEADER_OUT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FKC_CA_HEADER_OUT_STR-CONTROLLER sy-vline
WA_FKC_CA_HEADER_OUT_STR-IDENTIFICATION sy-vline
WA_FKC_CA_HEADER_OUT_STR-CONTROLLER sy-vline
WA_FKC_CA_HEADER_OUT_STR-INTERNAL_ID sy-vline
WA_FKC_CA_HEADER_OUT_STR-LEGACY_CONTRACT_ACCOUNT_ID sy-vline
WA_FKC_CA_HEADER_OUT_STR-CONTRACT_ACCOUNT_CATEGORY sy-vline
WA_FKC_CA_HEADER_OUT_STR-CONTRACT_ACCOUNT_NAME sy-vline
WA_FKC_CA_HEADER_OUT_STR-CREATION_DATE sy-vline
WA_FKC_CA_HEADER_OUT_STR-CREATED_BY_USER sy-vline
WA_FKC_CA_HEADER_OUT_STR-LAST_CHANGE_DATE sy-vline
WA_FKC_CA_HEADER_OUT_STR-LAST_CHANGED_BY_USER sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.