ABAP Select data from SAP table FKC_INSTLMNT_PLN_CRT_REQ into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP FKC_INSTLMNT_PLN_CRT_REQ table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FKC_INSTLMNT_PLN_CRT_REQ. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the FKC_INSTLMNT_PLN_CRT_REQ table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_FKC_INSTLMNT_PLN_CRT_REQ TYPE STANDARD TABLE OF FKC_INSTLMNT_PLN_CRT_REQ, WA_FKC_INSTLMNT_PLN_CRT_REQ TYPE FKC_INSTLMNT_PLN_CRT_REQ, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <FKC_INSTLMNT_PLN_CRT_REQ> TYPE FKC_INSTLMNT_PLN_CRT_REQ. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_FKC_INSTLMNT_PLN_CRT_REQ. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM FKC_INSTLMNT_PLN_CRT_REQ INTO TABLE IT_FKC_INSTLMNT_PLN_CRT_REQ. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM FKC_INSTLMNT_PLN_CRT_REQ * INTO TABLE @DATA(IT_FKC_INSTLMNT_PLN_CRT_REQ2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_FKC_INSTLMNT_PLN_CRT_REQ INDEX 1 INTO DATA(WA_FKC_INSTLMNT_PLN_CRT_REQ2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_FKC_INSTLMNT_PLN_CRT_REQ ASSIGNING <FKC_INSTLMNT_PLN_CRT_REQ>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<FKC_INSTLMNT_PLN_CRT_REQ>-CONTROLLER = 1.
<FKC_INSTLMNT_PLN_CRT_REQ>-SENDER_TECHNICAL_ID = 1.
<FKC_INSTLMNT_PLN_CRT_REQ>-INSTALLMENT_PLAN_HEADER = 1.
<FKC_INSTLMNT_PLN_CRT_REQ>-CONTROLLER = 1.
<FKC_INSTLMNT_PLN_CRT_REQ>-CURRENCY = 1.
ENDLOOP. LOOP AT IT_FKC_INSTLMNT_PLN_CRT_REQ INTO WA_FKC_INSTLMNT_PLN_CRT_REQ. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_FKC_INSTLMNT_PLN_CRT_REQ-CAINSTALLMENT_PLAN_CATEGORY, sy-vline,
WA_FKC_INSTLMNT_PLN_CRT_REQ-CAINSTALLMENT_PLAN_TYPE, sy-vline,
WA_FKC_INSTLMNT_PLN_CRT_REQ-CADOCUMENT_TYPE, sy-vline,
WA_FKC_INSTLMNT_PLN_CRT_REQ-CAPOSTING_DATE, sy-vline,
WA_FKC_INSTLMNT_PLN_CRT_REQ-DOCUMENT_DATE, sy-vline,
WA_FKC_INSTLMNT_PLN_CRT_REQ-CAINSTALLMENT_INTERVAL_VALUE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FKC_INSTLMNT_PLN_CRT_REQ you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FKC_INSTLMNT_PLN_CRT_REQ TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FKC_INSTLMNT_PLN_CRT_REQ INTO WA_FKC_INSTLMNT_PLN_CRT_REQ. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FKC_INSTLMNT_PLN_CRT_REQ_STR,
CONTROLLER TYPE STRING,
SENDER_TECHNICAL_ID TYPE STRING,
INSTALLMENT_PLAN_HEADER TYPE STRING,
CONTROLLER TYPE STRING,
CURRENCY TYPE STRING,
CAINSTALLMENT_PLAN_CATEGORY TYPE STRING,
CAINSTALLMENT_PLAN_TYPE TYPE STRING,
CADOCUMENT_TYPE TYPE STRING,
CAPOSTING_DATE TYPE STRING,
DOCUMENT_DATE TYPE STRING,
CAINSTALLMENT_INTERVAL_VALUE TYPE STRING,
CAINSTLMNT_AMOUNT_IN_TRNS_CRCY TYPE STRING,
CONTROLLER TYPE STRING,
CURRENCY_CODE TYPE STRING,
CONTENT TYPE STRING,
CANUMBER_OF_INSTALLMENTS TYPE STRING,
CAINSTALLMENT_PLAN_START_DATE TYPE STRING,
CAINSTLMNT_PLN_INTERVAL_TYPE TYPE STRING,
CAINSTALLMENT_ROUNDING_AMOUNT TYPE STRING,
CONTROLLER TYPE STRING,
CURRENCY_CODE TYPE STRING,
CONTENT TYPE STRING,
CONTRACT_ACCOUNT TYPE STRING,
CONTROLLER TYPE STRING,
INTERNAL_ID TYPE STRING,
LEGACY_CONTRACT_ACCOUNT_ID TYPE STRING,
BUSINESS_PARTNER TYPE STRING,
CONTROLLER TYPE STRING,
INTERNAL_ID TYPE STRING,
LEGACY_BUSINESS_PARTNER_ID TYPE STRING,
CACONTRACT TYPE STRING,
CASUB_APPLICATION TYPE STRING,
CAINTEREST_CALC_START_DATE TYPE STRING,
CADUE_DATE_OF_INTEREST_DOC TYPE STRING,
CAINTEREST_DOCUMENT_TYPE TYPE STRING,
CAINTEREST_CODE TYPE STRING,
CAINSTLMNT_PLN_CHRG_AMNT_INTC TYPE STRING,
CONTROLLER TYPE STRING,
CURRENCY_CODE TYPE STRING,
CONTENT TYPE STRING,
CAINSTLMNT_PLN_RMNG_AMT_DISTR TYPE STRING,
CACHARGE_DOCUMENT_TYPE TYPE STRING,
CAINTRST_AND_CHRGS_DISTRBTD TYPE STRING,
CABUS_PARTNER_DOCUMENT_KEY TYPE STRING,END OF T_EKKO_STR. DATA: WA_FKC_INSTLMNT_PLN_CRT_REQ_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FKC_INSTLMNT_PLN_CRT_REQ_STR-CONTROLLER sy-vline
WA_FKC_INSTLMNT_PLN_CRT_REQ_STR-SENDER_TECHNICAL_ID sy-vline
WA_FKC_INSTLMNT_PLN_CRT_REQ_STR-INSTALLMENT_PLAN_HEADER sy-vline
WA_FKC_INSTLMNT_PLN_CRT_REQ_STR-CONTROLLER sy-vline
WA_FKC_INSTLMNT_PLN_CRT_REQ_STR-CURRENCY sy-vline
WA_FKC_INSTLMNT_PLN_CRT_REQ_STR-CAINSTALLMENT_PLAN_CATEGORY sy-vline
WA_FKC_INSTLMNT_PLN_CRT_REQ_STR-CAINSTALLMENT_PLAN_TYPE sy-vline
WA_FKC_INSTLMNT_PLN_CRT_REQ_STR-CADOCUMENT_TYPE sy-vline
WA_FKC_INSTLMNT_PLN_CRT_REQ_STR-CAPOSTING_DATE sy-vline
WA_FKC_INSTLMNT_PLN_CRT_REQ_STR-DOCUMENT_DATE sy-vline
WA_FKC_INSTLMNT_PLN_CRT_REQ_STR-CAINSTALLMENT_INTERVAL_VALUE sy-vline
WA_FKC_INSTLMNT_PLN_CRT_REQ_STR-CAINSTLMNT_AMOUNT_IN_TRNS_CRCY sy-vline
WA_FKC_INSTLMNT_PLN_CRT_REQ_STR-CONTROLLER sy-vline
WA_FKC_INSTLMNT_PLN_CRT_REQ_STR-CURRENCY_CODE sy-vline
WA_FKC_INSTLMNT_PLN_CRT_REQ_STR-CONTENT sy-vline
WA_FKC_INSTLMNT_PLN_CRT_REQ_STR-CANUMBER_OF_INSTALLMENTS sy-vline
WA_FKC_INSTLMNT_PLN_CRT_REQ_STR-CAINSTALLMENT_PLAN_START_DATE sy-vline
WA_FKC_INSTLMNT_PLN_CRT_REQ_STR-CAINSTLMNT_PLN_INTERVAL_TYPE sy-vline
WA_FKC_INSTLMNT_PLN_CRT_REQ_STR-CAINSTALLMENT_ROUNDING_AMOUNT sy-vline
WA_FKC_INSTLMNT_PLN_CRT_REQ_STR-CONTROLLER sy-vline
WA_FKC_INSTLMNT_PLN_CRT_REQ_STR-CURRENCY_CODE sy-vline
WA_FKC_INSTLMNT_PLN_CRT_REQ_STR-CONTENT sy-vline
WA_FKC_INSTLMNT_PLN_CRT_REQ_STR-CONTRACT_ACCOUNT sy-vline
WA_FKC_INSTLMNT_PLN_CRT_REQ_STR-CONTROLLER sy-vline
WA_FKC_INSTLMNT_PLN_CRT_REQ_STR-INTERNAL_ID sy-vline
WA_FKC_INSTLMNT_PLN_CRT_REQ_STR-LEGACY_CONTRACT_ACCOUNT_ID sy-vline
WA_FKC_INSTLMNT_PLN_CRT_REQ_STR-BUSINESS_PARTNER sy-vline
WA_FKC_INSTLMNT_PLN_CRT_REQ_STR-CONTROLLER sy-vline
WA_FKC_INSTLMNT_PLN_CRT_REQ_STR-INTERNAL_ID sy-vline
WA_FKC_INSTLMNT_PLN_CRT_REQ_STR-LEGACY_BUSINESS_PARTNER_ID sy-vline
WA_FKC_INSTLMNT_PLN_CRT_REQ_STR-CACONTRACT sy-vline
WA_FKC_INSTLMNT_PLN_CRT_REQ_STR-CASUB_APPLICATION sy-vline
WA_FKC_INSTLMNT_PLN_CRT_REQ_STR-CAINTEREST_CALC_START_DATE sy-vline
WA_FKC_INSTLMNT_PLN_CRT_REQ_STR-CADUE_DATE_OF_INTEREST_DOC sy-vline
WA_FKC_INSTLMNT_PLN_CRT_REQ_STR-CAINTEREST_DOCUMENT_TYPE sy-vline
WA_FKC_INSTLMNT_PLN_CRT_REQ_STR-CAINTEREST_CODE sy-vline
WA_FKC_INSTLMNT_PLN_CRT_REQ_STR-CAINSTLMNT_PLN_CHRG_AMNT_INTC sy-vline
WA_FKC_INSTLMNT_PLN_CRT_REQ_STR-CONTROLLER sy-vline
WA_FKC_INSTLMNT_PLN_CRT_REQ_STR-CURRENCY_CODE sy-vline
WA_FKC_INSTLMNT_PLN_CRT_REQ_STR-CONTENT sy-vline
WA_FKC_INSTLMNT_PLN_CRT_REQ_STR-CAINSTLMNT_PLN_RMNG_AMT_DISTR sy-vline
WA_FKC_INSTLMNT_PLN_CRT_REQ_STR-CACHARGE_DOCUMENT_TYPE sy-vline
WA_FKC_INSTLMNT_PLN_CRT_REQ_STR-CAINTRST_AND_CHRGS_DISTRBTD sy-vline
WA_FKC_INSTLMNT_PLN_CRT_REQ_STR-CABUS_PARTNER_DOCUMENT_KEY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.