ABAP Select data from SAP table FKC_MIG_FKKOPC into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP FKC_MIG_FKKOPC table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FKC_MIG_FKKOPC. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the FKC_MIG_FKKOPC table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_FKC_MIG_FKKOPC TYPE STANDARD TABLE OF FKC_MIG_FKKOPC, WA_FKC_MIG_FKKOPC TYPE FKC_MIG_FKKOPC, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <FKC_MIG_FKKOPC> TYPE FKC_MIG_FKKOPC. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_FKC_MIG_FKKOPC. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM FKC_MIG_FKKOPC INTO TABLE IT_FKC_MIG_FKKOPC. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM FKC_MIG_FKKOPC * INTO TABLE @DATA(IT_FKC_MIG_FKKOPC2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_FKC_MIG_FKKOPC INDEX 1 INTO DATA(WA_FKC_MIG_FKKOPC2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_FKC_MIG_FKKOPC ASSIGNING <FKC_MIG_FKKOPC>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<FKC_MIG_FKKOPC>-SENDER_TECHNICAL_ID = 1.
<FKC_MIG_FKKOPC>-OPBEL = 1.
<FKC_MIG_FKKOPC>-PYGRP = 1.
<FKC_MIG_FKKOPC>-XGUID = 1.
<FKC_MIG_FKKOPC>-SRQID = 1.
ENDLOOP. LOOP AT IT_FKC_MIG_FKKOPC INTO WA_FKC_MIG_FKKOPC. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_FKC_MIG_FKKOPC-CCINS, sy-vline,
WA_FKC_MIG_FKKOPC-CCNUM, sy-vline,
WA_FKC_MIG_FKKOPC-CCFOL, sy-vline,
WA_FKC_MIG_FKKOPC-DATAB, sy-vline,
WA_FKC_MIG_FKKOPC-DATBI, sy-vline,
WA_FKC_MIG_FKKOPC-CCNAME, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FKC_MIG_FKKOPC you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FKC_MIG_FKKOPC TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FKC_MIG_FKKOPC INTO WA_FKC_MIG_FKKOPC. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field OPBEL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FKC_MIG_FKKOPC-OPBEL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FKC_MIG_FKKOPC-OPBEL.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FKC_MIG_FKKOPC_STR,
SENDER_TECHNICAL_ID TYPE STRING,
OPBEL TYPE STRING,
PYGRP TYPE STRING,
XGUID TYPE STRING,
SRQID TYPE STRING,
CCINS TYPE STRING,
CCNUM TYPE STRING,
CCFOL TYPE STRING,
DATAB TYPE STRING,
DATBI TYPE STRING,
CCNAME TYPE STRING,
AUNUM TYPE STRING,
AUTRA TYPE STRING,
AUDAT TYPE STRING,
AUTIM TYPE STRING,
AUART TYPE STRING,
AUTWR TYPE STRING,
CCWAE TYPE STRING,
MERCH TYPE STRING,
EXPDT TYPE STRING,
EXPTM TYPE STRING,
EXTMP TYPE STRING,
AUTMP TYPE STRING,
AUCID TYPE STRING,
AVREF TYPE STRING,
DP_AUTH_REL_ID TYPE STRING,
DP_FRAUD_RISK TYPE STRING,
CVVAL TYPE STRING,
CVVCT TYPE STRING,
CVVST TYPE STRING,
CGUID TYPE STRING,
ENCTP TYPE STRING,END OF T_EKKO_STR. DATA: WA_FKC_MIG_FKKOPC_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FKC_MIG_FKKOPC_STR-SENDER_TECHNICAL_ID sy-vline
WA_FKC_MIG_FKKOPC_STR-OPBEL sy-vline
WA_FKC_MIG_FKKOPC_STR-PYGRP sy-vline
WA_FKC_MIG_FKKOPC_STR-XGUID sy-vline
WA_FKC_MIG_FKKOPC_STR-SRQID sy-vline
WA_FKC_MIG_FKKOPC_STR-CCINS sy-vline
WA_FKC_MIG_FKKOPC_STR-CCNUM sy-vline
WA_FKC_MIG_FKKOPC_STR-CCFOL sy-vline
WA_FKC_MIG_FKKOPC_STR-DATAB sy-vline
WA_FKC_MIG_FKKOPC_STR-DATBI sy-vline
WA_FKC_MIG_FKKOPC_STR-CCNAME sy-vline
WA_FKC_MIG_FKKOPC_STR-AUNUM sy-vline
WA_FKC_MIG_FKKOPC_STR-AUTRA sy-vline
WA_FKC_MIG_FKKOPC_STR-AUDAT sy-vline
WA_FKC_MIG_FKKOPC_STR-AUTIM sy-vline
WA_FKC_MIG_FKKOPC_STR-AUART sy-vline
WA_FKC_MIG_FKKOPC_STR-AUTWR sy-vline
WA_FKC_MIG_FKKOPC_STR-CCWAE sy-vline
WA_FKC_MIG_FKKOPC_STR-MERCH sy-vline
WA_FKC_MIG_FKKOPC_STR-EXPDT sy-vline
WA_FKC_MIG_FKKOPC_STR-EXPTM sy-vline
WA_FKC_MIG_FKKOPC_STR-EXTMP sy-vline
WA_FKC_MIG_FKKOPC_STR-AUTMP sy-vline
WA_FKC_MIG_FKKOPC_STR-AUCID sy-vline
WA_FKC_MIG_FKKOPC_STR-AVREF sy-vline
WA_FKC_MIG_FKKOPC_STR-DP_AUTH_REL_ID sy-vline
WA_FKC_MIG_FKKOPC_STR-DP_FRAUD_RISK sy-vline
WA_FKC_MIG_FKKOPC_STR-CVVAL sy-vline
WA_FKC_MIG_FKKOPC_STR-CVVCT sy-vline
WA_FKC_MIG_FKKOPC_STR-CVVST sy-vline
WA_FKC_MIG_FKKOPC_STR-CGUID sy-vline
WA_FKC_MIG_FKKOPC_STR-ENCTP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.