ABAP Select data from SAP table FKKBIXCIT0_FIX into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FKKBIXCIT0_FIX table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FKKBIXCIT0_FIX. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FKKBIXCIT0_FIX table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FKKBIXCIT0_FIX TYPE STANDARD TABLE OF FKKBIXCIT0_FIX,
      WA_FKKBIXCIT0_FIX TYPE FKKBIXCIT0_FIX,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FKKBIXCIT0_FIX> TYPE FKKBIXCIT0_FIX.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FKKBIXCIT0_FIX.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FKKBIXCIT0_FIX
  INTO TABLE IT_FKKBIXCIT0_FIX.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FKKBIXCIT0_FIX
*  INTO TABLE @DATA(IT_FKKBIXCIT0_FIX2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FKKBIXCIT0_FIX INDEX 1 INTO DATA(WA_FKKBIXCIT0_FIX2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FKKBIXCIT0_FIX ASSIGNING <FKKBIXCIT0_FIX>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FKKBIXCIT0_FIX>-MANDT = 1.
<FKKBIXCIT0_FIX>-CITIDTYPE = 1.
<FKKBIXCIT0_FIX>-CITID = 1.
<FKKBIXCIT0_FIX>-CITUUID = 1.
<FKKBIXCIT0_FIX>-CITSTATUS = 1.
ENDLOOP.

LOOP AT IT_FKKBIXCIT0_FIX INTO WA_FKKBIXCIT0_FIX.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FKKBIXCIT0_FIX-CITCAT, sy-vline,
WA_FKKBIXCIT0_FIX-CITCRDATE, sy-vline,
WA_FKKBIXCIT0_FIX-CITCRTIME, sy-vline,
WA_FKKBIXCIT0_FIX-CITCRMODE, sy-vline,
WA_FKKBIXCIT0_FIX-CHHIST, sy-vline,
WA_FKKBIXCIT0_FIX-RATINGCNT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FKKBIXCIT0_FIX you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FKKBIXCIT0_FIX TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FKKBIXCIT0_FIX INTO WA_FKKBIXCIT0_FIX. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field SRCTAID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FKKBIXCIT0_FIX-SRCTAID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FKKBIXCIT0_FIX-SRCTAID.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FKKBIXCIT0_FIX_STR,
MANDT TYPE STRING,
CITIDTYPE TYPE STRING,
CITID TYPE STRING,
CITUUID TYPE STRING,
CITSTATUS TYPE STRING,
CITCAT TYPE STRING,
CITCRDATE TYPE STRING,
CITCRTIME TYPE STRING,
CITCRMODE TYPE STRING,
CHHIST TYPE STRING,
RATINGCNT TYPE STRING,
CITPACKUUID TYPE STRING,
CITPACKCNO TYPE STRING,
CITPACKNUM TYPE STRING,
CITDATAPACKID TYPE STRING,
KEYPP TYPE STRING,
EXCDATE TYPE STRING,
EXCHIST TYPE STRING,
EXCREASON TYPE STRING,
EXCTIME TYPE STRING,
EXCUSNAM TYPE STRING,
CITREVERSED TYPE STRING,
SRCTAID TYPE STRING,
SRCTATYPE TYPE STRING,
RATINGDATE TYPE STRING,END OF T_EKKO_STR. DATA: WA_FKKBIXCIT0_FIX_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FKKBIXCIT0_FIX_STR-MANDT sy-vline
WA_FKKBIXCIT0_FIX_STR-CITIDTYPE sy-vline
WA_FKKBIXCIT0_FIX_STR-CITID sy-vline
WA_FKKBIXCIT0_FIX_STR-CITUUID sy-vline
WA_FKKBIXCIT0_FIX_STR-CITSTATUS sy-vline
WA_FKKBIXCIT0_FIX_STR-CITCAT sy-vline
WA_FKKBIXCIT0_FIX_STR-CITCRDATE sy-vline
WA_FKKBIXCIT0_FIX_STR-CITCRTIME sy-vline
WA_FKKBIXCIT0_FIX_STR-CITCRMODE sy-vline
WA_FKKBIXCIT0_FIX_STR-CHHIST sy-vline
WA_FKKBIXCIT0_FIX_STR-RATINGCNT sy-vline
WA_FKKBIXCIT0_FIX_STR-CITPACKUUID sy-vline
WA_FKKBIXCIT0_FIX_STR-CITPACKCNO sy-vline
WA_FKKBIXCIT0_FIX_STR-CITPACKNUM sy-vline
WA_FKKBIXCIT0_FIX_STR-CITDATAPACKID sy-vline
WA_FKKBIXCIT0_FIX_STR-KEYPP sy-vline
WA_FKKBIXCIT0_FIX_STR-EXCDATE sy-vline
WA_FKKBIXCIT0_FIX_STR-EXCHIST sy-vline
WA_FKKBIXCIT0_FIX_STR-EXCREASON sy-vline
WA_FKKBIXCIT0_FIX_STR-EXCTIME sy-vline
WA_FKKBIXCIT0_FIX_STR-EXCUSNAM sy-vline
WA_FKKBIXCIT0_FIX_STR-CITREVERSED sy-vline
WA_FKKBIXCIT0_FIX_STR-SRCTAID sy-vline
WA_FKKBIXCIT0_FIX_STR-SRCTATYPE sy-vline
WA_FKKBIXCIT0_FIX_STR-RATINGDATE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.