ABAP Select data from SAP table FKKBIXCIT_SEL into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP FKKBIXCIT_SEL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FKKBIXCIT_SEL. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the FKKBIXCIT_SEL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_FKKBIXCIT_SEL TYPE STANDARD TABLE OF FKKBIXCIT_SEL, WA_FKKBIXCIT_SEL TYPE FKKBIXCIT_SEL, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <FKKBIXCIT_SEL> TYPE FKKBIXCIT_SEL. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_FKKBIXCIT_SEL. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM FKKBIXCIT_SEL INTO TABLE IT_FKKBIXCIT_SEL. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM FKKBIXCIT_SEL * INTO TABLE @DATA(IT_FKKBIXCIT_SEL2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_FKKBIXCIT_SEL INDEX 1 INTO DATA(WA_FKKBIXCIT_SEL2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_FKKBIXCIT_SEL ASSIGNING <FKKBIXCIT_SEL>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<FKKBIXCIT_SEL>-ACCESS_USERID_RTAB = 1.
<FKKBIXCIT_SEL>-ACCESS_SERVICEID_RTAB = 1.
<FKKBIXCIT_SEL>-CONSUMDATE_RTAB = 1.
<FKKBIXCIT_SEL>-CITDATE_RTAB = 1.
<FKKBIXCIT_SEL>-CITCRDATE_RTAB = 1.
ENDLOOP. LOOP AT IT_FKKBIXCIT_SEL INTO WA_FKKBIXCIT_SEL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_FKKBIXCIT_SEL-RATINGDATE_RTAB, sy-vline,
WA_FKKBIXCIT_SEL-KEYPP_RTAB, sy-vline,
WA_FKKBIXCIT_SEL-GPART_RTAB, sy-vline,
WA_FKKBIXCIT_SEL-VKONT_RTAB, sy-vline,
WA_FKKBIXCIT_SEL-VTREF_RTAB, sy-vline,
WA_FKKBIXCIT_SEL-SUBAP_RTAB, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FKKBIXCIT_SEL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FKKBIXCIT_SEL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FKKBIXCIT_SEL INTO WA_FKKBIXCIT_SEL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FKKBIXCIT_SEL_STR,
ACCESS_USERID_RTAB TYPE STRING,
ACCESS_SERVICEID_RTAB TYPE STRING,
CONSUMDATE_RTAB TYPE STRING,
CITDATE_RTAB TYPE STRING,
CITCRDATE_RTAB TYPE STRING,
RATINGDATE_RTAB TYPE STRING,
KEYPP_RTAB TYPE STRING,
GPART_RTAB TYPE STRING,
VKONT_RTAB TYPE STRING,
VTREF_RTAB TYPE STRING,
SUBAP_RTAB TYPE STRING,
CITSTATUS_RTAB TYPE STRING,
CITCAT_RTAB TYPE STRING,
CITID_RTAB TYPE STRING,
CITIDTYPE_RTAB TYPE STRING,
CITDATAPACKID_RTAB TYPE STRING,
SRCTATYPE_RTAB TYPE STRING,
SRCTAID_RTAB TYPE STRING,
SRCTASUBID_RTAB TYPE STRING,
CITREVERSED_RTAB TYPE STRING,
RATINGREVERSED_RTAB TYPE STRING,
RATE_FIRST_RTAB TYPE STRING,
FURTHER_SEL_TAB TYPE STRING,
BIXCIT_DBTAB_TAB TYPE STRING,
RECORDS TYPE STRING,
MAXREC TYPE STRING,END OF T_EKKO_STR. DATA: WA_FKKBIXCIT_SEL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FKKBIXCIT_SEL_STR-ACCESS_USERID_RTAB sy-vline
WA_FKKBIXCIT_SEL_STR-ACCESS_SERVICEID_RTAB sy-vline
WA_FKKBIXCIT_SEL_STR-CONSUMDATE_RTAB sy-vline
WA_FKKBIXCIT_SEL_STR-CITDATE_RTAB sy-vline
WA_FKKBIXCIT_SEL_STR-CITCRDATE_RTAB sy-vline
WA_FKKBIXCIT_SEL_STR-RATINGDATE_RTAB sy-vline
WA_FKKBIXCIT_SEL_STR-KEYPP_RTAB sy-vline
WA_FKKBIXCIT_SEL_STR-GPART_RTAB sy-vline
WA_FKKBIXCIT_SEL_STR-VKONT_RTAB sy-vline
WA_FKKBIXCIT_SEL_STR-VTREF_RTAB sy-vline
WA_FKKBIXCIT_SEL_STR-SUBAP_RTAB sy-vline
WA_FKKBIXCIT_SEL_STR-CITSTATUS_RTAB sy-vline
WA_FKKBIXCIT_SEL_STR-CITCAT_RTAB sy-vline
WA_FKKBIXCIT_SEL_STR-CITID_RTAB sy-vline
WA_FKKBIXCIT_SEL_STR-CITIDTYPE_RTAB sy-vline
WA_FKKBIXCIT_SEL_STR-CITDATAPACKID_RTAB sy-vline
WA_FKKBIXCIT_SEL_STR-SRCTATYPE_RTAB sy-vline
WA_FKKBIXCIT_SEL_STR-SRCTAID_RTAB sy-vline
WA_FKKBIXCIT_SEL_STR-SRCTASUBID_RTAB sy-vline
WA_FKKBIXCIT_SEL_STR-CITREVERSED_RTAB sy-vline
WA_FKKBIXCIT_SEL_STR-RATINGREVERSED_RTAB sy-vline
WA_FKKBIXCIT_SEL_STR-RATE_FIRST_RTAB sy-vline
WA_FKKBIXCIT_SEL_STR-FURTHER_SEL_TAB sy-vline
WA_FKKBIXCIT_SEL_STR-BIXCIT_DBTAB_TAB sy-vline
WA_FKKBIXCIT_SEL_STR-RECORDS sy-vline
WA_FKKBIXCIT_SEL_STR-MAXREC sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.