ABAP Select data from SAP table FKKCRCL_DISPL into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FKKCRCL_DISPL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FKKCRCL_DISPL. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FKKCRCL_DISPL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FKKCRCL_DISPL TYPE STANDARD TABLE OF FKKCRCL_DISPL,
      WA_FKKCRCL_DISPL TYPE FKKCRCL_DISPL,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FKKCRCL_DISPL> TYPE FKKCRCL_DISPL.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FKKCRCL_DISPL.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FKKCRCL_DISPL
  INTO TABLE IT_FKKCRCL_DISPL.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FKKCRCL_DISPL
*  INTO TABLE @DATA(IT_FKKCRCL_DISPL2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FKKCRCL_DISPL INDEX 1 INTO DATA(WA_FKKCRCL_DISPL2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FKKCRCL_DISPL ASSIGNING <FKKCRCL_DISPL>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FKKCRCL_DISPL>-MARK = 1.
<FKKCRCL_DISPL>-ICON = 1.
<FKKCRCL_DISPL>-WORKICON = 1.
<FKKCRCL_DISPL>-STATE_TXT = 1.
<FKKCRCL_DISPL>-WORKSTATE_TXT = 1.
ENDLOOP.

LOOP AT IT_FKKCRCL_DISPL INTO WA_FKKCRCL_DISPL.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FKKCRCL_DISPL-ACTION_TXT, sy-vline,
WA_FKKCRCL_DISPL-TILE_ID_TXT, sy-vline,
WA_FKKCRCL_DISPL-GPART_TXT, sy-vline,
WA_FKKCRCL_DISPL-USER_TXT, sy-vline,
WA_FKKCRCL_DISPL-HERKF, sy-vline,
WA_FKKCRCL_DISPL-ORG1T, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FKKCRCL_DISPL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FKKCRCL_DISPL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FKKCRCL_DISPL INTO WA_FKKCRCL_DISPL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field ZTNUM CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FKKCRCL_DISPL-ZTNUM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FKKCRCL_DISPL-ZTNUM.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FKKCRCL_DISPL_STR,
MARK TYPE STRING,
ICON TYPE STRING,
WORKICON TYPE STRING,
STATE_TXT TYPE STRING,
WORKSTATE_TXT TYPE STRING,
ACTION_TXT TYPE STRING,
TILE_ID_TXT TYPE STRING,
GPART_TXT TYPE STRING,
USER_TXT TYPE STRING,
HERKF TYPE STRING,
ORG1T TYPE STRING,
ORG1R TYPE STRING,
HBKID TYPE STRING,
HKTID TYPE STRING,
ZTART TYPE STRING,
ZTNUM TYPE STRING,
ERDAT TYPE STRING,
ERTIM TYPE STRING,
DOC1T TYPE STRING,
DOC1R TYPE STRING,
DOC2T TYPE STRING,
DOC2R TYPE STRING,
AUBET TYPE STRING,
AUWAE TYPE STRING,
EIBET TYPE STRING,
EIWAE TYPE STRING,
AUGRD TYPE STRING,
XFINI TYPE STRING,
UNAME TYPE STRING,
AEDAT TYPE STRING,
AETIM TYPE STRING,
COMMT TYPE STRING,
XCHILD TYPE STRING,
STATE TYPE STRING,
LOCK_USER TYPE STRING,
LOCK_LIMIT TYPE STRING,
WORKSTATE TYPE STRING,
RESUBMIT_DATE TYPE STRING,
WF_COUNT TYPE STRING,END OF T_EKKO_STR. DATA: WA_FKKCRCL_DISPL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FKKCRCL_DISPL_STR-MARK sy-vline
WA_FKKCRCL_DISPL_STR-ICON sy-vline
WA_FKKCRCL_DISPL_STR-WORKICON sy-vline
WA_FKKCRCL_DISPL_STR-STATE_TXT sy-vline
WA_FKKCRCL_DISPL_STR-WORKSTATE_TXT sy-vline
WA_FKKCRCL_DISPL_STR-ACTION_TXT sy-vline
WA_FKKCRCL_DISPL_STR-TILE_ID_TXT sy-vline
WA_FKKCRCL_DISPL_STR-GPART_TXT sy-vline
WA_FKKCRCL_DISPL_STR-USER_TXT sy-vline
WA_FKKCRCL_DISPL_STR-HERKF sy-vline
WA_FKKCRCL_DISPL_STR-ORG1T sy-vline
WA_FKKCRCL_DISPL_STR-ORG1R sy-vline
WA_FKKCRCL_DISPL_STR-HBKID sy-vline
WA_FKKCRCL_DISPL_STR-HKTID sy-vline
WA_FKKCRCL_DISPL_STR-ZTART sy-vline
WA_FKKCRCL_DISPL_STR-ZTNUM sy-vline
WA_FKKCRCL_DISPL_STR-ERDAT sy-vline
WA_FKKCRCL_DISPL_STR-ERTIM sy-vline
WA_FKKCRCL_DISPL_STR-DOC1T sy-vline
WA_FKKCRCL_DISPL_STR-DOC1R sy-vline
WA_FKKCRCL_DISPL_STR-DOC2T sy-vline
WA_FKKCRCL_DISPL_STR-DOC2R sy-vline
WA_FKKCRCL_DISPL_STR-AUBET sy-vline
WA_FKKCRCL_DISPL_STR-AUWAE sy-vline
WA_FKKCRCL_DISPL_STR-EIBET sy-vline
WA_FKKCRCL_DISPL_STR-EIWAE sy-vline
WA_FKKCRCL_DISPL_STR-AUGRD sy-vline
WA_FKKCRCL_DISPL_STR-XFINI sy-vline
WA_FKKCRCL_DISPL_STR-UNAME sy-vline
WA_FKKCRCL_DISPL_STR-AEDAT sy-vline
WA_FKKCRCL_DISPL_STR-AETIM sy-vline
WA_FKKCRCL_DISPL_STR-COMMT sy-vline
WA_FKKCRCL_DISPL_STR-XCHILD sy-vline
WA_FKKCRCL_DISPL_STR-STATE sy-vline
WA_FKKCRCL_DISPL_STR-LOCK_USER sy-vline
WA_FKKCRCL_DISPL_STR-LOCK_LIMIT sy-vline
WA_FKKCRCL_DISPL_STR-WORKSTATE sy-vline
WA_FKKCRCL_DISPL_STR-RESUBMIT_DATE sy-vline
WA_FKKCRCL_DISPL_STR-WF_COUNT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.