ABAP Select data from SAP table FKKRW_ACCITA into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP FKKRW_ACCITA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FKKRW_ACCITA. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the FKKRW_ACCITA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_FKKRW_ACCITA TYPE STANDARD TABLE OF FKKRW_ACCITA, WA_FKKRW_ACCITA TYPE FKKRW_ACCITA, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <FKKRW_ACCITA> TYPE FKKRW_ACCITA. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_FKKRW_ACCITA. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM FKKRW_ACCITA INTO TABLE IT_FKKRW_ACCITA. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM FKKRW_ACCITA * INTO TABLE @DATA(IT_FKKRW_ACCITA2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_FKKRW_ACCITA INDEX 1 INTO DATA(WA_FKKRW_ACCITA2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_FKKRW_ACCITA ASSIGNING <FKKRW_ACCITA>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<FKKRW_ACCITA>-KONTT = 1.
<FKKRW_ACCITA>-KONTL = 1.
<FKKRW_ACCITA>-ACTV_ACCOUNT = 1.
<FKKRW_ACCITA>-BLART_FKK = 1.
<FKKRW_ACCITA>-VKONT = 1.
ENDLOOP. LOOP AT IT_FKKRW_ACCITA INTO WA_FKKRW_ACCITA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_FKKRW_ACCITA-VTREF, sy-vline,
WA_FKKRW_ACCITA-SUBAP, sy-vline,
WA_FKKRW_ACCITA-VTRE2, sy-vline,
WA_FKKRW_ACCITA-FIKEY, sy-vline,
WA_FKKRW_ACCITA-HVORG, sy-vline,
WA_FKKRW_ACCITA-TVORG, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FKKRW_ACCITA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FKKRW_ACCITA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FKKRW_ACCITA INTO WA_FKKRW_ACCITA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field VKONT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FKKRW_ACCITA-VKONT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FKKRW_ACCITA-VKONT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field VTREF CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FKKRW_ACCITA-VTREF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FKKRW_ACCITA-VTREF.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field VTRE2 CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FKKRW_ACCITA-VTRE2 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FKKRW_ACCITA-VTRE2.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field NRZAS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FKKRW_ACCITA-NRZAS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FKKRW_ACCITA-NRZAS.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field OPBEL CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FKKRW_ACCITA-OPBEL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FKKRW_ACCITA-OPBEL.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field OPBEL_DP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FKKRW_ACCITA-OPBEL_DP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FKKRW_ACCITA-OPBEL_DP.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FKKRW_ACCITA_STR,
KONTT TYPE STRING,
KONTL TYPE STRING,
ACTV_ACCOUNT TYPE STRING,
BLART_FKK TYPE STRING,
VKONT TYPE STRING,
VTREF TYPE STRING,
SUBAP TYPE STRING,
VTRE2 TYPE STRING,
FIKEY TYPE STRING,
HVORG TYPE STRING,
TVORG TYPE STRING,
XMBEL TYPE STRING,
TXEXK TYPE STRING,
J_1AFITP TYPE STRING,
COUNC TYPE STRING,
NRZAS TYPE STRING,
RFZAS TYPE STRING,
OPBEL TYPE STRING,
REFERENCE_NO TYPE STRING,
CASE_GUID TYPE STRING,
PRTID TYPE STRING,
POSNR_FM TYPE STRING,
AASTA TYPE STRING,
PSGRP TYPE STRING,
OPBEL_DP TYPE STRING,
OPUPK_DP TYPE STRING,
OPUPZ_DP TYPE STRING,
FPLNR TYPE STRING,
FPLTR TYPE STRING,
FAREG TYPE STRING,
STAKZ TYPE STRING,
XANZA TYPE STRING,
XHRAT TYPE STRING,
XSETDP TYPE STRING,
XTRNDP TYPE STRING,
RWIN_DUMMY TYPE STRING,END OF T_EKKO_STR. DATA: WA_FKKRW_ACCITA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FKKRW_ACCITA_STR-KONTT sy-vline
WA_FKKRW_ACCITA_STR-KONTL sy-vline
WA_FKKRW_ACCITA_STR-ACTV_ACCOUNT sy-vline
WA_FKKRW_ACCITA_STR-BLART_FKK sy-vline
WA_FKKRW_ACCITA_STR-VKONT sy-vline
WA_FKKRW_ACCITA_STR-VTREF sy-vline
WA_FKKRW_ACCITA_STR-SUBAP sy-vline
WA_FKKRW_ACCITA_STR-VTRE2 sy-vline
WA_FKKRW_ACCITA_STR-FIKEY sy-vline
WA_FKKRW_ACCITA_STR-HVORG sy-vline
WA_FKKRW_ACCITA_STR-TVORG sy-vline
WA_FKKRW_ACCITA_STR-XMBEL sy-vline
WA_FKKRW_ACCITA_STR-TXEXK sy-vline
WA_FKKRW_ACCITA_STR-J_1AFITP sy-vline
WA_FKKRW_ACCITA_STR-COUNC sy-vline
WA_FKKRW_ACCITA_STR-NRZAS sy-vline
WA_FKKRW_ACCITA_STR-RFZAS sy-vline
WA_FKKRW_ACCITA_STR-OPBEL sy-vline
WA_FKKRW_ACCITA_STR-REFERENCE_NO sy-vline
WA_FKKRW_ACCITA_STR-CASE_GUID sy-vline
WA_FKKRW_ACCITA_STR-PRTID sy-vline
WA_FKKRW_ACCITA_STR-POSNR_FM sy-vline
WA_FKKRW_ACCITA_STR-AASTA sy-vline
WA_FKKRW_ACCITA_STR-PSGRP sy-vline
WA_FKKRW_ACCITA_STR-OPBEL_DP sy-vline
WA_FKKRW_ACCITA_STR-OPUPK_DP sy-vline
WA_FKKRW_ACCITA_STR-OPUPZ_DP sy-vline
WA_FKKRW_ACCITA_STR-FPLNR sy-vline
WA_FKKRW_ACCITA_STR-FPLTR sy-vline
WA_FKKRW_ACCITA_STR-FAREG sy-vline
WA_FKKRW_ACCITA_STR-STAKZ sy-vline
WA_FKKRW_ACCITA_STR-XANZA sy-vline
WA_FKKRW_ACCITA_STR-XHRAT sy-vline
WA_FKKRW_ACCITA_STR-XSETDP sy-vline
WA_FKKRW_ACCITA_STR-XTRNDP sy-vline
WA_FKKRW_ACCITA_STR-RWIN_DUMMY sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.