ABAP Select data from SAP table FMADB_DEFAULT_AA into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP FMADB_DEFAULT_AA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FMADB_DEFAULT_AA. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the FMADB_DEFAULT_AA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_FMADB_DEFAULT_AA TYPE STANDARD TABLE OF FMADB_DEFAULT_AA, WA_FMADB_DEFAULT_AA TYPE FMADB_DEFAULT_AA, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <FMADB_DEFAULT_AA> TYPE FMADB_DEFAULT_AA. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_FMADB_DEFAULT_AA. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM FMADB_DEFAULT_AA INTO TABLE IT_FMADB_DEFAULT_AA. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM FMADB_DEFAULT_AA * INTO TABLE @DATA(IT_FMADB_DEFAULT_AA2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_FMADB_DEFAULT_AA INDEX 1 INTO DATA(WA_FMADB_DEFAULT_AA2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_FMADB_DEFAULT_AA ASSIGNING <FMADB_DEFAULT_AA>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<FMADB_DEFAULT_AA>-MANDT = 1.
<FMADB_DEFAULT_AA>-ADB_ID = 1.
<FMADB_DEFAULT_AA>-ADB_POOL = 1.
<FMADB_DEFAULT_AA>-FIPOS = 1.
<FMADB_DEFAULT_AA>-FISTL = 1.
ENDLOOP. LOOP AT IT_FMADB_DEFAULT_AA INTO WA_FMADB_DEFAULT_AA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_FMADB_DEFAULT_AA-FONDS, sy-vline,
WA_FMADB_DEFAULT_AA-BUDGET, sy-vline,
WA_FMADB_DEFAULT_AA-FAREA, sy-vline,
WA_FMADB_DEFAULT_AA-MEASURE, sy-vline,
WA_FMADB_DEFAULT_AA-GRANT_NBR, sy-vline,
WA_FMADB_DEFAULT_AA-SEGMENT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FMADB_DEFAULT_AA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FMADB_DEFAULT_AA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FMADB_DEFAULT_AA INTO WA_FMADB_DEFAULT_AA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit FMCIS, internal->external for field FIPOS CALL FUNCTION 'CONVERSION_EXIT_FMCIS_OUTPUT' EXPORTING input = WA_FMADB_DEFAULT_AA-FIPOS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FMADB_DEFAULT_AA-FIPOS.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field GRANT_NBR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FMADB_DEFAULT_AA-GRANT_NBR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FMADB_DEFAULT_AA-GRANT_NBR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field SEGMENT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FMADB_DEFAULT_AA-SEGMENT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FMADB_DEFAULT_AA-SEGMENT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field PRCTR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FMADB_DEFAULT_AA-PRCTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FMADB_DEFAULT_AA-PRCTR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FMADB_DEFAULT_AA_STR,
MANDT TYPE STRING,
ADB_ID TYPE STRING,
ADB_POOL TYPE STRING,
FIPOS TYPE STRING,
FISTL TYPE STRING,
FONDS TYPE STRING,
BUDGET TYPE STRING,
FAREA TYPE STRING,
MEASURE TYPE STRING,
GRANT_NBR TYPE STRING,
SEGMENT TYPE STRING,
GSBER TYPE STRING,
PRCTR TYPE STRING,END OF T_EKKO_STR. DATA: WA_FMADB_DEFAULT_AA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FMADB_DEFAULT_AA_STR-MANDT sy-vline
WA_FMADB_DEFAULT_AA_STR-ADB_ID sy-vline
WA_FMADB_DEFAULT_AA_STR-ADB_POOL sy-vline
WA_FMADB_DEFAULT_AA_STR-FIPOS sy-vline
WA_FMADB_DEFAULT_AA_STR-FISTL sy-vline
WA_FMADB_DEFAULT_AA_STR-FONDS sy-vline
WA_FMADB_DEFAULT_AA_STR-BUDGET sy-vline
WA_FMADB_DEFAULT_AA_STR-FAREA sy-vline
WA_FMADB_DEFAULT_AA_STR-MEASURE sy-vline
WA_FMADB_DEFAULT_AA_STR-GRANT_NBR sy-vline
WA_FMADB_DEFAULT_AA_STR-SEGMENT sy-vline
WA_FMADB_DEFAULT_AA_STR-GSBER sy-vline
WA_FMADB_DEFAULT_AA_STR-PRCTR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.