ABAP Select data from SAP table FMBS_S_PO_LOCK into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP FMBS_S_PO_LOCK table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FMBS_S_PO_LOCK. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the FMBS_S_PO_LOCK table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_FMBS_S_PO_LOCK TYPE STANDARD TABLE OF FMBS_S_PO_LOCK, WA_FMBS_S_PO_LOCK TYPE FMBS_S_PO_LOCK, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <FMBS_S_PO_LOCK> TYPE FMBS_S_PO_LOCK. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_FMBS_S_PO_LOCK. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM FMBS_S_PO_LOCK INTO TABLE IT_FMBS_S_PO_LOCK. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM FMBS_S_PO_LOCK * INTO TABLE @DATA(IT_FMBS_S_PO_LOCK2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_FMBS_S_PO_LOCK INDEX 1 INTO DATA(WA_FMBS_S_PO_LOCK2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_FMBS_S_PO_LOCK ASSIGNING <FMBS_S_PO_LOCK>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<FMBS_S_PO_LOCK>-CLIENT = 1.
<FMBS_S_PO_LOCK>-FM_AREA = 1.
<FMBS_S_PO_LOCK>-FISCYEAR = 1.
<FMBS_S_PO_LOCK>-PLDNR = 1.
<FMBS_S_PO_LOCK>-FUND = 1.
ENDLOOP. LOOP AT IT_FMBS_S_PO_LOCK INTO WA_FMBS_S_PO_LOCK. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_FMBS_S_PO_LOCK-FUNDSCTR, sy-vline,
WA_FMBS_S_PO_LOCK-CMMTITEM, sy-vline,
WA_FMBS_S_PO_LOCK-FUNCAREA, sy-vline,
WA_FMBS_S_PO_LOCK-GRANT_NBR, sy-vline,
WA_FMBS_S_PO_LOCK-MEASURE, sy-vline,
WA_FMBS_S_PO_LOCK-USERDIM, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FMBS_S_PO_LOCK you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FMBS_S_PO_LOCK TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FMBS_S_PO_LOCK INTO WA_FMBS_S_PO_LOCK. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit GJAHR, internal->external for field FISCYEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_FMBS_S_PO_LOCK-FISCYEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FMBS_S_PO_LOCK-FISCYEAR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field PLDNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FMBS_S_PO_LOCK-PLDNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FMBS_S_PO_LOCK-PLDNR.
WRITE:/ 'New Value:', ld_input.
*Conversion exit FMCIL, internal->external for field CMMTITEM CALL FUNCTION 'CONVERSION_EXIT_FMCIL_OUTPUT' EXPORTING input = WA_FMBS_S_PO_LOCK-CMMTITEM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FMBS_S_PO_LOCK-CMMTITEM.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field GRANT_NBR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FMBS_S_PO_LOCK-GRANT_NBR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FMBS_S_PO_LOCK-GRANT_NBR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FMBS_S_PO_LOCK_STR,
CLIENT TYPE STRING,
FM_AREA TYPE STRING,
FISCYEAR TYPE STRING,
PLDNR TYPE STRING,
FUND TYPE STRING,
FUNDSCTR TYPE STRING,
CMMTITEM TYPE STRING,
FUNCAREA TYPE STRING,
GRANT_NBR TYPE STRING,
MEASURE TYPE STRING,
USERDIM TYPE STRING,
BUDGET_PD TYPE STRING,END OF T_EKKO_STR. DATA: WA_FMBS_S_PO_LOCK_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FMBS_S_PO_LOCK_STR-CLIENT sy-vline
WA_FMBS_S_PO_LOCK_STR-FM_AREA sy-vline
WA_FMBS_S_PO_LOCK_STR-FISCYEAR sy-vline
WA_FMBS_S_PO_LOCK_STR-PLDNR sy-vline
WA_FMBS_S_PO_LOCK_STR-FUND sy-vline
WA_FMBS_S_PO_LOCK_STR-FUNDSCTR sy-vline
WA_FMBS_S_PO_LOCK_STR-CMMTITEM sy-vline
WA_FMBS_S_PO_LOCK_STR-FUNCAREA sy-vline
WA_FMBS_S_PO_LOCK_STR-GRANT_NBR sy-vline
WA_FMBS_S_PO_LOCK_STR-MEASURE sy-vline
WA_FMBS_S_PO_LOCK_STR-USERDIM sy-vline
WA_FMBS_S_PO_LOCK_STR-BUDGET_PD sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.