ABAP Select data from SAP table FMCCAVC_S_ACTUALS_LINE into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FMCCAVC_S_ACTUALS_LINE table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FMCCAVC_S_ACTUALS_LINE. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FMCCAVC_S_ACTUALS_LINE table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FMCCAVC_S_ACTUALS_LINE TYPE STANDARD TABLE OF FMCCAVC_S_ACTUALS_LINE,
      WA_FMCCAVC_S_ACTUALS_LINE TYPE FMCCAVC_S_ACTUALS_LINE,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FMCCAVC_S_ACTUALS_LINE> TYPE FMCCAVC_S_ACTUALS_LINE.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FMCCAVC_S_ACTUALS_LINE.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FMCCAVC_S_ACTUALS_LINE
  INTO TABLE IT_FMCCAVC_S_ACTUALS_LINE.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FMCCAVC_S_ACTUALS_LINE
*  INTO TABLE @DATA(IT_FMCCAVC_S_ACTUALS_LINE2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FMCCAVC_S_ACTUALS_LINE INDEX 1 INTO DATA(WA_FMCCAVC_S_ACTUALS_LINE2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FMCCAVC_S_ACTUALS_LINE ASSIGNING <FMCCAVC_S_ACTUALS_LINE>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FMCCAVC_S_ACTUALS_LINE>-LINENB = 1.
<FMCCAVC_S_ACTUALS_LINE>-COMPANY_CODE = 1.
<FMCCAVC_S_ACTUALS_LINE>-ADDRESS = 1.
<FMCCAVC_S_ACTUALS_LINE>-HKONT = 1.
<FMCCAVC_S_ACTUALS_LINE>-FUND = 1.
ENDLOOP.

LOOP AT IT_FMCCAVC_S_ACTUALS_LINE INTO WA_FMCCAVC_S_ACTUALS_LINE.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FMCCAVC_S_ACTUALS_LINE-BUDGET_PD, sy-vline,
WA_FMCCAVC_S_ACTUALS_LINE-GRANT_NBR, sy-vline,
WA_FMCCAVC_S_ACTUALS_LINE-FAREA, sy-vline,
WA_FMCCAVC_S_ACTUALS_LINE-USERDIM, sy-vline,
WA_FMCCAVC_S_ACTUALS_LINE-FISCYEAR, sy-vline,
WA_FMCCAVC_S_ACTUALS_LINE-LDNR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FMCCAVC_S_ACTUALS_LINE you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FMCCAVC_S_ACTUALS_LINE TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FMCCAVC_S_ACTUALS_LINE INTO WA_FMCCAVC_S_ACTUALS_LINE. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field HKONT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FMCCAVC_S_ACTUALS_LINE-HKONT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FMCCAVC_S_ACTUALS_LINE-HKONT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field GRANT_NBR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FMCCAVC_S_ACTUALS_LINE-GRANT_NBR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FMCCAVC_S_ACTUALS_LINE-GRANT_NBR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field FISCYEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_FMCCAVC_S_ACTUALS_LINE-FISCYEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FMCCAVC_S_ACTUALS_LINE-FISCYEAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field LDNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FMCCAVC_S_ACTUALS_LINE-LDNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FMCCAVC_S_ACTUALS_LINE-LDNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field VERSION CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FMCCAVC_S_ACTUALS_LINE-VERSION IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FMCCAVC_S_ACTUALS_LINE-VERSION.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field REF_DOCNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FMCCAVC_S_ACTUALS_LINE-REF_DOCNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FMCCAVC_S_ACTUALS_LINE-REF_DOCNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FMCCAVC_S_ACTUALS_LINE_STR,
LINENB TYPE STRING,
COMPANY_CODE TYPE STRING,
ADDRESS TYPE STRING,
HKONT TYPE STRING,
FUND TYPE STRING,
BUDGET_PD TYPE STRING,
GRANT_NBR TYPE STRING,
FAREA TYPE STRING,
USERDIM TYPE STRING,
FISCYEAR TYPE STRING,
LDNR TYPE STRING,
VERSION TYPE STRING,
DRCRK TYPE STRING,
WAERS TYPE STRING,
ACTIV TYPE STRING,
REF_DOCNR TYPE STRING,
REF_DOCLN TYPE STRING,
STAT TYPE STRING,
WFSTATE_9 TYPE STRING,
AVC_STATUS TYPE STRING,
POPER TYPE STRING,
TSL TYPE STRING,
HSL TYPE STRING,END OF T_EKKO_STR. DATA: WA_FMCCAVC_S_ACTUALS_LINE_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FMCCAVC_S_ACTUALS_LINE_STR-LINENB sy-vline
WA_FMCCAVC_S_ACTUALS_LINE_STR-COMPANY_CODE sy-vline
WA_FMCCAVC_S_ACTUALS_LINE_STR-ADDRESS sy-vline
WA_FMCCAVC_S_ACTUALS_LINE_STR-HKONT sy-vline
WA_FMCCAVC_S_ACTUALS_LINE_STR-FUND sy-vline
WA_FMCCAVC_S_ACTUALS_LINE_STR-BUDGET_PD sy-vline
WA_FMCCAVC_S_ACTUALS_LINE_STR-GRANT_NBR sy-vline
WA_FMCCAVC_S_ACTUALS_LINE_STR-FAREA sy-vline
WA_FMCCAVC_S_ACTUALS_LINE_STR-USERDIM sy-vline
WA_FMCCAVC_S_ACTUALS_LINE_STR-FISCYEAR sy-vline
WA_FMCCAVC_S_ACTUALS_LINE_STR-LDNR sy-vline
WA_FMCCAVC_S_ACTUALS_LINE_STR-VERSION sy-vline
WA_FMCCAVC_S_ACTUALS_LINE_STR-DRCRK sy-vline
WA_FMCCAVC_S_ACTUALS_LINE_STR-WAERS sy-vline
WA_FMCCAVC_S_ACTUALS_LINE_STR-ACTIV sy-vline
WA_FMCCAVC_S_ACTUALS_LINE_STR-REF_DOCNR sy-vline
WA_FMCCAVC_S_ACTUALS_LINE_STR-REF_DOCLN sy-vline
WA_FMCCAVC_S_ACTUALS_LINE_STR-STAT sy-vline
WA_FMCCAVC_S_ACTUALS_LINE_STR-WFSTATE_9 sy-vline
WA_FMCCAVC_S_ACTUALS_LINE_STR-AVC_STATUS sy-vline
WA_FMCCAVC_S_ACTUALS_LINE_STR-POPER sy-vline
WA_FMCCAVC_S_ACTUALS_LINE_STR-TSL sy-vline
WA_FMCCAVC_S_ACTUALS_LINE_STR-HSL sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.