ABAP Select data from SAP table FMCFSIF into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FMCFSIF table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FMCFSIF. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FMCFSIF table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FMCFSIF TYPE STANDARD TABLE OF FMCFSIF,
      WA_FMCFSIF TYPE FMCFSIF,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FMCFSIF> TYPE FMCFSIF.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FMCFSIF.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FMCFSIF
  INTO TABLE IT_FMCFSIF.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FMCFSIF
*  INTO TABLE @DATA(IT_FMCFSIF2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FMCFSIF INDEX 1 INTO DATA(WA_FMCFSIF2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FMCFSIF ASSIGNING <FMCFSIF>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FMCFSIF>-MANDT = 1.
<FMCFSIF>-FMBELNR = 1.
<FMCFSIF>-FIKRS = 1.
<FMCFSIF>-FMBUZEI = 1.
<FMCFSIF>-RLDNR = 1.
ENDLOOP.

LOOP AT IT_FMCFSIF INTO WA_FMCFSIF.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FMCFSIF-GJAHR, sy-vline,
WA_FMCFSIF-STUNR, sy-vline,
WA_FMCFSIF-XREAL, sy-vline,
WA_FMCFSIF-TWAER, sy-vline,
WA_FMCFSIF-FKBTR, sy-vline,
WA_FMCFSIF-TRBTR, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FMCFSIF you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FMCFSIF TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FMCFSIF INTO WA_FMCFSIF. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field FMBELNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FMCFSIF-FMBELNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FMCFSIF-FMBELNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RLDNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FMCFSIF-RLDNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FMCFSIF-RLDNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field GJAHR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_FMCFSIF-GJAHR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FMCFSIF-GJAHR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field GJAHR_REF CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_FMCFSIF-GJAHR_REF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FMCFSIF-GJAHR_REF.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field BELNR_REF CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FMCFSIF-BELNR_REF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FMCFSIF-BELNR_REF.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field WRTTP CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FMCFSIF-WRTTP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FMCFSIF-WRTTP.
WRITE:/ 'New Value:', ld_input.

*Conversion exit FMCIS, internal->external for field FIPOS CALL FUNCTION 'CONVERSION_EXIT_FMCIS_OUTPUT' EXPORTING input = WA_FMCFSIF-FIPOS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FMCFSIF-FIPOS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit FMCIL, internal->external for field FIPEX CALL FUNCTION 'CONVERSION_EXIT_FMCIL_OUTPUT' EXPORTING input = WA_FMCFSIF-FIPEX IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FMCFSIF-FIPEX.
WRITE:/ 'New Value:', ld_input.

*Conversion exit FMCIS, internal->external for field FIPOS_E CALL FUNCTION 'CONVERSION_EXIT_FMCIS_OUTPUT' EXPORTING input = WA_FMCFSIF-FIPOS_E IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FMCFSIF-FIPOS_E.
WRITE:/ 'New Value:', ld_input.

*Conversion exit FMCIL, internal->external for field FIPEX_E CALL FUNCTION 'CONVERSION_EXIT_FMCIL_OUTPUT' EXPORTING input = WA_FMCFSIF-FIPEX_E IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FMCFSIF-FIPEX_E.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field GNJHR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_FMCFSIF-GNJHR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FMCFSIF-GNJHR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RLDNR_E CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FMCFSIF-RLDNR_E IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FMCFSIF-RLDNR_E.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field GRANT_NBR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FMCFSIF-GRANT_NBR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FMCFSIF-GRANT_NBR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FMCFSIF_STR,
MANDT TYPE STRING,
FMBELNR TYPE STRING,
FIKRS TYPE STRING,
FMBUZEI TYPE STRING,
RLDNR TYPE STRING,
GJAHR TYPE STRING,
STUNR TYPE STRING,
XREAL TYPE STRING,
TWAER TYPE STRING,
FKBTR TYPE STRING,
TRBTR TYPE STRING,
BUKRS_REF TYPE STRING,
GJAHR_REF TYPE STRING,
BELNR_REF TYPE STRING,
BUZEI_REF TYPE STRING,
WRTTP TYPE STRING,
CFSTAT TYPE STRING,
CPUDTSEL TYPE STRING,
CPUTMSEL TYPE STRING,
UNAMESEL TYPE STRING,
CPUDTCF TYPE STRING,
CPUTMCF TYPE STRING,
UNAMECF TYPE STRING,
FISTL TYPE STRING,
FONDS TYPE STRING,
FIPOS TYPE STRING,
FIPEX TYPE STRING,
FAREA TYPE STRING,
FISTL_E TYPE STRING,
FONDS_E TYPE STRING,
FIPOS_E TYPE STRING,
FIPEX_E TYPE STRING,
FAREA_E TYPE STRING,
CFRULE TYPE STRING,
FLG_AC TYPE STRING,
GNJHR TYPE STRING,
RLDNR_E TYPE STRING,
CFLEV TYPE STRING,
STATS TYPE STRING,
GRANT_NBR TYPE STRING,END OF T_EKKO_STR. DATA: WA_FMCFSIF_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FMCFSIF_STR-MANDT sy-vline
WA_FMCFSIF_STR-FMBELNR sy-vline
WA_FMCFSIF_STR-FIKRS sy-vline
WA_FMCFSIF_STR-FMBUZEI sy-vline
WA_FMCFSIF_STR-RLDNR sy-vline
WA_FMCFSIF_STR-GJAHR sy-vline
WA_FMCFSIF_STR-STUNR sy-vline
WA_FMCFSIF_STR-XREAL sy-vline
WA_FMCFSIF_STR-TWAER sy-vline
WA_FMCFSIF_STR-FKBTR sy-vline
WA_FMCFSIF_STR-TRBTR sy-vline
WA_FMCFSIF_STR-BUKRS_REF sy-vline
WA_FMCFSIF_STR-GJAHR_REF sy-vline
WA_FMCFSIF_STR-BELNR_REF sy-vline
WA_FMCFSIF_STR-BUZEI_REF sy-vline
WA_FMCFSIF_STR-WRTTP sy-vline
WA_FMCFSIF_STR-CFSTAT sy-vline
WA_FMCFSIF_STR-CPUDTSEL sy-vline
WA_FMCFSIF_STR-CPUTMSEL sy-vline
WA_FMCFSIF_STR-UNAMESEL sy-vline
WA_FMCFSIF_STR-CPUDTCF sy-vline
WA_FMCFSIF_STR-CPUTMCF sy-vline
WA_FMCFSIF_STR-UNAMECF sy-vline
WA_FMCFSIF_STR-FISTL sy-vline
WA_FMCFSIF_STR-FONDS sy-vline
WA_FMCFSIF_STR-FIPOS sy-vline
WA_FMCFSIF_STR-FIPEX sy-vline
WA_FMCFSIF_STR-FAREA sy-vline
WA_FMCFSIF_STR-FISTL_E sy-vline
WA_FMCFSIF_STR-FONDS_E sy-vline
WA_FMCFSIF_STR-FIPOS_E sy-vline
WA_FMCFSIF_STR-FIPEX_E sy-vline
WA_FMCFSIF_STR-FAREA_E sy-vline
WA_FMCFSIF_STR-CFRULE sy-vline
WA_FMCFSIF_STR-FLG_AC sy-vline
WA_FMCFSIF_STR-GNJHR sy-vline
WA_FMCFSIF_STR-RLDNR_E sy-vline
WA_FMCFSIF_STR-CFLEV sy-vline
WA_FMCFSIF_STR-STATS sy-vline
WA_FMCFSIF_STR-GRANT_NBR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.