ABAP Select data from SAP table FMFG_DRV_FMFUSE_OUT into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP FMFG_DRV_FMFUSE_OUT table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FMFG_DRV_FMFUSE_OUT. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the FMFG_DRV_FMFUSE_OUT table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_FMFG_DRV_FMFUSE_OUT TYPE STANDARD TABLE OF FMFG_DRV_FMFUSE_OUT, WA_FMFG_DRV_FMFUSE_OUT TYPE FMFG_DRV_FMFUSE_OUT, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <FMFG_DRV_FMFUSE_OUT> TYPE FMFG_DRV_FMFUSE_OUT. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_FMFG_DRV_FMFUSE_OUT. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM FMFG_DRV_FMFUSE_OUT INTO TABLE IT_FMFG_DRV_FMFUSE_OUT. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM FMFG_DRV_FMFUSE_OUT * INTO TABLE @DATA(IT_FMFG_DRV_FMFUSE_OUT2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_FMFG_DRV_FMFUSE_OUT INDEX 1 INTO DATA(WA_FMFG_DRV_FMFUSE_OUT2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_FMFG_DRV_FMFUSE_OUT ASSIGNING <FMFG_DRV_FMFUSE_OUT>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<FMFG_DRV_FMFUSE_OUT>-DEPT_REG = 1.
<FMFG_DRV_FMFUSE_OUT>-DEPT_TRAN = 1.
<FMFG_DRV_FMFUSE_OUT>-MAIN_ACCT = 1.
<FMFG_DRV_FMFUSE_OUT>-SUB_ACCT = 1.
<FMFG_DRV_FMFUSE_OUT>-GTAS_REL = 1.
ENDLOOP. LOOP AT IT_FMFG_DRV_FMFUSE_OUT INTO WA_FMFG_DRV_FMFUSE_OUT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_FMFG_DRV_FMFUSE_OUT-SUBLEVL, sy-vline,
WA_FMFG_DRV_FMFUSE_OUT-AGENCID, sy-vline,
WA_FMFG_DRV_FMFUSE_OUT-ALTRAID, sy-vline,
WA_FMFG_DRV_FMFUSE_OUT-BEGPER, sy-vline,
WA_FMFG_DRV_FMFUSE_OUT-ENDPER, sy-vline,
WA_FMFG_DRV_FMFUSE_OUT-AVTYPE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FMFG_DRV_FMFUSE_OUT you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FMFG_DRV_FMFUSE_OUT TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FMFG_DRV_FMFUSE_OUT INTO WA_FMFG_DRV_FMFUSE_OUT. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit GJAHR, internal->external for field BEGPER CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_FMFG_DRV_FMFUSE_OUT-BEGPER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FMFG_DRV_FMFUSE_OUT-BEGPER.
WRITE:/ 'New Value:', ld_input.
*Conversion exit GJAHR, internal->external for field ENDPER CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_FMFG_DRV_FMFUSE_OUT-ENDPER IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FMFG_DRV_FMFUSE_OUT-ENDPER.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FMFG_DRV_FMFUSE_OUT_STR,
DEPT_REG TYPE STRING,
DEPT_TRAN TYPE STRING,
MAIN_ACCT TYPE STRING,
SUB_ACCT TYPE STRING,
GTAS_REL TYPE STRING,
SUBLEVL TYPE STRING,
AGENCID TYPE STRING,
ALTRAID TYPE STRING,
BEGPER TYPE STRING,
ENDPER TYPE STRING,
AVTYPE TYPE STRING,END OF T_EKKO_STR. DATA: WA_FMFG_DRV_FMFUSE_OUT_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FMFG_DRV_FMFUSE_OUT_STR-DEPT_REG sy-vline
WA_FMFG_DRV_FMFUSE_OUT_STR-DEPT_TRAN sy-vline
WA_FMFG_DRV_FMFUSE_OUT_STR-MAIN_ACCT sy-vline
WA_FMFG_DRV_FMFUSE_OUT_STR-SUB_ACCT sy-vline
WA_FMFG_DRV_FMFUSE_OUT_STR-GTAS_REL sy-vline
WA_FMFG_DRV_FMFUSE_OUT_STR-SUBLEVL sy-vline
WA_FMFG_DRV_FMFUSE_OUT_STR-AGENCID sy-vline
WA_FMFG_DRV_FMFUSE_OUT_STR-ALTRAID sy-vline
WA_FMFG_DRV_FMFUSE_OUT_STR-BEGPER sy-vline
WA_FMFG_DRV_FMFUSE_OUT_STR-ENDPER sy-vline
WA_FMFG_DRV_FMFUSE_OUT_STR-AVTYPE sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.