ABAP Select data from SAP table FOPCCASETL into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FOPCCASETL table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FOPCCASETL. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FOPCCASETL table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FOPCCASETL TYPE STANDARD TABLE OF FOPCCASETL,
      WA_FOPCCASETL TYPE FOPCCASETL,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FOPCCASETL> TYPE FOPCCASETL.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FOPCCASETL.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FOPCCASETL
  INTO TABLE IT_FOPCCASETL.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FOPCCASETL
*  INTO TABLE @DATA(IT_FOPCCASETL2).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FOPCCASETL INDEX 1 INTO DATA(WA_FOPCCASETL2).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FOPCCASETL ASSIGNING <FOPCCASETL>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FOPCCASETL>-MANDT = 1.
<FOPCCASETL>-CASE_GUID = 1.
<FOPCCASETL>-DATE_BEGIN = 1.
<FOPCCASETL>-DATE_END = 1.
<FOPCCASETL>-TIMEFRAME = 1.
ENDLOOP.

LOOP AT IT_FOPCCASETL INTO WA_FOPCCASETL.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FOPCCASETL-TF_YEAR, sy-vline,
WA_FOPCCASETL-TESTER_NUMB, sy-vline,
WA_FOPCCASETL-TESTING_DATE, sy-vline,
WA_FOPCCASETL-TESTING_METHOD, sy-vline,
WA_FOPCCASETL-TESTING_TEC, sy-vline,
WA_FOPCCASETL-TEST_EXCEPTION, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FOPCCASETL you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FOPCCASETL TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FOPCCASETL INTO WA_FOPCCASETL. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit TSTPS, internal->external for field TIMESTAMPDLL CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_FOPCCASETL-TIMESTAMPDLL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FOPCCASETL-TIMESTAMPDLL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTPS, internal->external for field TIMESTAMPDLV CALL FUNCTION 'CONVERSION_EXIT_TSTPS_OUTPUT' EXPORTING input = WA_FOPCCASETL-TIMESTAMPDLV IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FOPCCASETL-TIMESTAMPDLV.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FOPCCASETL_STR,
MANDT TYPE STRING,
CASE_GUID TYPE STRING,
DATE_BEGIN TYPE STRING,
DATE_END TYPE STRING,
TIMEFRAME TYPE STRING,
TF_YEAR TYPE STRING,
TESTER_NUMB TYPE STRING,
TESTING_DATE TYPE STRING,
TESTING_METHOD TYPE STRING,
TESTING_TEC TYPE STRING,
TEST_EXCEPTION TYPE STRING,
TESTING_RATING TYPE STRING,
MAIN_USERDLL TYPE STRING,
TIMESTAMPDLL TYPE STRING,
VALIDATED_BY_UN TYPE STRING,
VALIDATION_DATE TYPE STRING,
MAIN_USERDLV TYPE STRING,
TIMESTAMPDLV TYPE STRING,
CF_STATUS TYPE STRING,
EXT_SYSTEM TYPE STRING,
EXT_TESTER TYPE STRING,END OF T_EKKO_STR. DATA: WA_FOPCCASETL_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FOPCCASETL_STR-MANDT sy-vline
WA_FOPCCASETL_STR-CASE_GUID sy-vline
WA_FOPCCASETL_STR-DATE_BEGIN sy-vline
WA_FOPCCASETL_STR-DATE_END sy-vline
WA_FOPCCASETL_STR-TIMEFRAME sy-vline
WA_FOPCCASETL_STR-TF_YEAR sy-vline
WA_FOPCCASETL_STR-TESTER_NUMB sy-vline
WA_FOPCCASETL_STR-TESTING_DATE sy-vline
WA_FOPCCASETL_STR-TESTING_METHOD sy-vline
WA_FOPCCASETL_STR-TESTING_TEC sy-vline
WA_FOPCCASETL_STR-TEST_EXCEPTION sy-vline
WA_FOPCCASETL_STR-TESTING_RATING sy-vline
WA_FOPCCASETL_STR-MAIN_USERDLL sy-vline
WA_FOPCCASETL_STR-TIMESTAMPDLL sy-vline
WA_FOPCCASETL_STR-VALIDATED_BY_UN sy-vline
WA_FOPCCASETL_STR-VALIDATION_DATE sy-vline
WA_FOPCCASETL_STR-MAIN_USERDLV sy-vline
WA_FOPCCASETL_STR-TIMESTAMPDLV sy-vline
WA_FOPCCASETL_STR-CF_STATUS sy-vline
WA_FOPCCASETL_STR-EXT_SYSTEM sy-vline
WA_FOPCCASETL_STR-EXT_TESTER sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.