ABAP Select data from SAP table FRE_BIF_MARM_ATTR_STY into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP FRE_BIF_MARM_ATTR_STY table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FRE_BIF_MARM_ATTR_STY. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the FRE_BIF_MARM_ATTR_STY table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_FRE_BIF_MARM_ATTR_STY TYPE STANDARD TABLE OF FRE_BIF_MARM_ATTR_STY, WA_FRE_BIF_MARM_ATTR_STY TYPE FRE_BIF_MARM_ATTR_STY, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <FRE_BIF_MARM_ATTR_STY> TYPE FRE_BIF_MARM_ATTR_STY. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_FRE_BIF_MARM_ATTR_STY. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM FRE_BIF_MARM_ATTR_STY INTO TABLE IT_FRE_BIF_MARM_ATTR_STY. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM FRE_BIF_MARM_ATTR_STY * INTO TABLE @DATA(IT_FRE_BIF_MARM_ATTR_STY2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_FRE_BIF_MARM_ATTR_STY INDEX 1 INTO DATA(WA_FRE_BIF_MARM_ATTR_STY2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_FRE_BIF_MARM_ATTR_STY ASSIGNING <FRE_BIF_MARM_ATTR_STY>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<FRE_BIF_MARM_ATTR_STY>-UMREZ = 1.
<FRE_BIF_MARM_ATTR_STY>-UMREZ_X = 1.
<FRE_BIF_MARM_ATTR_STY>-UMREN = 1.
<FRE_BIF_MARM_ATTR_STY>-UMREN_X = 1.
<FRE_BIF_MARM_ATTR_STY>-EAN11 = 1.
ENDLOOP. LOOP AT IT_FRE_BIF_MARM_ATTR_STY INTO WA_FRE_BIF_MARM_ATTR_STY. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_FRE_BIF_MARM_ATTR_STY-EAN11_X, sy-vline,
WA_FRE_BIF_MARM_ATTR_STY-BRGEW, sy-vline,
WA_FRE_BIF_MARM_ATTR_STY-BRGEW_X, sy-vline,
WA_FRE_BIF_MARM_ATTR_STY-NTGEW, sy-vline,
WA_FRE_BIF_MARM_ATTR_STY-NTGEW_X, sy-vline,
WA_FRE_BIF_MARM_ATTR_STY-GEWEI, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FRE_BIF_MARM_ATTR_STY you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FRE_BIF_MARM_ATTR_STY TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FRE_BIF_MARM_ATTR_STY INTO WA_FRE_BIF_MARM_ATTR_STY. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit EAN11, internal->external for field EAN11 CALL FUNCTION 'CONVERSION_EXIT_EAN11_OUTPUT' EXPORTING input = WA_FRE_BIF_MARM_ATTR_STY-EAN11 IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FRE_BIF_MARM_ATTR_STY-EAN11.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field GEWEI CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_FRE_BIF_MARM_ATTR_STY-GEWEI IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FRE_BIF_MARM_ATTR_STY-GEWEI.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field MEABM CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_FRE_BIF_MARM_ATTR_STY-MEABM IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FRE_BIF_MARM_ATTR_STY-MEABM.
WRITE:/ 'New Value:', ld_input.
*Conversion exit CUNIT, internal->external for field VOLEH CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_FRE_BIF_MARM_ATTR_STY-VOLEH IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FRE_BIF_MARM_ATTR_STY-VOLEH.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FRE_BIF_MARM_ATTR_STY_STR,
UMREZ TYPE STRING,
UMREZ_X TYPE STRING,
UMREN TYPE STRING,
UMREN_X TYPE STRING,
EAN11 TYPE STRING,
EAN11_X TYPE STRING,
BRGEW TYPE STRING,
BRGEW_X TYPE STRING,
NTGEW TYPE STRING,
NTGEW_X TYPE STRING,
GEWEI TYPE STRING,
GEWEI_X TYPE STRING,
LAENG TYPE STRING,
LAENG_X TYPE STRING,
BREIT TYPE STRING,
BREIT_X TYPE STRING,
HOEHE TYPE STRING,
HOEHE_X TYPE STRING,
MEABM TYPE STRING,
MEABM_X TYPE STRING,
VOLUM TYPE STRING,
VOLUM_X TYPE STRING,
VOLEH TYPE STRING,
VOLEH_X TYPE STRING,END OF T_EKKO_STR. DATA: WA_FRE_BIF_MARM_ATTR_STY_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FRE_BIF_MARM_ATTR_STY_STR-UMREZ sy-vline
WA_FRE_BIF_MARM_ATTR_STY_STR-UMREZ_X sy-vline
WA_FRE_BIF_MARM_ATTR_STY_STR-UMREN sy-vline
WA_FRE_BIF_MARM_ATTR_STY_STR-UMREN_X sy-vline
WA_FRE_BIF_MARM_ATTR_STY_STR-EAN11 sy-vline
WA_FRE_BIF_MARM_ATTR_STY_STR-EAN11_X sy-vline
WA_FRE_BIF_MARM_ATTR_STY_STR-BRGEW sy-vline
WA_FRE_BIF_MARM_ATTR_STY_STR-BRGEW_X sy-vline
WA_FRE_BIF_MARM_ATTR_STY_STR-NTGEW sy-vline
WA_FRE_BIF_MARM_ATTR_STY_STR-NTGEW_X sy-vline
WA_FRE_BIF_MARM_ATTR_STY_STR-GEWEI sy-vline
WA_FRE_BIF_MARM_ATTR_STY_STR-GEWEI_X sy-vline
WA_FRE_BIF_MARM_ATTR_STY_STR-LAENG sy-vline
WA_FRE_BIF_MARM_ATTR_STY_STR-LAENG_X sy-vline
WA_FRE_BIF_MARM_ATTR_STY_STR-BREIT sy-vline
WA_FRE_BIF_MARM_ATTR_STY_STR-BREIT_X sy-vline
WA_FRE_BIF_MARM_ATTR_STY_STR-HOEHE sy-vline
WA_FRE_BIF_MARM_ATTR_STY_STR-HOEHE_X sy-vline
WA_FRE_BIF_MARM_ATTR_STY_STR-MEABM sy-vline
WA_FRE_BIF_MARM_ATTR_STY_STR-MEABM_X sy-vline
WA_FRE_BIF_MARM_ATTR_STY_STR-VOLUM sy-vline
WA_FRE_BIF_MARM_ATTR_STY_STR-VOLUM_X sy-vline
WA_FRE_BIF_MARM_ATTR_STY_STR-VOLEH sy-vline
WA_FRE_BIF_MARM_ATTR_STY_STR-VOLEH_X sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.