ABAP Select data from SAP table FRE_MD_TPSRC_STY_60 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FRE_MD_TPSRC_STY_60 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FRE_MD_TPSRC_STY_60. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FRE_MD_TPSRC_STY_60 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FRE_MD_TPSRC_STY_60 TYPE STANDARD TABLE OF FRE_MD_TPSRC_STY_60,
      WA_FRE_MD_TPSRC_STY_60 TYPE FRE_MD_TPSRC_STY_60,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FRE_MD_TPSRC_STY_60> TYPE FRE_MD_TPSRC_STY_60.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FRE_MD_TPSRC_STY_60.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FRE_MD_TPSRC_STY_60
  INTO TABLE IT_FRE_MD_TPSRC_STY_60.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FRE_MD_TPSRC_STY_60
*  INTO TABLE @DATA(IT_FRE_MD_TPSRC_STY_602).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FRE_MD_TPSRC_STY_60 INDEX 1 INTO DATA(WA_FRE_MD_TPSRC_STY_602).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FRE_MD_TPSRC_STY_60 ASSIGNING <FRE_MD_TPSRC_STY_60>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FRE_MD_TPSRC_STY_60>-FUNCTION = 1.
<FRE_MD_TPSRC_STY_60>-IBZQID = 1.
<FRE_MD_TPSRC_STY_60>-TDSRC = 1.
<FRE_MD_TPSRC_STY_60>-EBELN = 1.
<FRE_MD_TPSRC_STY_60>-EBELP = 1.
ENDLOOP.

LOOP AT IT_FRE_MD_TPSRC_STY_60 INTO WA_FRE_MD_TPSRC_STY_60.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FRE_MD_TPSRC_STY_60-EKORG, sy-vline,
WA_FRE_MD_TPSRC_STY_60-LOCNOTO, sy-vline,
WA_FRE_MD_TPSRC_STY_60-LOCNOTOTYPE, sy-vline,
WA_FRE_MD_TPSRC_STY_60-MATNR, sy-vline,
WA_FRE_MD_TPSRC_STY_60-LOCNOFR, sy-vline,
WA_FRE_MD_TPSRC_STY_60-LOCNOFRTYPE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FRE_MD_TPSRC_STY_60 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FRE_MD_TPSRC_STY_60 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FRE_MD_TPSRC_STY_60 INTO WA_FRE_MD_TPSRC_STY_60. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit CUNIT, internal->external for field BSTME CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_FRE_MD_TPSRC_STY_60-BSTME IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FRE_MD_TPSRC_STY_60-BSTME.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTRG, internal->external for field PLIFZ CALL FUNCTION 'CONVERSION_EXIT_TSTRG_OUTPUT' EXPORTING input = WA_FRE_MD_TPSRC_STY_60-PLIFZ IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FRE_MD_TPSRC_STY_60-PLIFZ.
WRITE:/ 'New Value:', ld_input.

*Conversion exit TSTRG, internal->external for field TGIPRT CALL FUNCTION 'CONVERSION_EXIT_TSTRG_OUTPUT' EXPORTING input = WA_FRE_MD_TPSRC_STY_60-TGIPRT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FRE_MD_TPSRC_STY_60-TGIPRT.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FRE_MD_TPSRC_STY_60_STR,
FUNCTION TYPE STRING,
IBZQID TYPE STRING,
TDSRC TYPE STRING,
EBELN TYPE STRING,
EBELP TYPE STRING,
EKORG TYPE STRING,
LOCNOTO TYPE STRING,
LOCNOTOTYPE TYPE STRING,
MATNR TYPE STRING,
LOCNOFR TYPE STRING,
LOCNOFRTYPE TYPE STRING,
CONSI TYPE STRING,
SUBCO TYPE STRING,
VALFR TYPE STRING,
VALFR_X TYPE STRING,
VALTO TYPE STRING,
VALTO_X TYPE STRING,
BZQ_ACTIVE TYPE STRING,
BZQ_ACTIVE_X TYPE STRING,
BSTME TYPE STRING,
BSTME_X TYPE STRING,
BSTME_ISO TYPE STRING,
BSTME_ISO_X TYPE STRING,
MEASGRSUP TYPE STRING,
MEASGRSUP_X TYPE STRING,
PLIFZ TYPE STRING,
PLIFZ_X TYPE STRING,
IDNLF TYPE STRING,
IDNLF_X TYPE STRING,
VARPUOM TYPE STRING,
VARPUOM_X TYPE STRING,
PRORD TYPE STRING,
PRORD_X TYPE STRING,
PROCYC TYPE STRING,
PROCYC_X TYPE STRING,
SLSNR TYPE STRING,
SLSNR_X TYPE STRING,
TGIPRT TYPE STRING,
TGIPRT_X TYPE STRING,
LOC_DYN TYPE STRING,
PURCHASE_GRP TYPE STRING,
PURCHASE_GRP_X TYPE STRING,
SPRIO TYPE STRING,
SPRIO_X TYPE STRING,
MINLS TYPE STRING,
MINLS_X TYPE STRING,
MAXLS TYPE STRING,
MAXLS_X TYPE STRING,
PROCESSINGMETH TYPE STRING,
PROCESSINGMETH_X TYPE STRING,END OF T_EKKO_STR. DATA: WA_FRE_MD_TPSRC_STY_60_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FRE_MD_TPSRC_STY_60_STR-FUNCTION sy-vline
WA_FRE_MD_TPSRC_STY_60_STR-IBZQID sy-vline
WA_FRE_MD_TPSRC_STY_60_STR-TDSRC sy-vline
WA_FRE_MD_TPSRC_STY_60_STR-EBELN sy-vline
WA_FRE_MD_TPSRC_STY_60_STR-EBELP sy-vline
WA_FRE_MD_TPSRC_STY_60_STR-EKORG sy-vline
WA_FRE_MD_TPSRC_STY_60_STR-LOCNOTO sy-vline
WA_FRE_MD_TPSRC_STY_60_STR-LOCNOTOTYPE sy-vline
WA_FRE_MD_TPSRC_STY_60_STR-MATNR sy-vline
WA_FRE_MD_TPSRC_STY_60_STR-LOCNOFR sy-vline
WA_FRE_MD_TPSRC_STY_60_STR-LOCNOFRTYPE sy-vline
WA_FRE_MD_TPSRC_STY_60_STR-CONSI sy-vline
WA_FRE_MD_TPSRC_STY_60_STR-SUBCO sy-vline
WA_FRE_MD_TPSRC_STY_60_STR-VALFR sy-vline
WA_FRE_MD_TPSRC_STY_60_STR-VALFR_X sy-vline
WA_FRE_MD_TPSRC_STY_60_STR-VALTO sy-vline
WA_FRE_MD_TPSRC_STY_60_STR-VALTO_X sy-vline
WA_FRE_MD_TPSRC_STY_60_STR-BZQ_ACTIVE sy-vline
WA_FRE_MD_TPSRC_STY_60_STR-BZQ_ACTIVE_X sy-vline
WA_FRE_MD_TPSRC_STY_60_STR-BSTME sy-vline
WA_FRE_MD_TPSRC_STY_60_STR-BSTME_X sy-vline
WA_FRE_MD_TPSRC_STY_60_STR-BSTME_ISO sy-vline
WA_FRE_MD_TPSRC_STY_60_STR-BSTME_ISO_X sy-vline
WA_FRE_MD_TPSRC_STY_60_STR-MEASGRSUP sy-vline
WA_FRE_MD_TPSRC_STY_60_STR-MEASGRSUP_X sy-vline
WA_FRE_MD_TPSRC_STY_60_STR-PLIFZ sy-vline
WA_FRE_MD_TPSRC_STY_60_STR-PLIFZ_X sy-vline
WA_FRE_MD_TPSRC_STY_60_STR-IDNLF sy-vline
WA_FRE_MD_TPSRC_STY_60_STR-IDNLF_X sy-vline
WA_FRE_MD_TPSRC_STY_60_STR-VARPUOM sy-vline
WA_FRE_MD_TPSRC_STY_60_STR-VARPUOM_X sy-vline
WA_FRE_MD_TPSRC_STY_60_STR-PRORD sy-vline
WA_FRE_MD_TPSRC_STY_60_STR-PRORD_X sy-vline
WA_FRE_MD_TPSRC_STY_60_STR-PROCYC sy-vline
WA_FRE_MD_TPSRC_STY_60_STR-PROCYC_X sy-vline
WA_FRE_MD_TPSRC_STY_60_STR-SLSNR sy-vline
WA_FRE_MD_TPSRC_STY_60_STR-SLSNR_X sy-vline
WA_FRE_MD_TPSRC_STY_60_STR-TGIPRT sy-vline
WA_FRE_MD_TPSRC_STY_60_STR-TGIPRT_X sy-vline
WA_FRE_MD_TPSRC_STY_60_STR-LOC_DYN sy-vline
WA_FRE_MD_TPSRC_STY_60_STR-PURCHASE_GRP sy-vline
WA_FRE_MD_TPSRC_STY_60_STR-PURCHASE_GRP_X sy-vline
WA_FRE_MD_TPSRC_STY_60_STR-SPRIO sy-vline
WA_FRE_MD_TPSRC_STY_60_STR-SPRIO_X sy-vline
WA_FRE_MD_TPSRC_STY_60_STR-MINLS sy-vline
WA_FRE_MD_TPSRC_STY_60_STR-MINLS_X sy-vline
WA_FRE_MD_TPSRC_STY_60_STR-MAXLS sy-vline
WA_FRE_MD_TPSRC_STY_60_STR-MAXLS_X sy-vline
WA_FRE_MD_TPSRC_STY_60_STR-PROCESSINGMETH sy-vline
WA_FRE_MD_TPSRC_STY_60_STR-PROCESSINGMETH_X sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.