ABAP Select data from SAP table FRMLS_DYNP_STD_SUB into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP FRMLS_DYNP_STD_SUB table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FRMLS_DYNP_STD_SUB. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the FRMLS_DYNP_STD_SUB table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_FRMLS_DYNP_STD_SUB TYPE STANDARD TABLE OF FRMLS_DYNP_STD_SUB, WA_FRMLS_DYNP_STD_SUB TYPE FRMLS_DYNP_STD_SUB, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <FRMLS_DYNP_STD_SUB> TYPE FRMLS_DYNP_STD_SUB. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_FRMLS_DYNP_STD_SUB. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM FRMLS_DYNP_STD_SUB INTO TABLE IT_FRMLS_DYNP_STD_SUB. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM FRMLS_DYNP_STD_SUB * INTO TABLE @DATA(IT_FRMLS_DYNP_STD_SUB2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_FRMLS_DYNP_STD_SUB INDEX 1 INTO DATA(WA_FRMLS_DYNP_STD_SUB2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_FRMLS_DYNP_STD_SUB ASSIGNING <FRMLS_DYNP_STD_SUB>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<FRMLS_DYNP_STD_SUB>-RECN = 1.
<FRMLS_DYNP_STD_SUB>-SUBID = 1.
<FRMLS_DYNP_STD_SUB>-STREAM_ID = 1.
<FRMLS_DYNP_STD_SUB>-SUB_TXT = 1.
<FRMLS_DYNP_STD_SUB>-ICONID = 1.
ENDLOOP. LOOP AT IT_FRMLS_DYNP_STD_SUB INTO WA_FRMLS_DYNP_STD_SUB. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_FRMLS_DYNP_STD_SUB-LINEMODE, sy-vline,
WA_FRMLS_DYNP_STD_SUB-ROW_ID, sy-vline,
WA_FRMLS_DYNP_STD_SUB-ENTITY, sy-vline,
WA_FRMLS_DYNP_STD_SUB-SORT, sy-vline,
WA_FRMLS_DYNP_STD_SUB-FIX_BUT, sy-vline,
WA_FRMLS_DYNP_STD_SUB-FIX, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FRMLS_DYNP_STD_SUB you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FRMLS_DYNP_STD_SUB TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FRMLS_DYNP_STD_SUB INTO WA_FRMLS_DYNP_STD_SUB. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit SPEC1, internal->external for field SUBID CALL FUNCTION 'CONVERSION_EXIT_SPEC1_OUTPUT' EXPORTING input = WA_FRMLS_DYNP_STD_SUB-SUBID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FRMLS_DYNP_STD_SUB-SUBID.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FRMLS_DYNP_STD_SUB_STR,
RECN TYPE STRING,
SUBID TYPE STRING,
STREAM_ID TYPE STRING,
SUB_TXT TYPE STRING,
ICONID TYPE STRING,
LINEMODE TYPE STRING,
ROW_ID TYPE STRING,
ENTITY TYPE STRING,
SORT TYPE STRING,
FIX_BUT TYPE STRING,
FIX TYPE STRING,
SEC_OUT TYPE STRING,
PO_FLG TYPE STRING,
STREAM TYPE STRING,
POSNR TYPE STRING,
QTY TYPE STRING,
TS TYPE STRING,
TS_FACT TYPE STRING,
NUTR01 TYPE STRING,
NUTR02 TYPE STRING,
NUTR03 TYPE STRING,
NUTR04 TYPE STRING,
NUTR05 TYPE STRING,
NUTR06 TYPE STRING,
NUTR07 TYPE STRING,
NUTR08 TYPE STRING,
NUTR09 TYPE STRING,
NUTR10 TYPE STRING,
NUTR11 TYPE STRING,
NUTR12 TYPE STRING,
NUTR13 TYPE STRING,
NUTR14 TYPE STRING,
NUTR15 TYPE STRING,
NUTR16 TYPE STRING,
NUTR17 TYPE STRING,
NUTR18 TYPE STRING,
NUTR19 TYPE STRING,
NUTR20 TYPE STRING,
NUTR21 TYPE STRING,
NUTR22 TYPE STRING,
NUTR23 TYPE STRING,
NUTR24 TYPE STRING,
NUTR25 TYPE STRING,
NUTR26 TYPE STRING,
NUTR27 TYPE STRING,
NUTR28 TYPE STRING,
NUTR29 TYPE STRING,
NUTR30 TYPE STRING,
NUTR31 TYPE STRING,
NUTR32 TYPE STRING,
NUTR33 TYPE STRING,
NUTR34 TYPE STRING,
NUTR35 TYPE STRING,
NUTR36 TYPE STRING,
NUTR37 TYPE STRING,
NUTR38 TYPE STRING,
NUTR39 TYPE STRING,
NUTR40 TYPE STRING,
NUTR41 TYPE STRING,
NUTR42 TYPE STRING,
NUTR43 TYPE STRING,
NUTR44 TYPE STRING,
NUTR45 TYPE STRING,
NUTR46 TYPE STRING,
NUTR47 TYPE STRING,
NUTR48 TYPE STRING,
NUTR49 TYPE STRING,
NUTR50 TYPE STRING,
RC TYPE STRING,
ST TYPE STRING,
CT TYPE STRING,END OF T_EKKO_STR. DATA: WA_FRMLS_DYNP_STD_SUB_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-RECN sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-SUBID sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-STREAM_ID sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-SUB_TXT sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-ICONID sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-LINEMODE sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-ROW_ID sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-ENTITY sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-SORT sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-FIX_BUT sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-FIX sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-SEC_OUT sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-PO_FLG sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-STREAM sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-POSNR sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-QTY sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-TS sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-TS_FACT sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-NUTR01 sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-NUTR02 sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-NUTR03 sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-NUTR04 sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-NUTR05 sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-NUTR06 sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-NUTR07 sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-NUTR08 sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-NUTR09 sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-NUTR10 sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-NUTR11 sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-NUTR12 sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-NUTR13 sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-NUTR14 sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-NUTR15 sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-NUTR16 sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-NUTR17 sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-NUTR18 sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-NUTR19 sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-NUTR20 sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-NUTR21 sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-NUTR22 sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-NUTR23 sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-NUTR24 sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-NUTR25 sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-NUTR26 sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-NUTR27 sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-NUTR28 sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-NUTR29 sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-NUTR30 sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-NUTR31 sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-NUTR32 sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-NUTR33 sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-NUTR34 sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-NUTR35 sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-NUTR36 sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-NUTR37 sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-NUTR38 sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-NUTR39 sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-NUTR40 sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-NUTR41 sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-NUTR42 sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-NUTR43 sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-NUTR44 sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-NUTR45 sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-NUTR46 sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-NUTR47 sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-NUTR48 sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-NUTR49 sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-NUTR50 sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-RC sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-ST sy-vline
WA_FRMLS_DYNP_STD_SUB_STR-CT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.