ABAP Select data from SAP table FSCDINFCO_V001_SEND into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP FSCDINFCO_V001_SEND table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FSCDINFCO_V001_SEND. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the FSCDINFCO_V001_SEND table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_FSCDINFCO_V001_SEND TYPE STANDARD TABLE OF FSCDINFCO_V001_SEND, WA_FSCDINFCO_V001_SEND TYPE FSCDINFCO_V001_SEND, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <FSCDINFCO_V001_SEND> TYPE FSCDINFCO_V001_SEND. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_FSCDINFCO_V001_SEND. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM FSCDINFCO_V001_SEND INTO TABLE IT_FSCDINFCO_V001_SEND. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM FSCDINFCO_V001_SEND * INTO TABLE @DATA(IT_FSCDINFCO_V001_SEND2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_FSCDINFCO_V001_SEND INDEX 1 INTO DATA(WA_FSCDINFCO_V001_SEND2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_FSCDINFCO_V001_SEND ASSIGNING <FSCDINFCO_V001_SEND>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<FSCDINFCO_V001_SEND>-INFCO = 1.
<FSCDINFCO_V001_SEND>-INFCOKEY = 1.
<FSCDINFCO_V001_SEND>-RECEIVER = 1.
<FSCDINFCO_V001_SEND>-INFCOTYPE = 1.
<FSCDINFCO_V001_SEND>-GPART = 1.
ENDLOOP. LOOP AT IT_FSCDINFCO_V001_SEND INTO WA_FSCDINFCO_V001_SEND. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_FSCDINFCO_V001_SEND-VKONT, sy-vline,
WA_FSCDINFCO_V001_SEND-VTREF, sy-vline,
WA_FSCDINFCO_V001_SEND-SUBAP, sy-vline,
WA_FSCDINFCO_V001_SEND-CRDATE, sy-vline,
WA_FSCDINFCO_V001_SEND-CRTIME, sy-vline,
WA_FSCDINFCO_V001_SEND-LAUFD, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FSCDINFCO_V001_SEND you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FSCDINFCO_V001_SEND TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FSCDINFCO_V001_SEND INTO WA_FSCDINFCO_V001_SEND. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field GPART CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FSCDINFCO_V001_SEND-GPART IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FSCDINFCO_V001_SEND-GPART.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field VKONT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FSCDINFCO_V001_SEND-VKONT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FSCDINFCO_V001_SEND-VKONT.
WRITE:/ 'New Value:', ld_input.
*Conversion exit ALPHA, internal->external for field VTREF CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FSCDINFCO_V001_SEND-VTREF IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FSCDINFCO_V001_SEND-VTREF.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FSCDINFCO_V001_SEND_STR,
INFCO TYPE STRING,
INFCOKEY TYPE STRING,
RECEIVER TYPE STRING,
INFCOTYPE TYPE STRING,
GPART TYPE STRING,
VKONT TYPE STRING,
VTREF TYPE STRING,
SUBAP TYPE STRING,
CRDATE TYPE STRING,
CRTIME TYPE STRING,
LAUFD TYPE STRING,
LAUFI TYPE STRING,
MAZAE TYPE STRING,
MAHNV TYPE STRING,
MAHNS TYPE STRING,
WAERS TYPE STRING,
MSALM TYPE STRING,
MGE1M TYPE STRING,
MGE2M TYPE STRING,
MGE3M TYPE STRING,
MINTM TYPE STRING,
MVLNR TYPE STRING,
MVSTA TYPE STRING,
PM0_AWKEY TYPE STRING,
PM0_FAEDN TYPE STRING,
PM0_FAEVON TYPE STRING,
PM0_FAEBIS TYPE STRING,
PM0_MVVON TYPE STRING,
PM0_ACTYP TYPE STRING,
PM0_AUGDT TYPE STRING,
PM0_AUSDT TYPE STRING,
PM0_INFCO_V001_TAB TYPE STRING,
PM0_BUDAT TYPE STRING,END OF T_EKKO_STR. DATA: WA_FSCDINFCO_V001_SEND_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FSCDINFCO_V001_SEND_STR-INFCO sy-vline
WA_FSCDINFCO_V001_SEND_STR-INFCOKEY sy-vline
WA_FSCDINFCO_V001_SEND_STR-RECEIVER sy-vline
WA_FSCDINFCO_V001_SEND_STR-INFCOTYPE sy-vline
WA_FSCDINFCO_V001_SEND_STR-GPART sy-vline
WA_FSCDINFCO_V001_SEND_STR-VKONT sy-vline
WA_FSCDINFCO_V001_SEND_STR-VTREF sy-vline
WA_FSCDINFCO_V001_SEND_STR-SUBAP sy-vline
WA_FSCDINFCO_V001_SEND_STR-CRDATE sy-vline
WA_FSCDINFCO_V001_SEND_STR-CRTIME sy-vline
WA_FSCDINFCO_V001_SEND_STR-LAUFD sy-vline
WA_FSCDINFCO_V001_SEND_STR-LAUFI sy-vline
WA_FSCDINFCO_V001_SEND_STR-MAZAE sy-vline
WA_FSCDINFCO_V001_SEND_STR-MAHNV sy-vline
WA_FSCDINFCO_V001_SEND_STR-MAHNS sy-vline
WA_FSCDINFCO_V001_SEND_STR-WAERS sy-vline
WA_FSCDINFCO_V001_SEND_STR-MSALM sy-vline
WA_FSCDINFCO_V001_SEND_STR-MGE1M sy-vline
WA_FSCDINFCO_V001_SEND_STR-MGE2M sy-vline
WA_FSCDINFCO_V001_SEND_STR-MGE3M sy-vline
WA_FSCDINFCO_V001_SEND_STR-MINTM sy-vline
WA_FSCDINFCO_V001_SEND_STR-MVLNR sy-vline
WA_FSCDINFCO_V001_SEND_STR-MVSTA sy-vline
WA_FSCDINFCO_V001_SEND_STR-PM0_AWKEY sy-vline
WA_FSCDINFCO_V001_SEND_STR-PM0_FAEDN sy-vline
WA_FSCDINFCO_V001_SEND_STR-PM0_FAEVON sy-vline
WA_FSCDINFCO_V001_SEND_STR-PM0_FAEBIS sy-vline
WA_FSCDINFCO_V001_SEND_STR-PM0_MVVON sy-vline
WA_FSCDINFCO_V001_SEND_STR-PM0_ACTYP sy-vline
WA_FSCDINFCO_V001_SEND_STR-PM0_AUGDT sy-vline
WA_FSCDINFCO_V001_SEND_STR-PM0_AUSDT sy-vline
WA_FSCDINFCO_V001_SEND_STR-PM0_INFCO_V001_TAB sy-vline
WA_FSCDINFCO_V001_SEND_STR-PM0_BUDAT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.