ABAP Select data from SAP table FSH_CCR_EKET_DISPLAY into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP FSH_CCR_EKET_DISPLAY table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FSH_CCR_EKET_DISPLAY. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the FSH_CCR_EKET_DISPLAY table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_FSH_CCR_EKET_DISPLAY TYPE STANDARD TABLE OF FSH_CCR_EKET_DISPLAY, WA_FSH_CCR_EKET_DISPLAY TYPE FSH_CCR_EKET_DISPLAY, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <FSH_CCR_EKET_DISPLAY> TYPE FSH_CCR_EKET_DISPLAY. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_FSH_CCR_EKET_DISPLAY. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM FSH_CCR_EKET_DISPLAY INTO TABLE IT_FSH_CCR_EKET_DISPLAY. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM FSH_CCR_EKET_DISPLAY * INTO TABLE @DATA(IT_FSH_CCR_EKET_DISPLAY2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_FSH_CCR_EKET_DISPLAY INDEX 1 INTO DATA(WA_FSH_CCR_EKET_DISPLAY2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_FSH_CCR_EKET_DISPLAY ASSIGNING <FSH_CCR_EKET_DISPLAY>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<FSH_CCR_EKET_DISPLAY>-LIGHT = 1.
<FSH_CCR_EKET_DISPLAY>-EBELN = 1.
<FSH_CCR_EKET_DISPLAY>-EBELP = 1.
<FSH_CCR_EKET_DISPLAY>-ETENR = 1.
<FSH_CCR_EKET_DISPLAY>-MATNR = 1.
ENDLOOP. LOOP AT IT_FSH_CCR_EKET_DISPLAY INTO WA_FSH_CCR_EKET_DISPLAY. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_FSH_CCR_EKET_DISPLAY-WERKS, sy-vline,
WA_FSH_CCR_EKET_DISPLAY-LGORT, sy-vline,
WA_FSH_CCR_EKET_DISPLAY-BSTYP, sy-vline,
WA_FSH_CCR_EKET_DISPLAY-EINDT, sy-vline,
WA_FSH_CCR_EKET_DISPLAY-TOTAL_STOCK, sy-vline,
WA_FSH_CCR_EKET_DISPLAY-FSH_SALLOC_QTY_OLD, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FSH_CCR_EKET_DISPLAY you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FSH_CCR_EKET_DISPLAY TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FSH_CCR_EKET_DISPLAY INTO WA_FSH_CCR_EKET_DISPLAY. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field EBELN CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FSH_CCR_EKET_DISPLAY-EBELN IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FSH_CCR_EKET_DISPLAY-EBELN.
WRITE:/ 'New Value:', ld_input.
*Conversion exit MATN1, internal->external for field MATNR CALL FUNCTION 'CONVERSION_EXIT_MATN1_OUTPUT' EXPORTING input = WA_FSH_CCR_EKET_DISPLAY-MATNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FSH_CCR_EKET_DISPLAY-MATNR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FSH_CCR_EKET_DISPLAY_STR,
LIGHT TYPE STRING,
EBELN TYPE STRING,
EBELP TYPE STRING,
ETENR TYPE STRING,
MATNR TYPE STRING,
WERKS TYPE STRING,
LGORT TYPE STRING,
BSTYP TYPE STRING,
EINDT TYPE STRING,
TOTAL_STOCK TYPE STRING,
FSH_SALLOC_QTY_OLD TYPE STRING,
FSH_SALLOC_QTY_NEW TYPE STRING,
SFSH_ALLOC_QTY TYPE STRING,
REMARK TYPE STRING,END OF T_EKKO_STR. DATA: WA_FSH_CCR_EKET_DISPLAY_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FSH_CCR_EKET_DISPLAY_STR-LIGHT sy-vline
WA_FSH_CCR_EKET_DISPLAY_STR-EBELN sy-vline
WA_FSH_CCR_EKET_DISPLAY_STR-EBELP sy-vline
WA_FSH_CCR_EKET_DISPLAY_STR-ETENR sy-vline
WA_FSH_CCR_EKET_DISPLAY_STR-MATNR sy-vline
WA_FSH_CCR_EKET_DISPLAY_STR-WERKS sy-vline
WA_FSH_CCR_EKET_DISPLAY_STR-LGORT sy-vline
WA_FSH_CCR_EKET_DISPLAY_STR-BSTYP sy-vline
WA_FSH_CCR_EKET_DISPLAY_STR-EINDT sy-vline
WA_FSH_CCR_EKET_DISPLAY_STR-TOTAL_STOCK sy-vline
WA_FSH_CCR_EKET_DISPLAY_STR-FSH_SALLOC_QTY_OLD sy-vline
WA_FSH_CCR_EKET_DISPLAY_STR-FSH_SALLOC_QTY_NEW sy-vline
WA_FSH_CCR_EKET_DISPLAY_STR-SFSH_ALLOC_QTY sy-vline
WA_FSH_CCR_EKET_DISPLAY_STR-REMARK sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.