ABAP Select data from SAP table FWTM_DYNP_0100 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP FWTM_DYNP_0100 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to FWTM_DYNP_0100. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the FWTM_DYNP_0100 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_FWTM_DYNP_0100 TYPE STANDARD TABLE OF FWTM_DYNP_0100,
      WA_FWTM_DYNP_0100 TYPE FWTM_DYNP_0100,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <FWTM_DYNP_0100> TYPE FWTM_DYNP_0100.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_FWTM_DYNP_0100.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM FWTM_DYNP_0100
  INTO TABLE IT_FWTM_DYNP_0100.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM FWTM_DYNP_0100
*  INTO TABLE @DATA(IT_FWTM_DYNP_01002).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_FWTM_DYNP_0100 INDEX 1 INTO DATA(WA_FWTM_DYNP_01002).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_FWTM_DYNP_0100 ASSIGNING <FWTM_DYNP_0100>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<FWTM_DYNP_0100>-RUN_ID = 1.
<FWTM_DYNP_0100>-LTEXT = 1.
<FWTM_DYNP_0100>-STATUS_BUKRS = 1.
<FWTM_DYNP_0100>-TEXT_BUKRS = 1.
<FWTM_DYNP_0100>-CHANGE_BUKRS = 1.
ENDLOOP.

LOOP AT IT_FWTM_DYNP_0100 INTO WA_FWTM_DYNP_0100.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_FWTM_DYNP_0100-DISPLAY_BUKRS, sy-vline,
WA_FWTM_DYNP_0100-PROT_BUKRS, sy-vline,
WA_FWTM_DYNP_0100-DOKU_BUKRS, sy-vline,
WA_FWTM_DYNP_0100-STATUS_MATCH, sy-vline,
WA_FWTM_DYNP_0100-TEXT_MATCH, sy-vline,
WA_FWTM_DYNP_0100-CHANGE_MATCH, sy-vline.
ENDLOOP. *Add any further fields from structure WA_FWTM_DYNP_0100 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_FWTM_DYNP_0100 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_FWTM_DYNP_0100 INTO WA_FWTM_DYNP_0100. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field RUN_ID CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_FWTM_DYNP_0100-RUN_ID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_FWTM_DYNP_0100-RUN_ID.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_FWTM_DYNP_0100_STR,
RUN_ID TYPE STRING,
LTEXT TYPE STRING,
STATUS_BUKRS TYPE STRING,
TEXT_BUKRS TYPE STRING,
CHANGE_BUKRS TYPE STRING,
DISPLAY_BUKRS TYPE STRING,
PROT_BUKRS TYPE STRING,
DOKU_BUKRS TYPE STRING,
STATUS_MATCH TYPE STRING,
TEXT_MATCH TYPE STRING,
CHANGE_MATCH TYPE STRING,
DISPLAY_MATCH TYPE STRING,
PROT_MATCH TYPE STRING,
DOKU_MATCH TYPE STRING,
STATUS_ANALYSE TYPE STRING,
TEXT_ANALYSE TYPE STRING,
EXEC_ANALYSE TYPE STRING,
PROT_ANALYSE TYPE STRING,
DOKU_ANALYSE TYPE STRING,
STATUS_STEER TYPE STRING,
TEXT_STEER TYPE STRING,
CHANGE_STEER TYPE STRING,
DISPLAY_STEER TYPE STRING,
PROT_STEER TYPE STRING,
DOKU_STEER TYPE STRING,
TEXT_TEST TYPE STRING,
STATUS_CUST TYPE STRING,
TEXT_CUST TYPE STRING,
TEST_CUST TYPE STRING,
EXEC_CUST TYPE STRING,
RESET_CUST TYPE STRING,
PROT_CUST TYPE STRING,
DOKU_CUST TYPE STRING,
STATUS_MASTER TYPE STRING,
TEXT_MASTER TYPE STRING,
TEST_MASTER TYPE STRING,
EXEC_MASTER TYPE STRING,
RESET_MASTER TYPE STRING,
PROT_MASTER TYPE STRING,
DOKU_MASTER TYPE STRING,
STATUS_DOCS TYPE STRING,
TEXT_DOCS TYPE STRING,
TEST_DOCS TYPE STRING,
EXEC_DOCS TYPE STRING,
RESET_DOCS TYPE STRING,
PROT_DOCS TYPE STRING,
DOKU_DOCS TYPE STRING,
STATUS_ACTIVATE TYPE STRING,
TEXT_ACTIVATE TYPE STRING,
EXEC_ACTIVATE TYPE STRING,
RESET_ACTIVATE TYPE STRING,
DOKU_ACTIVATE TYPE STRING,
PROT_ACTIVATE TYPE STRING,
TEXT_MAIN TYPE STRING,
PROT_MAIN TYPE STRING,END OF T_EKKO_STR. DATA: WA_FWTM_DYNP_0100_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_FWTM_DYNP_0100_STR-RUN_ID sy-vline
WA_FWTM_DYNP_0100_STR-LTEXT sy-vline
WA_FWTM_DYNP_0100_STR-STATUS_BUKRS sy-vline
WA_FWTM_DYNP_0100_STR-TEXT_BUKRS sy-vline
WA_FWTM_DYNP_0100_STR-CHANGE_BUKRS sy-vline
WA_FWTM_DYNP_0100_STR-DISPLAY_BUKRS sy-vline
WA_FWTM_DYNP_0100_STR-PROT_BUKRS sy-vline
WA_FWTM_DYNP_0100_STR-DOKU_BUKRS sy-vline
WA_FWTM_DYNP_0100_STR-STATUS_MATCH sy-vline
WA_FWTM_DYNP_0100_STR-TEXT_MATCH sy-vline
WA_FWTM_DYNP_0100_STR-CHANGE_MATCH sy-vline
WA_FWTM_DYNP_0100_STR-DISPLAY_MATCH sy-vline
WA_FWTM_DYNP_0100_STR-PROT_MATCH sy-vline
WA_FWTM_DYNP_0100_STR-DOKU_MATCH sy-vline
WA_FWTM_DYNP_0100_STR-STATUS_ANALYSE sy-vline
WA_FWTM_DYNP_0100_STR-TEXT_ANALYSE sy-vline
WA_FWTM_DYNP_0100_STR-EXEC_ANALYSE sy-vline
WA_FWTM_DYNP_0100_STR-PROT_ANALYSE sy-vline
WA_FWTM_DYNP_0100_STR-DOKU_ANALYSE sy-vline
WA_FWTM_DYNP_0100_STR-STATUS_STEER sy-vline
WA_FWTM_DYNP_0100_STR-TEXT_STEER sy-vline
WA_FWTM_DYNP_0100_STR-CHANGE_STEER sy-vline
WA_FWTM_DYNP_0100_STR-DISPLAY_STEER sy-vline
WA_FWTM_DYNP_0100_STR-PROT_STEER sy-vline
WA_FWTM_DYNP_0100_STR-DOKU_STEER sy-vline
WA_FWTM_DYNP_0100_STR-TEXT_TEST sy-vline
WA_FWTM_DYNP_0100_STR-STATUS_CUST sy-vline
WA_FWTM_DYNP_0100_STR-TEXT_CUST sy-vline
WA_FWTM_DYNP_0100_STR-TEST_CUST sy-vline
WA_FWTM_DYNP_0100_STR-EXEC_CUST sy-vline
WA_FWTM_DYNP_0100_STR-RESET_CUST sy-vline
WA_FWTM_DYNP_0100_STR-PROT_CUST sy-vline
WA_FWTM_DYNP_0100_STR-DOKU_CUST sy-vline
WA_FWTM_DYNP_0100_STR-STATUS_MASTER sy-vline
WA_FWTM_DYNP_0100_STR-TEXT_MASTER sy-vline
WA_FWTM_DYNP_0100_STR-TEST_MASTER sy-vline
WA_FWTM_DYNP_0100_STR-EXEC_MASTER sy-vline
WA_FWTM_DYNP_0100_STR-RESET_MASTER sy-vline
WA_FWTM_DYNP_0100_STR-PROT_MASTER sy-vline
WA_FWTM_DYNP_0100_STR-DOKU_MASTER sy-vline
WA_FWTM_DYNP_0100_STR-STATUS_DOCS sy-vline
WA_FWTM_DYNP_0100_STR-TEXT_DOCS sy-vline
WA_FWTM_DYNP_0100_STR-TEST_DOCS sy-vline
WA_FWTM_DYNP_0100_STR-EXEC_DOCS sy-vline
WA_FWTM_DYNP_0100_STR-RESET_DOCS sy-vline
WA_FWTM_DYNP_0100_STR-PROT_DOCS sy-vline
WA_FWTM_DYNP_0100_STR-DOKU_DOCS sy-vline
WA_FWTM_DYNP_0100_STR-STATUS_ACTIVATE sy-vline
WA_FWTM_DYNP_0100_STR-TEXT_ACTIVATE sy-vline
WA_FWTM_DYNP_0100_STR-EXEC_ACTIVATE sy-vline
WA_FWTM_DYNP_0100_STR-RESET_ACTIVATE sy-vline
WA_FWTM_DYNP_0100_STR-DOKU_ACTIVATE sy-vline
WA_FWTM_DYNP_0100_STR-PROT_ACTIVATE sy-vline
WA_FWTM_DYNP_0100_STR-TEXT_MAIN sy-vline
WA_FWTM_DYNP_0100_STR-PROT_MAIN sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.