ABAP Select data from SAP table GHO_S_FC_PROJECT_NODE_DATA_SP into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP GHO_S_FC_PROJECT_NODE_DATA_SP table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to GHO_S_FC_PROJECT_NODE_DATA_SP. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the GHO_S_FC_PROJECT_NODE_DATA_SP table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_GHO_S_FC_PROJECT_NODE_DATA_SP TYPE STANDARD TABLE OF GHO_S_FC_PROJECT_NODE_DATA_SP, WA_GHO_S_FC_PROJECT_NODE_DATA_SP TYPE GHO_S_FC_PROJECT_NODE_DATA_SP, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <GHO_S_FC_PROJECT_NODE_DATA_SP> TYPE GHO_S_FC_PROJECT_NODE_DATA_SP. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_GHO_S_FC_PROJECT_NODE_DATA_SP. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM GHO_S_FC_PROJECT_NODE_DATA_SP INTO TABLE IT_GHO_S_FC_PROJECT_NODE_DATA_SP. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM GHO_S_FC_PROJECT_NODE_DATA_SP * INTO TABLE @DATA(IT_GHO_S_FC_PROJECT_NODE_DATA_SP2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_GHO_S_FC_PROJECT_NODE_DATA_SP INDEX 1 INTO DATA(WA_GHO_S_FC_PROJECT_NODE_DATA_SP2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_GHO_S_FC_PROJECT_NODE_DATA_SP ASSIGNING <GHO_S_FC_PROJECT_NODE_DATA_SP>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<GHO_S_FC_PROJECT_NODE_DATA_SP>-PROJECT_ID = 1.
<GHO_S_FC_PROJECT_NODE_DATA_SP>-PROJECT_NAME = 1.
<GHO_S_FC_PROJECT_NODE_DATA_SP>-FORECAST_TYPE = 1.
<GHO_S_FC_PROJECT_NODE_DATA_SP>-FORECAST_DATE = 1.
<GHO_S_FC_PROJECT_NODE_DATA_SP>-EFF_DATE_FROM = 1.
ENDLOOP. LOOP AT IT_GHO_S_FC_PROJECT_NODE_DATA_SP INTO WA_GHO_S_FC_PROJECT_NODE_DATA_SP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_GHO_S_FC_PROJECT_NODE_DATA_SP-EFF_DATE_TO, sy-vline,
WA_GHO_S_FC_PROJECT_NODE_DATA_SP-STATUS_PROFILE, sy-vline,
WA_GHO_S_FC_PROJECT_NODE_DATA_SP-PROFILE_ID, sy-vline,
WA_GHO_S_FC_PROJECT_NODE_DATA_SP-PROJECT_DESCRIPTION, sy-vline,
WA_GHO_S_FC_PROJECT_NODE_DATA_SP-FREQUENCY_CODE, sy-vline,
WA_GHO_S_FC_PROJECT_NODE_DATA_SP-TIME_ZONE, sy-vline.
ENDLOOP. *Add any further fields from structure WA_GHO_S_FC_PROJECT_NODE_DATA_SP you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_GHO_S_FC_PROJECT_NODE_DATA_SP TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_GHO_S_FC_PROJECT_NODE_DATA_SP INTO WA_GHO_S_FC_PROJECT_NODE_DATA_SP. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_GHO_S_FC_PROJECT_NODE_DATA_SP_STR,
PROJECT_ID TYPE STRING,
PROJECT_NAME TYPE STRING,
FORECAST_TYPE TYPE STRING,
FORECAST_DATE TYPE STRING,
EFF_DATE_FROM TYPE STRING,
EFF_DATE_TO TYPE STRING,
STATUS_PROFILE TYPE STRING,
PROFILE_ID TYPE STRING,
PROJECT_DESCRIPTION TYPE STRING,
FREQUENCY_CODE TYPE STRING,
TIME_ZONE TYPE STRING,
STATUS_OBJECT_NO TYPE STRING,
FC_USER_GROUP_ID TYPE STRING,
DESCRIPT TYPE STRING,
STAKEHOLDER_GROUP_ID TYPE STRING,
CREATED_BY TYPE STRING,
CREATED_TST TYPE STRING,
CHANGED_BY TYPE STRING,
CHANGED_TST TYPE STRING,
BASIS_ID TYPE STRING,
STATUS_CODE TYPE STRING,
STATUS_TEXT TYPE STRING,
BASIS_DESC TYPE STRING,
FREQUENCY_DESC TYPE STRING,
FORECAST_TYPE_DESCRIPTION TYPE STRING,
IS_PROJECT_SETUP_INITIATED TYPE STRING,
IS_SUBMITTED TYPE STRING,
IS_GD_READY TYPE STRING,
IS_GD_INITIATED TYPE STRING,
PROJECT_COPIED_FROM TYPE STRING,
IS_PROJECT_SUBMITABLE TYPE STRING,
IS_LOCKED TYPE STRING,
IS_COPY_IN_PROGRESS TYPE STRING,
TIME_ZONE_DESCRIPT TYPE STRING,END OF T_EKKO_STR. DATA: WA_GHO_S_FC_PROJECT_NODE_DATA_SP_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_GHO_S_FC_PROJECT_NODE_DATA_SP_STR-PROJECT_ID sy-vline
WA_GHO_S_FC_PROJECT_NODE_DATA_SP_STR-PROJECT_NAME sy-vline
WA_GHO_S_FC_PROJECT_NODE_DATA_SP_STR-FORECAST_TYPE sy-vline
WA_GHO_S_FC_PROJECT_NODE_DATA_SP_STR-FORECAST_DATE sy-vline
WA_GHO_S_FC_PROJECT_NODE_DATA_SP_STR-EFF_DATE_FROM sy-vline
WA_GHO_S_FC_PROJECT_NODE_DATA_SP_STR-EFF_DATE_TO sy-vline
WA_GHO_S_FC_PROJECT_NODE_DATA_SP_STR-STATUS_PROFILE sy-vline
WA_GHO_S_FC_PROJECT_NODE_DATA_SP_STR-PROFILE_ID sy-vline
WA_GHO_S_FC_PROJECT_NODE_DATA_SP_STR-PROJECT_DESCRIPTION sy-vline
WA_GHO_S_FC_PROJECT_NODE_DATA_SP_STR-FREQUENCY_CODE sy-vline
WA_GHO_S_FC_PROJECT_NODE_DATA_SP_STR-TIME_ZONE sy-vline
WA_GHO_S_FC_PROJECT_NODE_DATA_SP_STR-STATUS_OBJECT_NO sy-vline
WA_GHO_S_FC_PROJECT_NODE_DATA_SP_STR-FC_USER_GROUP_ID sy-vline
WA_GHO_S_FC_PROJECT_NODE_DATA_SP_STR-DESCRIPT sy-vline
WA_GHO_S_FC_PROJECT_NODE_DATA_SP_STR-STAKEHOLDER_GROUP_ID sy-vline
WA_GHO_S_FC_PROJECT_NODE_DATA_SP_STR-CREATED_BY sy-vline
WA_GHO_S_FC_PROJECT_NODE_DATA_SP_STR-CREATED_TST sy-vline
WA_GHO_S_FC_PROJECT_NODE_DATA_SP_STR-CHANGED_BY sy-vline
WA_GHO_S_FC_PROJECT_NODE_DATA_SP_STR-CHANGED_TST sy-vline
WA_GHO_S_FC_PROJECT_NODE_DATA_SP_STR-BASIS_ID sy-vline
WA_GHO_S_FC_PROJECT_NODE_DATA_SP_STR-STATUS_CODE sy-vline
WA_GHO_S_FC_PROJECT_NODE_DATA_SP_STR-STATUS_TEXT sy-vline
WA_GHO_S_FC_PROJECT_NODE_DATA_SP_STR-BASIS_DESC sy-vline
WA_GHO_S_FC_PROJECT_NODE_DATA_SP_STR-FREQUENCY_DESC sy-vline
WA_GHO_S_FC_PROJECT_NODE_DATA_SP_STR-FORECAST_TYPE_DESCRIPTION sy-vline
WA_GHO_S_FC_PROJECT_NODE_DATA_SP_STR-IS_PROJECT_SETUP_INITIATED sy-vline
WA_GHO_S_FC_PROJECT_NODE_DATA_SP_STR-IS_SUBMITTED sy-vline
WA_GHO_S_FC_PROJECT_NODE_DATA_SP_STR-IS_GD_READY sy-vline
WA_GHO_S_FC_PROJECT_NODE_DATA_SP_STR-IS_GD_INITIATED sy-vline
WA_GHO_S_FC_PROJECT_NODE_DATA_SP_STR-PROJECT_COPIED_FROM sy-vline
WA_GHO_S_FC_PROJECT_NODE_DATA_SP_STR-IS_PROJECT_SUBMITABLE sy-vline
WA_GHO_S_FC_PROJECT_NODE_DATA_SP_STR-IS_LOCKED sy-vline
WA_GHO_S_FC_PROJECT_NODE_DATA_SP_STR-IS_COPY_IN_PROGRESS sy-vline
WA_GHO_S_FC_PROJECT_NODE_DATA_SP_STR-TIME_ZONE_DESCRIPT sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.