ABAP Select data from SAP table GHO_S_MP_FDCPN_WORKLIST_ORD into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP GHO_S_MP_FDCPN_WORKLIST_ORD table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to GHO_S_MP_FDCPN_WORKLIST_ORD. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the GHO_S_MP_FDCPN_WORKLIST_ORD table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_GHO_S_MP_FDCPN_WORKLIST_ORD TYPE STANDARD TABLE OF GHO_S_MP_FDCPN_WORKLIST_ORD, WA_GHO_S_MP_FDCPN_WORKLIST_ORD TYPE GHO_S_MP_FDCPN_WORKLIST_ORD, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <GHO_S_MP_FDCPN_WORKLIST_ORD> TYPE GHO_S_MP_FDCPN_WORKLIST_ORD. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_GHO_S_MP_FDCPN_WORKLIST_ORD. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM GHO_S_MP_FDCPN_WORKLIST_ORD INTO TABLE IT_GHO_S_MP_FDCPN_WORKLIST_ORD. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM GHO_S_MP_FDCPN_WORKLIST_ORD * INTO TABLE @DATA(IT_GHO_S_MP_FDCPN_WORKLIST_ORD2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_GHO_S_MP_FDCPN_WORKLIST_ORD INDEX 1 INTO DATA(WA_GHO_S_MP_FDCPN_WORKLIST_ORD2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_GHO_S_MP_FDCPN_WORKLIST_ORD ASSIGNING <GHO_S_MP_FDCPN_WORKLIST_ORD>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<GHO_S_MP_FDCPN_WORKLIST_ORD>-GHO_NET_ID = 1.
<GHO_S_MP_FDCPN_WORKLIST_ORD>-GHO_NET_OBJ_ID = 1.
<GHO_S_MP_FDCPN_WORKLIST_ORD>-GHO_NET_OBJ_TYPE = 1.
<GHO_S_MP_FDCPN_WORKLIST_ORD>-MEAS_DATE_FROM = 1.
<GHO_S_MP_FDCPN_WORKLIST_ORD>-EXISTENCE_FLAG = 1.
ENDLOOP. LOOP AT IT_GHO_S_MP_FDCPN_WORKLIST_ORD INTO WA_GHO_S_MP_FDCPN_WORKLIST_ORD. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_GHO_S_MP_FDCPN_WORKLIST_ORD-FIELDDATA, sy-vline,
WA_GHO_S_MP_FDCPN_WORKLIST_ORD-GHO_NET_OBJ_ID_DESC, sy-vline,
WA_GHO_S_MP_FDCPN_WORKLIST_ORD-GHO_NET_OBJ_TYPE_DESC, sy-vline,
WA_GHO_S_MP_FDCPN_WORKLIST_ORD-GHO_FREQUENCY, sy-vline,
WA_GHO_S_MP_FDCPN_WORKLIST_ORD-MEAS_TIME_FROM, sy-vline,
WA_GHO_S_MP_FDCPN_WORKLIST_ORD-MEAS_DATE_TO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_GHO_S_MP_FDCPN_WORKLIST_ORD you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_GHO_S_MP_FDCPN_WORKLIST_ORD TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_GHO_S_MP_FDCPN_WORKLIST_ORD INTO WA_GHO_S_MP_FDCPN_WORKLIST_ORD. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit TPLNR, internal->external for field NETID CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_GHO_S_MP_FDCPN_WORKLIST_ORD-NETID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_MP_FDCPN_WORKLIST_ORD-NETID.
WRITE:/ 'New Value:', ld_input.
*Conversion exit TPLNR, internal->external for field OBJID CALL FUNCTION 'CONVERSION_EXIT_TPLNR_OUTPUT' EXPORTING input = WA_GHO_S_MP_FDCPN_WORKLIST_ORD-OBJID IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_MP_FDCPN_WORKLIST_ORD-OBJID.
WRITE:/ 'New Value:', ld_input.
*Conversion exit GHONO, internal->external for field ORIGINATING_MP CALL FUNCTION 'CONVERSION_EXIT_GHONO_OUTPUT' EXPORTING input = WA_GHO_S_MP_FDCPN_WORKLIST_ORD-ORIGINATING_MP IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GHO_S_MP_FDCPN_WORKLIST_ORD-ORIGINATING_MP.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_GHO_S_MP_FDCPN_WORKLIST_ORD_STR,
GHO_NET_ID TYPE STRING,
GHO_NET_OBJ_ID TYPE STRING,
GHO_NET_OBJ_TYPE TYPE STRING,
MEAS_DATE_FROM TYPE STRING,
EXISTENCE_FLAG TYPE STRING,
FIELDDATA TYPE STRING,
GHO_NET_OBJ_ID_DESC TYPE STRING,
GHO_NET_OBJ_TYPE_DESC TYPE STRING,
GHO_FREQUENCY TYPE STRING,
MEAS_TIME_FROM TYPE STRING,
MEAS_DATE_TO TYPE STRING,
MEAS_TIME_TO TYPE STRING,
MSMT_STARTDATE TYPE STRING,
MSMT_ENDDATE TYPE STRING,
FIELDDATA_DESC TYPE STRING,
DATE_PICK_OPT TYPE STRING,
NODRES TYPE STRING,
ADDL_STARTDATE TYPE STRING,
ADDL_ENDDATE TYPE STRING,
NET_ID_TIMEZONE TYPE STRING,
FD_KEY TYPE STRING,
ADDNL_KEY TYPE STRING,
NETID TYPE STRING,
OBJID TYPE STRING,
AUTH_FLAG TYPE STRING,
PS_FILTER TYPE STRING,
REC_COUNT TYPE STRING,
MEAS_CAT_ID TYPE STRING,
MEAS_CAT_ID_DESC TYPE STRING,
QUANTITY_TYPE TYPE STRING,
ORIGINATING_MP TYPE STRING,END OF T_EKKO_STR. DATA: WA_GHO_S_MP_FDCPN_WORKLIST_ORD_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_GHO_S_MP_FDCPN_WORKLIST_ORD_STR-GHO_NET_ID sy-vline
WA_GHO_S_MP_FDCPN_WORKLIST_ORD_STR-GHO_NET_OBJ_ID sy-vline
WA_GHO_S_MP_FDCPN_WORKLIST_ORD_STR-GHO_NET_OBJ_TYPE sy-vline
WA_GHO_S_MP_FDCPN_WORKLIST_ORD_STR-MEAS_DATE_FROM sy-vline
WA_GHO_S_MP_FDCPN_WORKLIST_ORD_STR-EXISTENCE_FLAG sy-vline
WA_GHO_S_MP_FDCPN_WORKLIST_ORD_STR-FIELDDATA sy-vline
WA_GHO_S_MP_FDCPN_WORKLIST_ORD_STR-GHO_NET_OBJ_ID_DESC sy-vline
WA_GHO_S_MP_FDCPN_WORKLIST_ORD_STR-GHO_NET_OBJ_TYPE_DESC sy-vline
WA_GHO_S_MP_FDCPN_WORKLIST_ORD_STR-GHO_FREQUENCY sy-vline
WA_GHO_S_MP_FDCPN_WORKLIST_ORD_STR-MEAS_TIME_FROM sy-vline
WA_GHO_S_MP_FDCPN_WORKLIST_ORD_STR-MEAS_DATE_TO sy-vline
WA_GHO_S_MP_FDCPN_WORKLIST_ORD_STR-MEAS_TIME_TO sy-vline
WA_GHO_S_MP_FDCPN_WORKLIST_ORD_STR-MSMT_STARTDATE sy-vline
WA_GHO_S_MP_FDCPN_WORKLIST_ORD_STR-MSMT_ENDDATE sy-vline
WA_GHO_S_MP_FDCPN_WORKLIST_ORD_STR-FIELDDATA_DESC sy-vline
WA_GHO_S_MP_FDCPN_WORKLIST_ORD_STR-DATE_PICK_OPT sy-vline
WA_GHO_S_MP_FDCPN_WORKLIST_ORD_STR-NODRES sy-vline
WA_GHO_S_MP_FDCPN_WORKLIST_ORD_STR-ADDL_STARTDATE sy-vline
WA_GHO_S_MP_FDCPN_WORKLIST_ORD_STR-ADDL_ENDDATE sy-vline
WA_GHO_S_MP_FDCPN_WORKLIST_ORD_STR-NET_ID_TIMEZONE sy-vline
WA_GHO_S_MP_FDCPN_WORKLIST_ORD_STR-FD_KEY sy-vline
WA_GHO_S_MP_FDCPN_WORKLIST_ORD_STR-ADDNL_KEY sy-vline
WA_GHO_S_MP_FDCPN_WORKLIST_ORD_STR-NETID sy-vline
WA_GHO_S_MP_FDCPN_WORKLIST_ORD_STR-OBJID sy-vline
WA_GHO_S_MP_FDCPN_WORKLIST_ORD_STR-AUTH_FLAG sy-vline
WA_GHO_S_MP_FDCPN_WORKLIST_ORD_STR-PS_FILTER sy-vline
WA_GHO_S_MP_FDCPN_WORKLIST_ORD_STR-REC_COUNT sy-vline
WA_GHO_S_MP_FDCPN_WORKLIST_ORD_STR-MEAS_CAT_ID sy-vline
WA_GHO_S_MP_FDCPN_WORKLIST_ORD_STR-MEAS_CAT_ID_DESC sy-vline
WA_GHO_S_MP_FDCPN_WORKLIST_ORD_STR-QUANTITY_TYPE sy-vline
WA_GHO_S_MP_FDCPN_WORKLIST_ORD_STR-ORIGINATING_MP sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.