ABAP Select data from SAP table GLO_FAA_S_ANX16_XML_HOE350 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP GLO_FAA_S_ANX16_XML_HOE350 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to GLO_FAA_S_ANX16_XML_HOE350. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the GLO_FAA_S_ANX16_XML_HOE350 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_GLO_FAA_S_ANX16_XML_HOE350 TYPE STANDARD TABLE OF GLO_FAA_S_ANX16_XML_HOE350,
      WA_GLO_FAA_S_ANX16_XML_HOE350 TYPE GLO_FAA_S_ANX16_XML_HOE350,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <GLO_FAA_S_ANX16_XML_HOE350> TYPE GLO_FAA_S_ANX16_XML_HOE350.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_GLO_FAA_S_ANX16_XML_HOE350.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM GLO_FAA_S_ANX16_XML_HOE350
  INTO TABLE IT_GLO_FAA_S_ANX16_XML_HOE350.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM GLO_FAA_S_ANX16_XML_HOE350
*  INTO TABLE @DATA(IT_GLO_FAA_S_ANX16_XML_HOE3502).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_GLO_FAA_S_ANX16_XML_HOE350 INDEX 1 INTO DATA(WA_GLO_FAA_S_ANX16_XML_HOE3502).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_GLO_FAA_S_ANX16_XML_HOE350 ASSIGNING <GLO_FAA_S_ANX16_XML_HOE350>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<GLO_FAA_S_ANX16_XML_HOE350>-TXT50 = 1.
<GLO_FAA_S_ANX16_XML_HOE350>-BUP_ST = 1.
<GLO_FAA_S_ANX16_XML_HOE350>-BUP_ST_J_E = 1.
<GLO_FAA_S_ANX16_XML_HOE350>-BUP_ST_J = 1.
<GLO_FAA_S_ANX16_XML_HOE350>-TXT50_IMD = 1.
ENDLOOP.

LOOP AT IT_GLO_FAA_S_ANX16_XML_HOE350 INTO WA_GLO_FAA_S_ANX16_XML_HOE350.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_GLO_FAA_S_ANX16_XML_HOE350-DEP_MNTHS, sy-vline,
WA_GLO_FAA_S_ANX16_XML_HOE350-DEP_MNTHS_CRNTTRM, sy-vline,
WA_GLO_FAA_S_ANX16_XML_HOE350-WAERS, sy-vline,
WA_GLO_FAA_S_ANX16_XML_HOE350-GJE_KANSW, sy-vline,
WA_GLO_FAA_S_ANX16_XML_HOE350-DEP_LIM_NT, sy-vline,
WA_GLO_FAA_S_ANX16_XML_HOE350-DEP_AMT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_GLO_FAA_S_ANX16_XML_HOE350 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_GLO_FAA_S_ANX16_XML_HOE350 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_GLO_FAA_S_ANX16_XML_HOE350 INTO WA_GLO_FAA_S_ANX16_XML_HOE350. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_GLO_FAA_S_ANX16_XML_HOE350_STR,
TXT50 TYPE STRING,
BUP_ST TYPE STRING,
BUP_ST_J_E TYPE STRING,
BUP_ST_J TYPE STRING,
TXT50_IMD TYPE STRING,
DEP_MNTHS TYPE STRING,
DEP_MNTHS_CRNTTRM TYPE STRING,
WAERS TYPE STRING,
GJE_KANSW TYPE STRING,
DEP_LIM_NT TYPE STRING,
DEP_AMT TYPE STRING,
DEP_SHORT TYPE STRING,
DEP_EXCESS TYPE STRING,
DEP_DEF_EX_PR TYPE STRING,
ADM_WO TYPE STRING,
DEP_EX_CO TYPE STRING,
GJE_KANSW_IMD TYPE STRING,
KAFA_IMD TYPE STRING,
DEP_AMT_IMD TYPE STRING,
GJE_BCHWRT_IMD TYPE STRING,END OF T_EKKO_STR. DATA: WA_GLO_FAA_S_ANX16_XML_HOE350_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_GLO_FAA_S_ANX16_XML_HOE350_STR-TXT50 sy-vline
WA_GLO_FAA_S_ANX16_XML_HOE350_STR-BUP_ST sy-vline
WA_GLO_FAA_S_ANX16_XML_HOE350_STR-BUP_ST_J_E sy-vline
WA_GLO_FAA_S_ANX16_XML_HOE350_STR-BUP_ST_J sy-vline
WA_GLO_FAA_S_ANX16_XML_HOE350_STR-TXT50_IMD sy-vline
WA_GLO_FAA_S_ANX16_XML_HOE350_STR-DEP_MNTHS sy-vline
WA_GLO_FAA_S_ANX16_XML_HOE350_STR-DEP_MNTHS_CRNTTRM sy-vline
WA_GLO_FAA_S_ANX16_XML_HOE350_STR-WAERS sy-vline
WA_GLO_FAA_S_ANX16_XML_HOE350_STR-GJE_KANSW sy-vline
WA_GLO_FAA_S_ANX16_XML_HOE350_STR-DEP_LIM_NT sy-vline
WA_GLO_FAA_S_ANX16_XML_HOE350_STR-DEP_AMT sy-vline
WA_GLO_FAA_S_ANX16_XML_HOE350_STR-DEP_SHORT sy-vline
WA_GLO_FAA_S_ANX16_XML_HOE350_STR-DEP_EXCESS sy-vline
WA_GLO_FAA_S_ANX16_XML_HOE350_STR-DEP_DEF_EX_PR sy-vline
WA_GLO_FAA_S_ANX16_XML_HOE350_STR-ADM_WO sy-vline
WA_GLO_FAA_S_ANX16_XML_HOE350_STR-DEP_EX_CO sy-vline
WA_GLO_FAA_S_ANX16_XML_HOE350_STR-GJE_KANSW_IMD sy-vline
WA_GLO_FAA_S_ANX16_XML_HOE350_STR-KAFA_IMD sy-vline
WA_GLO_FAA_S_ANX16_XML_HOE350_STR-DEP_AMT_IMD sy-vline
WA_GLO_FAA_S_ANX16_XML_HOE350_STR-GJE_BCHWRT_IMD sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.