ABAP Select data from SAP table GLSO1 into internal table

Get Example source ABAP code based on a different SAP table
  

Below is a number of ABAP code snippets to demonstrate how to select data from SAP GLSO1 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to GLSO1. See here for more generic Select statement tips.

Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.

There is also a full declaration of the GLSO1 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.

DATA: IT_GLSO1 TYPE STANDARD TABLE OF GLSO1,
      WA_GLSO1 TYPE GLSO1,
      GD_STR TYPE STRING.

DATA: lo_typedescr type REF TO cl_abap_typedescr.
DATA: lv_fieldname type fieldname.

FIELD-SYMBOLS: <FIELD> TYPE any.
FIELD-SYMBOLS: <GLSO1> TYPE GLSO1.

*Process all fields in table header/work area as string values
  PERFORM process_as_string_field_values CHANGING wa_GLSO1.

SELECT *
*restrict ABAP select to first 10 rows
 UP TO 10 ROWS      
  FROM GLSO1
  INTO TABLE IT_GLSO1.

*Select data and declare internal table using in-line method @DATA
*SELECT *
*  FROM GLSO1
*  INTO TABLE @DATA(IT_GLSO12).
*--Further methods of using ABAP code to  select data from SAP database tables

*You can also declare the header/work area using the in-line DATA declaration method
READ TABLE IT_GLSO1 INDEX 1 INTO DATA(WA_GLSO12).


*Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL
LOOP AT IT_GLSO1 ASSIGNING <GLSO1>.
*To update a field value using a field symbol simply change the value via the field symbol pointer
<GLSO1>-RCLNT = 1.
<GLSO1>-RLDNR = 1.
<GLSO1>-RRCTY = 1.
<GLSO1>-RVERS = 1.
<GLSO1>-RYEAR = 1.
ENDLOOP.

LOOP AT IT_GLSO1 INTO WA_GLSO1.
*Write horizonal line to screen report.
  WRITE:/ sy-uline.

*Write selected data to screen/report before conversion.
  WRITE:/ sy-vline,   WA_GLSO1-ROBJNR, sy-vline,
WA_GLSO1-SOBJNR, sy-vline,
WA_GLSO1-OCLNT, sy-vline,
WA_GLSO1-RTCUR, sy-vline,
WA_GLSO1-RUNIT, sy-vline,
WA_GLSO1-DRCRK, sy-vline.
ENDLOOP. *Add any further fields from structure WA_GLSO1 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_GLSO1 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_GLSO1 INTO WA_GLSO1. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.

*Conversion exit ALPHA, internal->external for field RLDNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_GLSO1-RLDNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GLSO1-RLDNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RVERS CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_GLSO1-RVERS IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GLSO1-RVERS.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field RYEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_GLSO1-RYEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GLSO1-RYEAR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field RUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_GLSO1-RUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GLSO1-RUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field DOCNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_GLSO1-DOCNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GLSO1-DOCNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RACCT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_GLSO1-RACCT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GLSO1-RACCT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RASSC CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_GLSO1-RASSC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GLSO1-RASSC.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field RCNTR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_GLSO1-RCNTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GLSO1-RCNTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SACCT CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_GLSO1-SACCT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GLSO1-SACCT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SASSC CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_GLSO1-SASSC IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GLSO1-SASSC.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field SCNTR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_GLSO1-SCNTR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GLSO1-SCNTR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field TSL CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_GLSO1-TSL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GLSO1-TSL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field HSL CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_GLSO1-HSL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GLSO1-HSL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit AC172, internal->external for field KSL CALL FUNCTION 'CONVERSION_EXIT_AC172_OUTPUT' EXPORTING input = WA_GLSO1-KSL IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GLSO1-KSL.
WRITE:/ 'New Value:', ld_input.

*Conversion exit CUNIT, internal->external for field AUNIT CALL FUNCTION 'CONVERSION_EXIT_CUNIT_OUTPUT' EXPORTING input = WA_GLSO1-AUNIT IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GLSO1-AUNIT.
WRITE:/ 'New Value:', ld_input.

*Conversion exit ALPHA, internal->external for field REFDOCNR CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_GLSO1-REFDOCNR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GLSO1-REFDOCNR.
WRITE:/ 'New Value:', ld_input.

*Conversion exit GJAHR, internal->external for field REFRYEAR CALL FUNCTION 'CONVERSION_EXIT_GJAHR_OUTPUT' EXPORTING input = WA_GLSO1-REFRYEAR IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GLSO1-REFRYEAR.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_GLSO1_STR,
RCLNT TYPE STRING,
RLDNR TYPE STRING,
RRCTY TYPE STRING,
RVERS TYPE STRING,
RYEAR TYPE STRING,
ROBJNR TYPE STRING,
SOBJNR TYPE STRING,
OCLNT TYPE STRING,
RTCUR TYPE STRING,
RUNIT TYPE STRING,
DRCRK TYPE STRING,
POPER TYPE STRING,
DOCCT TYPE STRING,
DOCNR TYPE STRING,
DOCLN TYPE STRING,
RBUKRS TYPE STRING,
RACCT TYPE STRING,
RBUSA TYPE STRING,
RUMSKZ TYPE STRING,
RMVCT TYPE STRING,
RASSC TYPE STRING,
RKOKRS TYPE STRING,
RCNTR TYPE STRING,
RACVT TYPE STRING,
SBUKRS TYPE STRING,
SACCT TYPE STRING,
SBUSA TYPE STRING,
SUMSKZ TYPE STRING,
SMVCT TYPE STRING,
SASSC TYPE STRING,
SKOKRS TYPE STRING,
SCNTR TYPE STRING,
SACVT TYPE STRING,
TSL TYPE STRING,
HSL TYPE STRING,
KSL TYPE STRING,
MSL TYPE STRING,
ASL TYPE STRING,
AUNIT TYPE STRING,
SGTXT TYPE STRING,
AUTOM TYPE STRING,
DOCTY TYPE STRING,
ACTIV TYPE STRING,
BVORG TYPE STRING,
BUDAT TYPE STRING,
WSDAT TYPE STRING,
REFDOCNR TYPE STRING,
REFRYEAR TYPE STRING,
REFDOCLN TYPE STRING,
REFDOCCT TYPE STRING,
REFACTIV TYPE STRING,
CPUDT TYPE STRING,
CPUTM TYPE STRING,
USNAM TYPE STRING,END OF T_EKKO_STR. DATA: WA_GLSO1_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_GLSO1_STR-RCLNT sy-vline
WA_GLSO1_STR-RLDNR sy-vline
WA_GLSO1_STR-RRCTY sy-vline
WA_GLSO1_STR-RVERS sy-vline
WA_GLSO1_STR-RYEAR sy-vline
WA_GLSO1_STR-ROBJNR sy-vline
WA_GLSO1_STR-SOBJNR sy-vline
WA_GLSO1_STR-OCLNT sy-vline
WA_GLSO1_STR-RTCUR sy-vline
WA_GLSO1_STR-RUNIT sy-vline
WA_GLSO1_STR-DRCRK sy-vline
WA_GLSO1_STR-POPER sy-vline
WA_GLSO1_STR-DOCCT sy-vline
WA_GLSO1_STR-DOCNR sy-vline
WA_GLSO1_STR-DOCLN sy-vline
WA_GLSO1_STR-RBUKRS sy-vline
WA_GLSO1_STR-RACCT sy-vline
WA_GLSO1_STR-RBUSA sy-vline
WA_GLSO1_STR-RUMSKZ sy-vline
WA_GLSO1_STR-RMVCT sy-vline
WA_GLSO1_STR-RASSC sy-vline
WA_GLSO1_STR-RKOKRS sy-vline
WA_GLSO1_STR-RCNTR sy-vline
WA_GLSO1_STR-RACVT sy-vline
WA_GLSO1_STR-SBUKRS sy-vline
WA_GLSO1_STR-SACCT sy-vline
WA_GLSO1_STR-SBUSA sy-vline
WA_GLSO1_STR-SUMSKZ sy-vline
WA_GLSO1_STR-SMVCT sy-vline
WA_GLSO1_STR-SASSC sy-vline
WA_GLSO1_STR-SKOKRS sy-vline
WA_GLSO1_STR-SCNTR sy-vline
WA_GLSO1_STR-SACVT sy-vline
WA_GLSO1_STR-TSL sy-vline
WA_GLSO1_STR-HSL sy-vline
WA_GLSO1_STR-KSL sy-vline
WA_GLSO1_STR-MSL sy-vline
WA_GLSO1_STR-ASL sy-vline
WA_GLSO1_STR-AUNIT sy-vline
WA_GLSO1_STR-SGTXT sy-vline
WA_GLSO1_STR-AUTOM sy-vline
WA_GLSO1_STR-DOCTY sy-vline
WA_GLSO1_STR-ACTIV sy-vline
WA_GLSO1_STR-BVORG sy-vline
WA_GLSO1_STR-BUDAT sy-vline
WA_GLSO1_STR-WSDAT sy-vline
WA_GLSO1_STR-REFDOCNR sy-vline
WA_GLSO1_STR-REFRYEAR sy-vline
WA_GLSO1_STR-REFDOCLN sy-vline
WA_GLSO1_STR-REFDOCCT sy-vline
WA_GLSO1_STR-REFACTIV sy-vline
WA_GLSO1_STR-CPUDT sy-vline
WA_GLSO1_STR-CPUTM sy-vline
WA_GLSO1_STR-USNAM sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.