ABAP Select data from SAP table GRPC_S_PC_DAB_M3 into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP GRPC_S_PC_DAB_M3 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to GRPC_S_PC_DAB_M3. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the GRPC_S_PC_DAB_M3 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_GRPC_S_PC_DAB_M3 TYPE STANDARD TABLE OF GRPC_S_PC_DAB_M3, WA_GRPC_S_PC_DAB_M3 TYPE GRPC_S_PC_DAB_M3, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <GRPC_S_PC_DAB_M3> TYPE GRPC_S_PC_DAB_M3. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_GRPC_S_PC_DAB_M3. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM GRPC_S_PC_DAB_M3 INTO TABLE IT_GRPC_S_PC_DAB_M3. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM GRPC_S_PC_DAB_M3 * INTO TABLE @DATA(IT_GRPC_S_PC_DAB_M32). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_GRPC_S_PC_DAB_M3 INDEX 1 INTO DATA(WA_GRPC_S_PC_DAB_M32). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_GRPC_S_PC_DAB_M3 ASSIGNING <GRPC_S_PC_DAB_M3>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<GRPC_S_PC_DAB_M3>-RE = 1.
<GRPC_S_PC_DAB_M3>-RE_T = 1.
<GRPC_S_PC_DAB_M3>-OU = 1.
<GRPC_S_PC_DAB_M3>-OU_T = 1.
<GRPC_S_PC_DAB_M3>-OU_D = 1.
ENDLOOP. LOOP AT IT_GRPC_S_PC_DAB_M3 INTO WA_GRPC_S_PC_DAB_M3. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_GRPC_S_PC_DAB_M3-OU_COUNTRY, sy-vline,
WA_GRPC_S_PC_DAB_M3-OU_COUNTRY_T, sy-vline,
WA_GRPC_S_PC_DAB_M3-OU_REGION, sy-vline,
WA_GRPC_S_PC_DAB_M3-OU_REGION_T, sy-vline,
WA_GRPC_S_PC_DAB_M3-OU_IN_SCOPE, sy-vline,
WA_GRPC_S_PC_DAB_M3-OU_IN_SCOPE_T, sy-vline.
ENDLOOP. *Add any further fields from structure WA_GRPC_S_PC_DAB_M3 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_GRPC_S_PC_DAB_M3 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_GRPC_S_PC_DAB_M3 INTO WA_GRPC_S_PC_DAB_M3. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_GRPC_S_PC_DAB_M3_STR,
RE TYPE STRING,
RE_T TYPE STRING,
OU TYPE STRING,
OU_T TYPE STRING,
OU_D TYPE STRING,
OU_COUNTRY TYPE STRING,
OU_COUNTRY_T TYPE STRING,
OU_REGION TYPE STRING,
OU_REGION_T TYPE STRING,
OU_IN_SCOPE TYPE STRING,
OU_IN_SCOPE_T TYPE STRING,
PR TYPE STRING,
PR_T TYPE STRING,
SP TYPE STRING,
SP_T TYPE STRING,
CN TYPE STRING,
CN_T TYPE STRING,
CN_SIG TYPE STRING,
CN_SIG_T TYPE STRING,
CN_EVIDENCE TYPE STRING,
CN_EVIDENCE_T TYPE STRING,
CN_CNTR_RISK TYPE STRING,
CN_CNTR_RISK_T TYPE STRING,
CN_TSTAUT TYPE STRING,
CN_TSTAUT_T TYPE STRING,
CD_RATING TYPE STRING,
CD_RATING_T TYPE STRING,
CD_DUE_DATE TYPE STRING,
CD_STATUS TYPE STRING,
CE_RATING TYPE STRING,
CE_RATING_T TYPE STRING,
CE_DUE_DATE TYPE STRING,
CE_STATUS TYPE STRING,
TE_RATING TYPE STRING,
TE_RATING_T TYPE STRING,
TE_DUE_DATE TYPE STRING,
TE_STATUS TYPE STRING,
RATING TYPE STRING,
RATING_T TYPE STRING,END OF T_EKKO_STR. DATA: WA_GRPC_S_PC_DAB_M3_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_GRPC_S_PC_DAB_M3_STR-RE sy-vline
WA_GRPC_S_PC_DAB_M3_STR-RE_T sy-vline
WA_GRPC_S_PC_DAB_M3_STR-OU sy-vline
WA_GRPC_S_PC_DAB_M3_STR-OU_T sy-vline
WA_GRPC_S_PC_DAB_M3_STR-OU_D sy-vline
WA_GRPC_S_PC_DAB_M3_STR-OU_COUNTRY sy-vline
WA_GRPC_S_PC_DAB_M3_STR-OU_COUNTRY_T sy-vline
WA_GRPC_S_PC_DAB_M3_STR-OU_REGION sy-vline
WA_GRPC_S_PC_DAB_M3_STR-OU_REGION_T sy-vline
WA_GRPC_S_PC_DAB_M3_STR-OU_IN_SCOPE sy-vline
WA_GRPC_S_PC_DAB_M3_STR-OU_IN_SCOPE_T sy-vline
WA_GRPC_S_PC_DAB_M3_STR-PR sy-vline
WA_GRPC_S_PC_DAB_M3_STR-PR_T sy-vline
WA_GRPC_S_PC_DAB_M3_STR-SP sy-vline
WA_GRPC_S_PC_DAB_M3_STR-SP_T sy-vline
WA_GRPC_S_PC_DAB_M3_STR-CN sy-vline
WA_GRPC_S_PC_DAB_M3_STR-CN_T sy-vline
WA_GRPC_S_PC_DAB_M3_STR-CN_SIG sy-vline
WA_GRPC_S_PC_DAB_M3_STR-CN_SIG_T sy-vline
WA_GRPC_S_PC_DAB_M3_STR-CN_EVIDENCE sy-vline
WA_GRPC_S_PC_DAB_M3_STR-CN_EVIDENCE_T sy-vline
WA_GRPC_S_PC_DAB_M3_STR-CN_CNTR_RISK sy-vline
WA_GRPC_S_PC_DAB_M3_STR-CN_CNTR_RISK_T sy-vline
WA_GRPC_S_PC_DAB_M3_STR-CN_TSTAUT sy-vline
WA_GRPC_S_PC_DAB_M3_STR-CN_TSTAUT_T sy-vline
WA_GRPC_S_PC_DAB_M3_STR-CD_RATING sy-vline
WA_GRPC_S_PC_DAB_M3_STR-CD_RATING_T sy-vline
WA_GRPC_S_PC_DAB_M3_STR-CD_DUE_DATE sy-vline
WA_GRPC_S_PC_DAB_M3_STR-CD_STATUS sy-vline
WA_GRPC_S_PC_DAB_M3_STR-CE_RATING sy-vline
WA_GRPC_S_PC_DAB_M3_STR-CE_RATING_T sy-vline
WA_GRPC_S_PC_DAB_M3_STR-CE_DUE_DATE sy-vline
WA_GRPC_S_PC_DAB_M3_STR-CE_STATUS sy-vline
WA_GRPC_S_PC_DAB_M3_STR-TE_RATING sy-vline
WA_GRPC_S_PC_DAB_M3_STR-TE_RATING_T sy-vline
WA_GRPC_S_PC_DAB_M3_STR-TE_DUE_DATE sy-vline
WA_GRPC_S_PC_DAB_M3_STR-TE_STATUS sy-vline
WA_GRPC_S_PC_DAB_M3_STR-RATING sy-vline
WA_GRPC_S_PC_DAB_M3_STR-RATING_T sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.