ABAP Select data from SAP table GRPC_S_UI_CONTROL_DATA into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP GRPC_S_UI_CONTROL_DATA table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to GRPC_S_UI_CONTROL_DATA. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the GRPC_S_UI_CONTROL_DATA table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_GRPC_S_UI_CONTROL_DATA TYPE STANDARD TABLE OF GRPC_S_UI_CONTROL_DATA, WA_GRPC_S_UI_CONTROL_DATA TYPE GRPC_S_UI_CONTROL_DATA, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <GRPC_S_UI_CONTROL_DATA> TYPE GRPC_S_UI_CONTROL_DATA. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_GRPC_S_UI_CONTROL_DATA. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM GRPC_S_UI_CONTROL_DATA INTO TABLE IT_GRPC_S_UI_CONTROL_DATA. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM GRPC_S_UI_CONTROL_DATA * INTO TABLE @DATA(IT_GRPC_S_UI_CONTROL_DATA2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_GRPC_S_UI_CONTROL_DATA INDEX 1 INTO DATA(WA_GRPC_S_UI_CONTROL_DATA2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_GRPC_S_UI_CONTROL_DATA ASSIGNING <GRPC_S_UI_CONTROL_DATA>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<GRPC_S_UI_CONTROL_DATA>-CONTROL_ID = 1.
<GRPC_S_UI_CONTROL_DATA>-SUBPROCESS_ID = 1.
<GRPC_S_UI_CONTROL_DATA>-ORGUNIT_ID = 1.
<GRPC_S_UI_CONTROL_DATA>-CONTROL_REF = 1.
<GRPC_S_UI_CONTROL_DATA>-SORT = 1.
ENDLOOP. LOOP AT IT_GRPC_S_UI_CONTROL_DATA INTO WA_GRPC_S_UI_CONTROL_DATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_GRPC_S_UI_CONTROL_DATA-TYP, sy-vline,
WA_GRPC_S_UI_CONTROL_DATA-IS_REFSTEP_DIFFERENT, sy-vline,
WA_GRPC_S_UI_CONTROL_DATA-REFERENCE, sy-vline,
WA_GRPC_S_UI_CONTROL_DATA-PRIOX, sy-vline,
WA_GRPC_S_UI_CONTROL_DATA-VALIDFROM, sy-vline,
WA_GRPC_S_UI_CONTROL_DATA-VALIDTO, sy-vline.
ENDLOOP. *Add any further fields from structure WA_GRPC_S_UI_CONTROL_DATA you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_GRPC_S_UI_CONTROL_DATA TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_GRPC_S_UI_CONTROL_DATA INTO WA_GRPC_S_UI_CONTROL_DATA. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_GRPC_S_UI_CONTROL_DATA_STR,
CONTROL_ID TYPE STRING,
SUBPROCESS_ID TYPE STRING,
ORGUNIT_ID TYPE STRING,
CONTROL_REF TYPE STRING,
SORT TYPE STRING,
TYP TYPE STRING,
IS_REFSTEP_DIFFERENT TYPE STRING,
REFERENCE TYPE STRING,
PRIOX TYPE STRING,
VALIDFROM TYPE STRING,
VALIDTO TYPE STRING,
CHANGED_ON TYPE STRING,
CHANGED_BY TYPE STRING,
DESCR TYPE STRING,
LTEXT TYPE STRING,
IS_CONTROL TYPE STRING,
_INPUT TYPE STRING,
_OUTPUT TYPE STRING,
AUTOM TYPE STRING,
AUTOM_DESCR TYPE STRING,
MAT_TAR TYPE STRING,
MAT_TAR_DESCR TYPE STRING,
NATURE TYPE STRING,
NATURE_DESCR TYPE STRING,
PURP TYPE STRING,
PURP_DESCR TYPE STRING,
SIG TYPE STRING,
SIG_DESCR TYPE STRING,
FREQ TYPE STRING,
TEST_AUTOM TYPE STRING,
DT_EVNT TYPE STRING,
EVENT_DESCR TYPE STRING,
TEST TYPE STRING,
TTECHNQ TYPE STRING,
TESTPROC TYPE STRING,
TESTPLAN_ID TYPE STRING,
SS_ORGUNIT TYPE STRING,
SS_ORGUNIT_DESCR TYPE STRING,
SHARED TYPE STRING,
TYP_TEXT TYPE STRING,
SOURCE TYPE STRING,
ORGUNIT_DESCR TYPE STRING,
PROCESS_DESCR TYPE STRING,
SUBPROCESS_DESCR TYPE STRING,END OF T_EKKO_STR. DATA: WA_GRPC_S_UI_CONTROL_DATA_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_GRPC_S_UI_CONTROL_DATA_STR-CONTROL_ID sy-vline
WA_GRPC_S_UI_CONTROL_DATA_STR-SUBPROCESS_ID sy-vline
WA_GRPC_S_UI_CONTROL_DATA_STR-ORGUNIT_ID sy-vline
WA_GRPC_S_UI_CONTROL_DATA_STR-CONTROL_REF sy-vline
WA_GRPC_S_UI_CONTROL_DATA_STR-SORT sy-vline
WA_GRPC_S_UI_CONTROL_DATA_STR-TYP sy-vline
WA_GRPC_S_UI_CONTROL_DATA_STR-IS_REFSTEP_DIFFERENT sy-vline
WA_GRPC_S_UI_CONTROL_DATA_STR-REFERENCE sy-vline
WA_GRPC_S_UI_CONTROL_DATA_STR-PRIOX sy-vline
WA_GRPC_S_UI_CONTROL_DATA_STR-VALIDFROM sy-vline
WA_GRPC_S_UI_CONTROL_DATA_STR-VALIDTO sy-vline
WA_GRPC_S_UI_CONTROL_DATA_STR-CHANGED_ON sy-vline
WA_GRPC_S_UI_CONTROL_DATA_STR-CHANGED_BY sy-vline
WA_GRPC_S_UI_CONTROL_DATA_STR-DESCR sy-vline
WA_GRPC_S_UI_CONTROL_DATA_STR-LTEXT sy-vline
WA_GRPC_S_UI_CONTROL_DATA_STR-IS_CONTROL sy-vline
WA_GRPC_S_UI_CONTROL_DATA_STR-_INPUT sy-vline
WA_GRPC_S_UI_CONTROL_DATA_STR-_OUTPUT sy-vline
WA_GRPC_S_UI_CONTROL_DATA_STR-AUTOM sy-vline
WA_GRPC_S_UI_CONTROL_DATA_STR-AUTOM_DESCR sy-vline
WA_GRPC_S_UI_CONTROL_DATA_STR-MAT_TAR sy-vline
WA_GRPC_S_UI_CONTROL_DATA_STR-MAT_TAR_DESCR sy-vline
WA_GRPC_S_UI_CONTROL_DATA_STR-NATURE sy-vline
WA_GRPC_S_UI_CONTROL_DATA_STR-NATURE_DESCR sy-vline
WA_GRPC_S_UI_CONTROL_DATA_STR-PURP sy-vline
WA_GRPC_S_UI_CONTROL_DATA_STR-PURP_DESCR sy-vline
WA_GRPC_S_UI_CONTROL_DATA_STR-SIG sy-vline
WA_GRPC_S_UI_CONTROL_DATA_STR-SIG_DESCR sy-vline
WA_GRPC_S_UI_CONTROL_DATA_STR-FREQ sy-vline
WA_GRPC_S_UI_CONTROL_DATA_STR-TEST_AUTOM sy-vline
WA_GRPC_S_UI_CONTROL_DATA_STR-DT_EVNT sy-vline
WA_GRPC_S_UI_CONTROL_DATA_STR-EVENT_DESCR sy-vline
WA_GRPC_S_UI_CONTROL_DATA_STR-TEST sy-vline
WA_GRPC_S_UI_CONTROL_DATA_STR-TTECHNQ sy-vline
WA_GRPC_S_UI_CONTROL_DATA_STR-TESTPROC sy-vline
WA_GRPC_S_UI_CONTROL_DATA_STR-TESTPLAN_ID sy-vline
WA_GRPC_S_UI_CONTROL_DATA_STR-SS_ORGUNIT sy-vline
WA_GRPC_S_UI_CONTROL_DATA_STR-SS_ORGUNIT_DESCR sy-vline
WA_GRPC_S_UI_CONTROL_DATA_STR-SHARED sy-vline
WA_GRPC_S_UI_CONTROL_DATA_STR-TYP_TEXT sy-vline
WA_GRPC_S_UI_CONTROL_DATA_STR-SOURCE sy-vline
WA_GRPC_S_UI_CONTROL_DATA_STR-ORGUNIT_DESCR sy-vline
WA_GRPC_S_UI_CONTROL_DATA_STR-PROCESS_DESCR sy-vline
WA_GRPC_S_UI_CONTROL_DATA_STR-SUBPROCESS_DESCR sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.