ABAP Select data from SAP table GRPC_SREP_OUT_F10 into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP GRPC_SREP_OUT_F10 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to GRPC_SREP_OUT_F10. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the GRPC_SREP_OUT_F10 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_GRPC_SREP_OUT_F10 TYPE STANDARD TABLE OF GRPC_SREP_OUT_F10, WA_GRPC_SREP_OUT_F10 TYPE GRPC_SREP_OUT_F10, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <GRPC_SREP_OUT_F10> TYPE GRPC_SREP_OUT_F10. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_GRPC_SREP_OUT_F10. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM GRPC_SREP_OUT_F10 INTO TABLE IT_GRPC_SREP_OUT_F10. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM GRPC_SREP_OUT_F10 * INTO TABLE @DATA(IT_GRPC_SREP_OUT_F102). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_GRPC_SREP_OUT_F10 INDEX 1 INTO DATA(WA_GRPC_SREP_OUT_F102). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_GRPC_SREP_OUT_F10 ASSIGNING <GRPC_SREP_OUT_F10>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<GRPC_SREP_OUT_F10>-TESTSTEP_SEQNR = 1.
<GRPC_SREP_OUT_F10>-TEST_STEP_DESC = 1.
<GRPC_SREP_OUT_F10>-IS_TEST = 1.
<GRPC_SREP_OUT_F10>-IS_TEST_T = 1.
<GRPC_SREP_OUT_F10>-REQUIRED = 1.
ENDLOOP. LOOP AT IT_GRPC_SREP_OUT_F10 INTO WA_GRPC_SREP_OUT_F10. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_GRPC_SREP_OUT_F10-REQUIRED_T, sy-vline,
WA_GRPC_SREP_OUT_F10-FAIL_TEST, sy-vline,
WA_GRPC_SREP_OUT_F10-FAIL_TEST_T, sy-vline,
WA_GRPC_SREP_OUT_F10-INITIAL_SAMPLE, sy-vline,
WA_GRPC_SREP_OUT_F10-SAMPLING_METHOD, sy-vline,
WA_GRPC_SREP_OUT_F10-SAMPLING_METHOD_T, sy-vline.
ENDLOOP. *Add any further fields from structure WA_GRPC_SREP_OUT_F10 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_GRPC_SREP_OUT_F10 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_GRPC_SREP_OUT_F10 INTO WA_GRPC_SREP_OUT_F10. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
*Conversion exit ALPHA, internal->external for field INITIAL_SAMPLE CALL FUNCTION 'CONVERSION_EXIT_ALPHA_OUTPUT' EXPORTING input = WA_GRPC_SREP_OUT_F10-INITIAL_SAMPLE IMPORTING output = ld_input.
WRITE:/ 'Org Value:', WA_GRPC_SREP_OUT_F10-INITIAL_SAMPLE.
WRITE:/ 'New Value:', ld_input.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_GRPC_SREP_OUT_F10_STR,
TESTSTEP_SEQNR TYPE STRING,
TEST_STEP_DESC TYPE STRING,
IS_TEST TYPE STRING,
IS_TEST_T TYPE STRING,
REQUIRED TYPE STRING,
REQUIRED_T TYPE STRING,
FAIL_TEST TYPE STRING,
FAIL_TEST_T TYPE STRING,
INITIAL_SAMPLE TYPE STRING,
SAMPLING_METHOD TYPE STRING,
SAMPLING_METHOD_T TYPE STRING,
REVISED_SAMPLE TYPE STRING,
NUM_FAILED TYPE STRING,
RESULT_TS TYPE STRING,
COMMENT_TS TYPE STRING,
NAME TYPE STRING,
STEP_RESULT_T TYPE STRING,
ORGUNIT TYPE STRING,
ORGUNIT_T TYPE STRING,
ORGUNIT_D TYPE STRING,
PRGROUP TYPE STRING,
PRGROUP_T TYPE STRING,
PRGROUP_D TYPE STRING,
PROCESS TYPE STRING,
PROCESS_T TYPE STRING,
PROCESS_D TYPE STRING,
CONTROL TYPE STRING,
CONTROL_T TYPE STRING,
CONTROL_D TYPE STRING,
CONTROL_TSTAUT_T TYPE STRING,END OF T_EKKO_STR. DATA: WA_GRPC_SREP_OUT_F10_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_GRPC_SREP_OUT_F10_STR-TESTSTEP_SEQNR sy-vline
WA_GRPC_SREP_OUT_F10_STR-TEST_STEP_DESC sy-vline
WA_GRPC_SREP_OUT_F10_STR-IS_TEST sy-vline
WA_GRPC_SREP_OUT_F10_STR-IS_TEST_T sy-vline
WA_GRPC_SREP_OUT_F10_STR-REQUIRED sy-vline
WA_GRPC_SREP_OUT_F10_STR-REQUIRED_T sy-vline
WA_GRPC_SREP_OUT_F10_STR-FAIL_TEST sy-vline
WA_GRPC_SREP_OUT_F10_STR-FAIL_TEST_T sy-vline
WA_GRPC_SREP_OUT_F10_STR-INITIAL_SAMPLE sy-vline
WA_GRPC_SREP_OUT_F10_STR-SAMPLING_METHOD sy-vline
WA_GRPC_SREP_OUT_F10_STR-SAMPLING_METHOD_T sy-vline
WA_GRPC_SREP_OUT_F10_STR-REVISED_SAMPLE sy-vline
WA_GRPC_SREP_OUT_F10_STR-NUM_FAILED sy-vline
WA_GRPC_SREP_OUT_F10_STR-RESULT_TS sy-vline
WA_GRPC_SREP_OUT_F10_STR-COMMENT_TS sy-vline
WA_GRPC_SREP_OUT_F10_STR-NAME sy-vline
WA_GRPC_SREP_OUT_F10_STR-STEP_RESULT_T sy-vline
WA_GRPC_SREP_OUT_F10_STR-ORGUNIT sy-vline
WA_GRPC_SREP_OUT_F10_STR-ORGUNIT_T sy-vline
WA_GRPC_SREP_OUT_F10_STR-ORGUNIT_D sy-vline
WA_GRPC_SREP_OUT_F10_STR-PRGROUP sy-vline
WA_GRPC_SREP_OUT_F10_STR-PRGROUP_T sy-vline
WA_GRPC_SREP_OUT_F10_STR-PRGROUP_D sy-vline
WA_GRPC_SREP_OUT_F10_STR-PROCESS sy-vline
WA_GRPC_SREP_OUT_F10_STR-PROCESS_T sy-vline
WA_GRPC_SREP_OUT_F10_STR-PROCESS_D sy-vline
WA_GRPC_SREP_OUT_F10_STR-CONTROL sy-vline
WA_GRPC_SREP_OUT_F10_STR-CONTROL_T sy-vline
WA_GRPC_SREP_OUT_F10_STR-CONTROL_D sy-vline
WA_GRPC_SREP_OUT_F10_STR-CONTROL_TSTAUT_T sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.