ABAP Select data from SAP table HCMT_BSP_PA_HU_R3264 into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP HCMT_BSP_PA_HU_R3264 table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to HCMT_BSP_PA_HU_R3264. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the HCMT_BSP_PA_HU_R3264 table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_HCMT_BSP_PA_HU_R3264 TYPE STANDARD TABLE OF HCMT_BSP_PA_HU_R3264, WA_HCMT_BSP_PA_HU_R3264 TYPE HCMT_BSP_PA_HU_R3264, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <HCMT_BSP_PA_HU_R3264> TYPE HCMT_BSP_PA_HU_R3264. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_HCMT_BSP_PA_HU_R3264. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM HCMT_BSP_PA_HU_R3264 INTO TABLE IT_HCMT_BSP_PA_HU_R3264. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM HCMT_BSP_PA_HU_R3264 * INTO TABLE @DATA(IT_HCMT_BSP_PA_HU_R32642). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_HCMT_BSP_PA_HU_R3264 INDEX 1 INTO DATA(WA_HCMT_BSP_PA_HU_R32642). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_HCMT_BSP_PA_HU_R3264 ASSIGNING <HCMT_BSP_PA_HU_R3264>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<HCMT_BSP_PA_HU_R3264>-OBJECT_KEY = 1.
<HCMT_BSP_PA_HU_R3264>-PERNR = 1.
<HCMT_BSP_PA_HU_R3264>-AEDTM = 1.
<HCMT_BSP_PA_HU_R3264>-UNAME = 1.
<HCMT_BSP_PA_HU_R3264>-SPRPS = 1.
ENDLOOP. LOOP AT IT_HCMT_BSP_PA_HU_R3264 INTO WA_HCMT_BSP_PA_HU_R3264. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_HCMT_BSP_PA_HU_R3264-SPRTX, sy-vline,
WA_HCMT_BSP_PA_HU_R3264-ITBLD, sy-vline,
WA_HCMT_BSP_PA_HU_R3264-ITXEX, sy-vline,
WA_HCMT_BSP_PA_HU_R3264-BEGDA, sy-vline,
WA_HCMT_BSP_PA_HU_R3264-ENDDA, sy-vline,
WA_HCMT_BSP_PA_HU_R3264-SUBTYTXT, sy-vline.
ENDLOOP. *Add any further fields from structure WA_HCMT_BSP_PA_HU_R3264 you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_HCMT_BSP_PA_HU_R3264 TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_HCMT_BSP_PA_HU_R3264 INTO WA_HCMT_BSP_PA_HU_R3264. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_HCMT_BSP_PA_HU_R3264_STR,
OBJECT_KEY TYPE STRING,
PERNR TYPE STRING,
AEDTM TYPE STRING,
UNAME TYPE STRING,
SPRPS TYPE STRING,
SPRTX TYPE STRING,
ITBLD TYPE STRING,
ITXEX TYPE STRING,
BEGDA TYPE STRING,
ENDDA TYPE STRING,
SUBTYTXT TYPE STRING,
VITYP TYPE STRING,
VIZSGSZ TYPE STRING,
VIZSGSZTXT TYPE STRING,
OKMSZM TYPE STRING,
VIZSEDAT TYPE STRING,
NYILSZ TYPE STRING,
LEADAT TYPE STRING,
VONDAT TYPE STRING,
JOGCIM TYPE STRING,
JOGCIMTXT TYPE STRING,
IKTSZ TYPE STRING,
LEADB TYPE STRING,
GYAKO TYPE STRING,
KOVNYES TYPE STRING,
ESEM TYPE STRING,
ESEMTXT TYPE STRING,
ESDAT TYPE STRING,
VIZSSOR TYPE STRING,
VIZSKEZD TYPE STRING,
VIZSBEF TYPE STRING,
VIZSJOGC TYPE STRING,
VIZSJOGCTXT TYPE STRING,
VIEREDM TYPE STRING,
VIEREDMTXT TYPE STRING,
VIGYAKO TYPE STRING,
KOVVIES TYPE STRING,END OF T_EKKO_STR. DATA: WA_HCMT_BSP_PA_HU_R3264_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_HCMT_BSP_PA_HU_R3264_STR-OBJECT_KEY sy-vline
WA_HCMT_BSP_PA_HU_R3264_STR-PERNR sy-vline
WA_HCMT_BSP_PA_HU_R3264_STR-AEDTM sy-vline
WA_HCMT_BSP_PA_HU_R3264_STR-UNAME sy-vline
WA_HCMT_BSP_PA_HU_R3264_STR-SPRPS sy-vline
WA_HCMT_BSP_PA_HU_R3264_STR-SPRTX sy-vline
WA_HCMT_BSP_PA_HU_R3264_STR-ITBLD sy-vline
WA_HCMT_BSP_PA_HU_R3264_STR-ITXEX sy-vline
WA_HCMT_BSP_PA_HU_R3264_STR-BEGDA sy-vline
WA_HCMT_BSP_PA_HU_R3264_STR-ENDDA sy-vline
WA_HCMT_BSP_PA_HU_R3264_STR-SUBTYTXT sy-vline
WA_HCMT_BSP_PA_HU_R3264_STR-VITYP sy-vline
WA_HCMT_BSP_PA_HU_R3264_STR-VIZSGSZ sy-vline
WA_HCMT_BSP_PA_HU_R3264_STR-VIZSGSZTXT sy-vline
WA_HCMT_BSP_PA_HU_R3264_STR-OKMSZM sy-vline
WA_HCMT_BSP_PA_HU_R3264_STR-VIZSEDAT sy-vline
WA_HCMT_BSP_PA_HU_R3264_STR-NYILSZ sy-vline
WA_HCMT_BSP_PA_HU_R3264_STR-LEADAT sy-vline
WA_HCMT_BSP_PA_HU_R3264_STR-VONDAT sy-vline
WA_HCMT_BSP_PA_HU_R3264_STR-JOGCIM sy-vline
WA_HCMT_BSP_PA_HU_R3264_STR-JOGCIMTXT sy-vline
WA_HCMT_BSP_PA_HU_R3264_STR-IKTSZ sy-vline
WA_HCMT_BSP_PA_HU_R3264_STR-LEADB sy-vline
WA_HCMT_BSP_PA_HU_R3264_STR-GYAKO sy-vline
WA_HCMT_BSP_PA_HU_R3264_STR-KOVNYES sy-vline
WA_HCMT_BSP_PA_HU_R3264_STR-ESEM sy-vline
WA_HCMT_BSP_PA_HU_R3264_STR-ESEMTXT sy-vline
WA_HCMT_BSP_PA_HU_R3264_STR-ESDAT sy-vline
WA_HCMT_BSP_PA_HU_R3264_STR-VIZSSOR sy-vline
WA_HCMT_BSP_PA_HU_R3264_STR-VIZSKEZD sy-vline
WA_HCMT_BSP_PA_HU_R3264_STR-VIZSBEF sy-vline
WA_HCMT_BSP_PA_HU_R3264_STR-VIZSJOGC sy-vline
WA_HCMT_BSP_PA_HU_R3264_STR-VIZSJOGCTXT sy-vline
WA_HCMT_BSP_PA_HU_R3264_STR-VIEREDM sy-vline
WA_HCMT_BSP_PA_HU_R3264_STR-VIEREDMTXT sy-vline
WA_HCMT_BSP_PA_HU_R3264_STR-VIGYAKO sy-vline
WA_HCMT_BSP_PA_HU_R3264_STR-KOVVIES sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.