ABAP Select data from SAP table HIT_CMP_AUS into internal table
Get Example source ABAP code based on a different SAP table
Below is a number of ABAP code snippets to demonstrate how to select data from SAP HIT_CMP_AUS table and store it within an internal table, including using the newer @DATA inline declaration methods. It also shows you various ways to process this data using ABAP work area, inline declaration or field symbols including executing all the relevant CONVERSION_EXIT routines specific to HIT_CMP_AUS. See here for more generic Select statement tips.
Sometimes data within SAP is stored within the database table in a different format to what it is displayed to the user. These input/output conversation FM routines are what translates the data between the two formats.
There is also a full declaration of the HIT_CMP_AUS table where each field has a char/string type for you to simply copy and paste. This allows you to use processing that is only available to these field types such as the CONCATENATE statement.
DATA: IT_HIT_CMP_AUS TYPE STANDARD TABLE OF HIT_CMP_AUS, WA_HIT_CMP_AUS TYPE HIT_CMP_AUS, GD_STR TYPE STRING. DATA: lo_typedescr type REF TO cl_abap_typedescr. DATA: lv_fieldname type fieldname. FIELD-SYMBOLS: <FIELD> TYPE any. FIELD-SYMBOLS: <HIT_CMP_AUS> TYPE HIT_CMP_AUS. *Process all fields in table header/work area as string values PERFORM process_as_string_field_values CHANGING wa_HIT_CMP_AUS. SELECT * *restrict ABAP select to first 10 rows UP TO 10 ROWS FROM HIT_CMP_AUS INTO TABLE IT_HIT_CMP_AUS. *Select data and declare internal table using in-line method @DATA *SELECT * * FROM HIT_CMP_AUS * INTO TABLE @DATA(IT_HIT_CMP_AUS2). *--Further methods of using ABAP code to select data from SAP database tables *You can also declare the header/work area using the in-line DATA declaration method READ TABLE IT_HIT_CMP_AUS INDEX 1 INTO DATA(WA_HIT_CMP_AUS2). *Demonstrate how to loop at an internal table and update values using a FIELD-SYMBOL LOOP AT IT_HIT_CMP_AUS ASSIGNING <HIT_CMP_AUS>.*To update a field value using a field symbol simply change the value via the field symbol pointer
<HIT_CMP_AUS>-ID = 1.
<HIT_CMP_AUS>-SUBID = 1.
<HIT_CMP_AUS>-EVENTNAME = 1.
<HIT_CMP_AUS>-PROG = 1.
<HIT_CMP_AUS>-CODE = 1.
ENDLOOP. LOOP AT IT_HIT_CMP_AUS INTO WA_HIT_CMP_AUS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Write selected data to screen/report before conversion. WRITE:/ sy-vline, WA_HIT_CMP_AUS-EXECS_R21, sy-vline,
WA_HIT_CMP_AUS-EXECS_D21, sy-vline,
WA_HIT_CMP_AUS-EXECS2, sy-vline,
WA_HIT_CMP_AUS-EXECS1, sy-vline,
WA_HIT_CMP_AUS-GROSS_R21, sy-vline,
WA_HIT_CMP_AUS-GROSS_D21, sy-vline.
ENDLOOP. *Add any further fields from structure WA_HIT_CMP_AUS you want to display... WRITE:/ sy-uline. * Aternatively use generic code to Write field values (and NAME) to screen report DO. ASSIGN COMPONENT sy-index OF STRUCTURE wa_HIT_CMP_AUS TO <field>. IF sy-subrc <> 0. EXIT. ENDIF. WRITE:/ 'Field Value', <field>, sy-vline. gd_str = <field> . lo_typedescr ?= CL_ABAP_DATADESCR=>DESCRIBE_BY_DATA( <field> ). lv_fieldname = lo_typedescr->GET_RELATIVE_NAME( ). WRITE:/ 'Field Name', lv_fieldname. ENDDO. *Redo loop but convert all fields from internal to out value LOOP AT IT_HIT_CMP_AUS INTO WA_HIT_CMP_AUS. *Write horizonal line to screen report. WRITE:/ sy-uline. *Convert all fields to display/output versions using conversion routines PERFORM convert_all_field_values CHANGING wa_EKKO. ENDLOOP. *&---------------------------------------------------------------------* *& Form convert_all_field_values *&---------------------------------------------------------------------* FORM convert_all_field_values CHANGING p_EKKO LIKE wa_EKKO. DATA: ld_input(1000) TYPE c, ld_output(1000) TYPE C.
ENDFORM. *&---------------------------------------------------------------------* *& Form process_as_string_field_values *&---------------------------------------------------------------------* FORM process_as_string_field_values CHANGING p_EKKO LIKE wa_EKKO. TYPES: BEGIN OF T_HIT_CMP_AUS_STR,
ID TYPE STRING,
SUBID TYPE STRING,
EVENTNAME TYPE STRING,
PROG TYPE STRING,
CODE TYPE STRING,
EXECS_R21 TYPE STRING,
EXECS_D21 TYPE STRING,
EXECS2 TYPE STRING,
EXECS1 TYPE STRING,
GROSS_R21 TYPE STRING,
GROSS_D21 TYPE STRING,
GROSS2 TYPE STRING,
GROSS1 TYPE STRING,
NET_R21 TYPE STRING,
NET_D21 TYPE STRING,
NET2 TYPE STRING,
NET1 TYPE STRING,
EXTRA TYPE STRING,END OF T_EKKO_STR. DATA: WA_HIT_CMP_AUS_STR type T_EKKO_STR. DATA: ld_text TYPE string. LOOP AT IT_EKKO INTO WA_EKKO. MOVE-CORRESPONDING wa_EKKO TO WA_EKKO_STR. CONCATENATE: sy-vline
WA_HIT_CMP_AUS_STR-ID sy-vline
WA_HIT_CMP_AUS_STR-SUBID sy-vline
WA_HIT_CMP_AUS_STR-EVENTNAME sy-vline
WA_HIT_CMP_AUS_STR-PROG sy-vline
WA_HIT_CMP_AUS_STR-CODE sy-vline
WA_HIT_CMP_AUS_STR-EXECS_R21 sy-vline
WA_HIT_CMP_AUS_STR-EXECS_D21 sy-vline
WA_HIT_CMP_AUS_STR-EXECS2 sy-vline
WA_HIT_CMP_AUS_STR-EXECS1 sy-vline
WA_HIT_CMP_AUS_STR-GROSS_R21 sy-vline
WA_HIT_CMP_AUS_STR-GROSS_D21 sy-vline
WA_HIT_CMP_AUS_STR-GROSS2 sy-vline
WA_HIT_CMP_AUS_STR-GROSS1 sy-vline
WA_HIT_CMP_AUS_STR-NET_R21 sy-vline
WA_HIT_CMP_AUS_STR-NET_D21 sy-vline
WA_HIT_CMP_AUS_STR-NET2 sy-vline
WA_HIT_CMP_AUS_STR-NET1 sy-vline
WA_HIT_CMP_AUS_STR-EXTRA sy-vline INTO ld_text SEPARATED BY SPACE. *Add any further fields from structure WA_EKKO_STR you want to CONCATENATE... ENDLOOP. ENDFORM.